Enter/Exit Programming Mode
124
PowerScan™ PD9530/PBT9500/PM9500
I 2 of 5 Check Character Calculation
This option enables/disables calculation and verification of an optional I 2 of
5 check character
.
Combinations of these settings are possible via the Alad-
din configuration utility, or contact Technical Support.
DEFAULT
$CI2CC00(CR)
I 2 of 5 Check Character Calculation = Disable
$CI2CC01(CR)
I 2 of 5 Check Character Calculation = Check Standard
(Modulo 10)
$CI2CC02(CR)
I 2 of 5 Check Character Calculation = Check German Parcel
$CI2CC04(CR)
I 2 of 5 Check Character Calculation = Check DHL
$CI2CC08(CR)
I 2 of 5 Check Character Calculation = Check Daimler Chrys-
ler
$CI2CC10(CR)
I 2 of 5 Check Character Calculation = Check Bosch
$CI2CC20(CR)
I 2 of 5 Check Character Calculation = Italian Post