CONFIGURATION
31
4.6
POWERSCAN
®
M8300/STAR-SYSTEM™ SETUP
The following procedure allows configuring a PowerScan
®
M8300 reader to
communicate with various STAR-System™ devices such as STARGATE™ RF base
stations.
1.
Restore PowerScan
®
M8300 Default
Ì$+$*oÎ
2.
Enter Configuration
Ì$+;Î
3.
Set Date
ÌIA%Î
+
six digits for Day, Month and Year (DDMMYY)
4.
Set Time
ÌIB'Î
+
four digits for Hour and Minutes (HHMM)
5.
Set the connection according to the length of the codes to be read:
Code Length
≤
240 Characters
ÌRA1aÎ
Code Length >240 Characters
(not for systems with BC-8000 as Master)
ÌRA2dÎ