background image

Default Configuration

Quick Reference Guide

15

Default Configuration

DATA FORMAT – Symbology Dependent Parameters

symbology specific format = select all, no headers, no terminators, symbology character
substitution disabled, symbology character deletion disabled

DATA FORMAT – Concatenation

Concatenation disabled, 2 EAN/UPC codes concatenated, Set First Concatenated Code
Length 000 = any length, Set Second Concatenated Code Length 000 = any length, Set
Third Concatenated Code Length 000 = any length, Set Fourth Concatenated Code Length
000 = any length, Concatenation with Intercode Delay disabled, Concatenation Timeout 10
seconds, Concatenation Failure Transmission = Tx codes causing failure, Transmission after
Timeout = No code transmission, Concatenation Result Code ID = No code Identifier

ADVANCED FORMATTING PARAMETERS

format disabled

CAMERA CONTROL

exposure mode = automatic, based on entire image

CODE SELECTION

issue identical codes = enable

enabled codes

Standard Code 39: no check digit control, variable code length;

EAN 8/EAN 13 / UPC A/UPC E without ADD ON: UPCE expansion disabled

Code 128: variable code length

PDF417
Datamatrix: rectangular, normal and inverted, variable code length
QR

disabled codes

Code 32, Interleaved 2/5, Codabar, Code 93, EAN 128, GS1 DataBar™, Micro PDF417, Postal
Codes, Maxicode, Composite Codes

Aztec, microQR, IMB.

READING PARAMETERS

trigger type normal, trigger level mode, flash on = 2 sec, flash off = 2 sec, beeper tone =
tone 1, beeper volume = high, beeper duration = 50 ms, user defined beeper = tone 1, user
defined beeper volume = high, user defined beeper duration = 100 ms, code per scan = one
code per scan, read per cycle = one read per cycle, scan timeout = 5 sec, central code
transmission = disabled, order by code length = disabled, order by code symbology =
disabled, autoscan mode = disabled, autoscan aiming system = enabled, autoscan
hardware trigger = enabled, autoscan illumination system = disabled, stand autoscan mode
= normal, aiming system delay = disabled, good read spot = short, safety time = 500 ms

RADIO PARAMETERS

radio protocol timeout = 2 seconds, power-off timeout = 4 hours, transmission mode =
one-way, beeper control for radio response = normal, single store = disabled, batch mode =
disabled, find me = enabled, radio RX timeout = disabled 

Содержание PowerScan M8500

Страница 1: ...PowerScan M8500 Readers Industrial Handheld Area Imager Bar Code Reader with Datalogic s STAR Cordless System Quick Reference Guide...

Страница 2: ...website www datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggestions about this or other Datalogic publications please let us know via th...

Страница 3: ...Scan M8500 BC 80X0 Stand Alone Setup 8 Using Multiple Readers with Same Cradle 11 PowerScan M8500 STAR MODEM Stand Alone Setup 11 PowerScan M8500 STAR SYSTEM Setup 12 Default Configuration 15 Operatin...

Страница 4: ...NOTES...

Страница 5: ...0 reliably decodes all major 1D linear bar codes 2D stacked codes such as PDF417 2D matrix symbols such as DataMatrix postal codes such as POSTNET PLANET The data stream acquired from decoding a symbo...

Страница 6: ...es size as you move the reader closer or farther away from the code Relative Size and Location of Aiming System Pattern Successful reading is signaled by an audible tone plus a good read green LED The...

Страница 7: ...vailable on the website The application program can also manage the beeper User Defined Beeper when the reader is controlled by a Host PC It is possible to activate the beeper by send ing a command fr...

Страница 8: ...r The Reader LED on the cradle battery charger turns red The battery is completely charged when the Reader LED on the cradle battery charger turns green To change the battery push the Release Button a...

Страница 9: ...place the battery pack in fire or heat Donotconnectthepositiveterminalandnegativeterminalofthebatterypack to each other with any metal object such as wire Do not carry or store the battery pack toget...

Страница 10: ...e to the Host For installation and connection information see the BC 80X0 Quick Reference Manual 2 Charge the PowerScan M8500 battery using an BC 80X0 or the C 8000 charger as described in this Quick...

Страница 11: ...sses To rapidly configure your point to point application 1 Apply the bind address label onto the BC 80X0 base station as indicated in the BC 80X0 Quick Reference Manual 2 When the BC 80X0 cradle is c...

Страница 12: ...ered configure the PowerScan M8500 by reading the following codes in the given sequence and follow the instruc tions For the numeric code selection of steps 3 4 and 5 use the table at the end of this...

Страница 13: ...he BC 80X0 cradle The reader is dedicated to the cradle Any previously bound reader will be excluded To connect several readers to the same cradle see the following section Using Multiple Readers with...

Страница 14: ...PowerScan M8500 Configuration 10 PowerScan M8500 END of procedure YOUR READER IS NOW READYTO READ CODES 9 Configure the BC 80X0 cradle refer to the BC 80X0 Quick Reference Green LED...

Страница 15: ...e PowerScan M8500 STAR MODEM Stand Alone Setup To configure a PowerScan M8500 reader to communicate with STAR Modem in Stand Alone Mode follow the PowerScan M8500 BC 80X0 Stand Alone Setup procedure s...

Страница 16: ...g procedure allows configuring a PowerScan M8500 reader to communicate with various STAR System devices such as Stargate RF base stations 1 Restore PowerScan M8500 Default 2 Enter Configuration 3 Set...

Страница 17: ...Characters Code Length 240 Characters not for systems with BC 80X0 as Master 6 Set Radio Address four digits from the Numeric Table for the PowerScan M8500 Address from 0000 to 1999 All readers used...

Страница 18: ...OW READY TO READ CODES 8 Set Last STAR System Address four digits from the Numeric Table in the range 0000 to 1999 Whenever the system is composed of a single base station the first and last base stat...

Страница 19: ...gth EAN 8 EAN 13 UPC A UPC E without ADD ON UPCE expansion disabled Code 128 variable code length PDF417 Datamatrix rectangular normal and inverted variable code length QR disabled codes Code 32 Inter...

Страница 20: ...Operating Test 16 PowerScan M8500 Operating Test EAN 13 Code 39 Standard Code 128 PDF417 QR Data Matrix Normal 1 234567 000992 1 7 1 6 2 t e s t...

Страница 21: ...30 m System Configuration BC 80X0 STARGATE Max number of devices per base station 32 Max number of devices in the same reading area 2000 Environmental Features Operating Temperature 10 to 50 C 14 to...

Страница 22: ...tical Features Sensor 1280 x 1024 pixel element 2D CMOS Array Illuminator LED array Wavelength In the range 630 670 nm LED Safety Class Class 1 to EN 60825 1 Aiming System Visible Laser Diode Waveleng...

Страница 23: ...Resolution Linear codes mm mils PDF417 mm mils Datamatrix mm mils 0 10 4 0 10 4 0 17 6 6 Depth of field 1D linear X dimension mm mils DOF cm in Code39 0 13 5 7 5 to 15 5 2 95 to 6 10 0 5 20 5 5 to 36...

Страница 24: ...05 2 mils 0 08 3 mils 0 10 4 mils Depth of field 1D linear X dimension mm mils DOF cm in Code39 0 08 3 4 5 to 8 0 1 77 to 3 15 0 13 5 3 5 to 9 5 1 38 to 3 74 0 51 20 6 0 to 18 5 2 36 to 7 28 EAN13 0...

Страница 25: ...n Linear codes mm mils PDF 417 mm mils Datamatrix mm mils 0 13 5 mils 0 13 5 mils 0 19 7 5 mils Depth of field 1D linear X dimension mm mils DOF cm in Code39 0 13 5 2 5 to 10 0 0 98 to 3 94 0 51 20 1...

Страница 26: ...ing Datalogic Aladdin a multi platform utility program that allows device configuration using a PC It provides RS 232 interface configuration as well as configuration bar code printing Service Support...

Страница 27: ...is device must accept any interference received including interference which may cause undesired operation FCC ID U4F0015 Radio Compliance Contact the competent authority responsible for the managemen...

Страница 28: ...as en Argentina El uso de fuentes de alimentaci n no compatibles puede resultar en riesgo de incendio o de choque el ctrico para el usuario Este Producto es usable en Mexico Certificado Nr RCPDAST08 0...

Страница 29: ...01 07898916345031 Modelo PowerScan M8500 BC8060 and BC8030 carregadores Este equipamento opera em car ter secund rio isto n o tem direito a prote o contra interfer ncia prejudicial mesmo de esta es d...

Страница 30: ...lements Scanner Lead Pb Mercury Hg Cadmium Cd Hexavalent Chromium Cr VI Polybrominated biphenyls PBB Polybrominated diphenyl ethers PBDE PART Printed Circuit Board Assembly X O O O O O Assy Optics Blo...

Страница 31: ...ble of Restricted Elements Base Lead Pb Mercury Hg Cadmium Cd Hexavalent Chromium Cr VI Polybrominated biphenyls PBB Polybrominated diphenyl ethers PBDE PART Printed Circuit Board Assembly X O O O O O...

Страница 32: ...IST F R DAS MENSCHLICHE AUGE SICHTBARUNDWIRD AM STRAHLAUS TRITTSFENSTER AUS GESENDET SIEHE BILD LE RAYON LASER EST VISIBLE L OEIL NU ET IL EST MIS PAR LA FEN TRE D SIGN E SUR L ILLUSTRATION DANS LA FI...

Страница 33: ...esto prodotto risulta conforme alle normative vigenti sulla sicurezza laser alla data di produzione CDRH 21 CFR 1040 e EN 60825 1 Non si rende mai necessario aprire l appa recchio per motivi di instal...

Страница 34: ...CDRH 21 CFR 1040 et EN 60825 1 Il n est pas n cessaire d ouvrir l appareil pour l installation l utilisation ou l entre tien Le produit utilise une diode laser Aucun dommage aux yeux humains n a t co...

Страница 35: ...though staring directly at the laser beam momentarily causes no known biological damage avoid staring at the beam as one would with any very strong light source such as the sun Avoid that the laser be...

Страница 36: ...datalogic com German Informationen zur Entsorgung von Elektro und Elektronik Altger ten WEEE erhalten Sie auf der Webseite www datalogic com Spanish Si desea informaci n acerca de los procedimientos p...

Страница 37: ...ogic for the duration published by Datalogic for the product at the time of purchase Warranty period Datalogic warrants repaired hardware devices against defects in workmanship and materials on the re...

Страница 38: ...other instrument equipment or apparatus iv any claimed defect or damage caused by the failure to provide proper maintenance including but not limited to cleaning the upper window in accordance with pr...

Страница 39: ...ER S SOLE AND EXCLU SIVE REMEDY FOR WARRANTY CLAIMS UNDER NO CIRCUM STANCES WILL DATALOGIC BE LIABLE TO CUSTOMER OR ANY THIRD PARTY FOR ANY LOST PROFITS OR ANY INCIDENTAL CON SEQUENTIAL IN DIRECT SPEC...

Страница 40: ...DLDLLLDDLDDLLLLDDDLDDLDLLL 2 ANEOGIFKDNGNENEIEPANHOGOCK AHPNIBAMDKEOFMHMLJAKEFGHIK AKCBPJCJGIIJCMCEGMILJPPDNK AEFBJLBGMHPKMKEKGKAMOGNEGK AAPHBAJJDEFNLJHLIGJCCKKLDK AELEBMKKGLEGCCHPLDIKICJLLK DDLLLLDD...

Страница 41: ...LLLDDDDDLLLLDDDDDDLDLDL 7 ANFNGIFKDNGNENEIEPANHOGOCK AHPNIBAMDKEOFMHMLJAKFCHFIK AKCBPJCJGIIJCMCEHJLAGJEHJK AEFBJLBGMHPKMMHJBODNLMGFGK AAPHBAJIDFBCOHNDCJGDNMAPDK AHKEBNOMACIOMCLCEECKCIFKLK DDLLLLDDDDLL...

Страница 42: ...Numeric Table 38 PowerScan M8500 NOTES...

Страница 43: ...rt darauf da das Produkt den folgenden Normen entspricht Esta declaraci n se basa en el cumplimiento de los productos con las siguientes normas Datalogic ADC Srl Via S Vitalino 13 Lippo di Calderara d...

Страница 44: ...alogic Inc All rights reserved Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U Datalogic ADC Inc 959 Terry Street Eugene...

Отзывы: