CONFIGURATION
33
4.7
BC-8060 STAR-SYSTEM™ NETWORK SETUP
When the BC-8060 cradle model is used in an RS-485 network, it must be initially
configured. To do this using configuration barcodes, follow the procedure below
using any PowerScan
®
M8300 reader.
1.
Set BC-8060 Address
Ì$+RF4Î
+
four digits for the BC-8060 Address (from
0000
to
1999
).
All cradles used in the network must have different addresses.
2.
Exit and Save configuration
Ì$-?Î
3.
Read the
Bind
code to pair the PowerScan
®
M8300 to the BC-8060 cradle for
configuration.
Bind
Ì$+RN0$-IÎ
The green LED on the PowerScan
®
M8300 will blink; the reader is ready to be
inserted into the cradle.
4.
Firmly insert the reader into the BC-8060 cradle within 10 seconds, a beep will
be emitted, signaling that the BC-8060 cradle has been paired to the
PowerScan
®
M8300, and the green LED on the reader will go off.
green LED