References
304
PowerScan™ PD9531-AR/PBT9501-AR/PM9501-AR
Wireless Features
Automatic Configuration Update
When this feature is enabled, the base station and reader will keep their
configurations synchronized. If a reader's configuration is altered by reading
programming labels, this change is automatically transferred and updated in
a linked base station. Likewise, if the base station's configuration is changed
using Aladdin or by host commands, then the reader's configuration will
automatically be updated if this feature is enabled.
RF Address Stamping
Source Radio Address Delimiter Character
This option specifies the delimiter character to be placed between the label
data and radio address when address stamping is enabled.
This feature only applies if
"Source Radio Address Transmis-
on page 219 is enabled.
Follow these instructions to select the delimiter character:
1. Determine the desired character, then find its hexadecimal equivalent
on the
on the inside back cover. A setting of 00 specifies no
delimiter character.
2. Go to
and scan the ENTER/EXIT PROGRAMMING MODE bar
code to enter Programming Mode.
3. Scan the bar code: SET SOURCE RADIO ADDRESS DELIMITER CHARAC-
TER.
4. Scan the appropriate two digits from the keypad in
, that represent the hexadecimal characters which were determined
in the steps above. You will hear a two-beep indication after the last
character.
If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again
at the beginning.
5. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
Table 43. Source Radio Address Delimiter Character Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
No delim-
iter
character
,
(comma
)
- (dash)
/ (slash)
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SET SOURCE RADIO ADDRESS DELIMiTER CHARACTER
4
Scan Two Characters From
‘0’ and ‘0’
‘2’ and
‘C’
‘2’ and ‘D’
‘2’ AND ‘F’
5
Scan ENTER/EXIT PROGRAMMING MODE
Содержание PowerScan 9501-AR Series
Страница 32: ...Setup 22 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 36: ...Configuration Using Bar Codes 26 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 92: ...Enter Exit Programming Mode 82 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 184: ...174 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 318: ...References 308 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 322: ...Message Formatting 312 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 360: ...Scancode Tables 350 PowerScan PD9531 AR PBT9501 AR PM9501 AR...