Wireless Features
Product Reference Guide
305
STAR Radio Protocol Timeout
This parameter sets the valid wait time before transmission between the
handheld reader and Base Station is considered failed.
When setting this parameter, take into consideration the radio traffic (num-
ber of readers in the same area). The selectable range for this feature is from
02 to 25 seconds.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield two digits. For example: 2
= 02, 5 = 05, 25 = 25, etc
3. Go to
and scanScan the ENTER/EXIT PROGRAMMING MODE
barcode to enter Programming Mode.
4. Scan the barcode: SELECT RADIO PROTOCOL TIMEOUT.
5. Scan the appropriate two digits from the keypad in
, that represent the duration which was determined in the steps
above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar-
code to abort and not save the entry string. You can then start again
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
ming Mode.
This completes the procedure. See
for some examples of how to
set this feature.
Table 44. STAR Radio Protocol Timeout Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
2 Seconds
5 Seconds
10 Seconds
25 Seconds
2
Pad with leading
zero(es)
02
05
10
25
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECTSTAR RADIO PROTOCOL TIMEOUT SETTING
5
Scan Two Characters
From
‘0’ and ‘2’
‘0’ and ‘5’
‘1’ and ‘0’
‘2’ AND ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
Содержание PowerScan 9501-AR Series
Страница 32: ...Setup 22 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 36: ...Configuration Using Bar Codes 26 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 92: ...Enter Exit Programming Mode 82 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 184: ...174 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 318: ...References 308 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 322: ...Message Formatting 312 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 360: ...Scancode Tables 350 PowerScan PD9531 AR PBT9501 AR PM9501 AR...