background image

UPC-A

Product Reference Guide

        

                   127

UPC-A — cont.

Expand UPC-A to EAN-13

Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the 
symbology ID to match those required for EAN-13.

UPC-A Number System Character Transmission

This feature enables/disables transmission of the UPC-A number system character.

ENTER/EXIT PROGRAMMING MODE

UPC-A to EAN-13 = Don’t Expand

UPC-A to EAN-13 = Expand

DEFAULT

ENTER/EXIT PROGRAMMING MODE

UPC-A Number System Character = Do not transmit

UPC-A Number System Character = Transmit

DEFAULT

Содержание PD7110-BB

Страница 1: ...pport POSMicro com Monday Friday 6 AM to 5 PM Pacific Time Bulk Discounts FREE SHIPPING SE Habla Espa ol Free ground shipping to the continental USA on orders over 100 For Help Call 1 800 241 6264 Dat...

Страница 2: ...PowerScanTM PD7100 Industrial Corded Handheld Linear Imager Bar Code Reader Product Reference Guide...

Страница 3: ...06 5015831 5019697 5019698 5086879 5115120 5144118 5146463 5179270 5198649 5200597 5202784 5208449 5210397 5212371 5212372 5214270 5229590 5231293 5232185 5233169 5235168 5237161 5237162 5239165 52471...

Страница 4: ...mission 9 Resetting the Product Configuration to Defaults 9 Chapter 3 Interfaces 11 Interface Selection 11 Configuring the Interface 11 Global Interface Features 15 Host Commands Obey Ignore 15 USB Su...

Страница 5: ...haracter 66 Enable Character 68 Chapter 7 Keyboard Interface 71 Introduction 71 Standard Factory Settings 71 Scancode Tables 71 Country Mode 72 Caps Lock State 75 Numlock 75 Send Control Characters 76...

Страница 6: ...ck Character Transmission 126 Expand UPC A to EAN 13 127 UPC A Number System Character Transmission 127 In Store Minimum Reads 128 UPC E 129 UPC E Enable Disable 129 UPC E Check Character Transmission...

Страница 7: ...n 170 Code 39 Start Stop Character Transmission 170 Code 39 Full ASCII 171 Code 39 Quiet Zones 172 Code 39 Minimum Reads 173 Code 39 Decoding Level 174 Code 39 Length Control 176 Code 39 Set Length 1...

Страница 8: ...aracter Transmission 229 Codabar Start Stop Character Transmission 229 Codabar Start Stop Character Set 230 Codabar Start Stop Character Match 231 Codabar Quiet Zones 232 Codabar Minimum Reads 233 Cod...

Страница 9: ...128 Force Concatenation 286 ISBT 128 Advanced Concatenation Options 286 MSI 287 MSI Enable Disable 287 MSI Check Character Calculation 288 MSI Check Character Transmission 289 MSI Length Control 289...

Страница 10: ...Follett 2 of 5 333 Follett 2 of 5 Enable Disable 333 Appendix A Technical Specifications 335 Standard Cable Pinouts 337 Appendix B Standard Defaults 339 Default Exceptions 350 Appendix C LED and Beepe...

Страница 11: ...8 PowerScanTM PD7100 Corded...

Страница 12: ...using a serial or USB cable and can also create configuration barcodes to print Manual Overview Chapter 1 Introduction provides a product overview unpacking instructions and cable connection informati...

Страница 13: ...e scanned for certain parameter set tings Appendix F Scancode Tables lists control character emulation information for Wedge and USB Keyboard interfaces Manual Conventions The following conventions ar...

Страница 14: ...are updates demos and instructions for returning products for repair Reseller Technical Support An excellent source for technical assistance and information is an authorized Datalogic reseller A resel...

Страница 15: ...Introduction 4 PowerScanTM PD7100 Corded NOTES...

Страница 16: ...design of the reader will help to promote comfortable han dling during extended periods of use See Interface Selection on page 11 for a listing and descriptions of available interface sets by model ty...

Страница 17: ...p the retainer over the cable connector as shown in the illustra tion then fully seat the cable assembly into the reader aligning both the connector and the retainer boss with their respective opening...

Страница 18: ...n Connection Connect the reader to the Wand Emulation port on the terminal PC using the correct cable Reference Figure 2 Figure 2 Other Interface Connections Programming The reader is factory configur...

Страница 19: ...code in that section to select your system s correct interface type Configure Interface Settings If after scanning the interface barcode from the Interfaces section your installation requires you to s...

Страница 20: ...to restore the Factory Configuration you have two options You can scan the Restore USA Factory Configuration bar code or the Restore EU Factory Configuration bar code below Both labels restore the ima...

Страница 21: ...Getting Started 10 PowerScanTM PD7100 Corded NOTES...

Страница 22: ...ll be connected to Next proceed to the corre sponding chapter in this manual also listed in Table 1 to configure any desired settings and features associated with that interface NOTE Unlike some other...

Страница 23: ...UPOS JavaPOS Select RS 232 OPOS Select USB COM STDa USB Com to simulate RS 232 standard interface IBM FEATURES Select IBM P5B IBM 46xx Port 5B reader interface Set IBM Interface Features starting on p...

Страница 24: ...n page 71 Select KBD AT NK Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Alternate Key Select KBD AT ALT Select K...

Страница 25: ...eyboard Wedge for IBM Terminals 31xx 32xx 34xx 37xx make break keyboard Keyboard Wedge for DIGITAL Terminals VT2xx VT3xx VT4xx Select KBD DIG VT Select USB Keyboard USB Keyboard with standard key enco...

Страница 26: ...n page 45 Keyboard Interface on page 71 USB OEM Interface on page 85 IBM 46XX Interface on page 89 Host Commands Obey Ignore This option specifies whether the reader will obey or ignore host commands...

Страница 27: ...6 PowerScanTM PD7100 Corded USB Suspend Mode This setting enables disables the ability of USB interfaces to enter suspend mode ENTER EXIT PROGRAMMING MODE USB Suspend Mode Disable USB Suspend Mode Ena...

Страница 28: ...logy and data If the unit reads a label and sees the same label again within the Double Read Timeout the second read of the label will be ignored Double Read Timeout does not apply to scan modes that...

Страница 29: ...d Double Read Timeout continued ENTER EXIT PROGRAMMING MODE Double Read Timeout 0 5 Second Double Read Timeout 0 6 Second Double Read Timeout 0 7 Second Double Read Timeout 0 8 Second Double Read Time...

Страница 30: ...CT LABEL GONE TIMEOUT SETTING 5 Scan the appropriate three alpha numeric characters from the keypad in Appendix E Keypad representing the duration which was determined in the steps above You will hear...

Страница 31: ...d Label Gone Timeout cont ENTER EXIT PROGRAMMING MODE Select Label Gone Timeout Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the be...

Страница 32: ...fies the timeout value for the reader to enter low power Sleep Mode ENTER EXIT PROGRAMMING MODE Sleep Mode Timeout Disable Sleep Mode Timeout 500ms Sleep Mode Timeout 1 Second Sleep Mode Timeout 2 Sec...

Страница 33: ...Sleep Mode Timeout continued ENTER EXIT PROGRAMMING MODE Sleep Mode Timeout 5 Seconds Sleep Mode Timeout 6 Seconds Sleep Mode Timeout 7 Seconds Sleep Mode Timeout 8 Seconds Sleep Mode Timeout 9 Secon...

Страница 34: ...Guide 23 LED and Beeper Indicators Power On Alert Disables or enables the indication from the Beeper that the reader is receiving power ENTER EXIT PROGRAMMING MODE Power On Alert Disable No Audible I...

Страница 35: ...ully reading a barcode Choices are Good Read Indicate after decode Good Read Indicate after transmit Good Read Indicate after CTS goes inactive then active NOTE This option which uses CTS is only vali...

Страница 36: ...ndicators Product Reference Guide 25 Good Read Beep Type Specifies whether the good read beep has a mono or bitonal beep sound ENTER EXIT PROGRAMMING MODE Good Read Beep Type Mono Good Read Beep Type...

Страница 37: ...or high frequency se lectable from the list below Controls the beeper s pitch tone Good Read Beep Length Specifies the duration of a good read beep ENTER EXIT PROGRAMMING MODE Good Read Beep Frequenc...

Страница 38: ...Length continued ENTER EXIT PROGRAMMING MODE Good Read Beep Length 80 msec Good Read Beep Length 100 msec Good Read Beep Length 120 msec Good Read Beep Length 140 msec Good Read Beep Length 160 msec G...

Страница 39: ...ep Volume Selects the beeper volume loudness upon a good read beep There are three selectable volume levels ENTER EXIT PROGRAMMING MODE Good Read Beep Volume Beeper Off Good Read Beep Volume Low Good...

Страница 40: ...D DURATION SETTING 5 Scan the appropriate three digits from the keypad in Appendix E Keypad represent ing the duration which was determined in the steps above You will hear a two beep indication after...

Страница 41: ...R EXIT PROGRAMMING MODE Select Good Read LED Duration Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the beginning CANCEL DEFAULT 020...

Страница 42: ...ntil Scanning Active Time has elapsed or the trigger has been released and pulled again Double Read Timeout1 prevents undesired multiple reads of the same label while in this mode Flashing The reader...

Страница 43: ...rded Scan Mode continued ENTER EXIT PROGRAMMING MODE Scan Mode Trigger Single Scan Mode Trigger Hold Multiple Scan Mode Trigger Pulse Multiple Scan Mode Flashing Scan Mode Always On Scan Mode Stand Mo...

Страница 44: ...rigger is pulled while in Stand Mode NOTE This timeout is only used when the Scan Mode is configured as Stand Mode ENTER EXIT PROGRAMMING MODE Stand Mode Triggered Timeout 0 5 Seconds Stand Mode Trigg...

Страница 45: ...D7100 Corded Stand Mode Triggered Timeout continued ENTER EXIT PROGRAMMING MODE Stand Mode Triggered Timeout 6 Seconds Stand Mode Triggered Timeout 8 Seconds Stand Mode Triggered Timeout Switch back t...

Страница 46: ...t rep resent the duration which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Program ming Mode...

Страница 47: ...Active Time cont ENTER EXIT PROGRAMMING MODE Select Scanning Active Time Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the beginnin...

Страница 48: ...n Appendix E Keypad represent ing the duration which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to ex...

Страница 49: ...ded Flash On Time cont ENTER EXIT PROGRAMMING MODE Select Flash ON Time Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the beginning...

Страница 50: ...in Appendix E Keypad that repre sent the duration which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to...

Страница 51: ...ded Flash Off Time cont ENTER EXIT PROGRAMMING MODE Select Flash OFF Time Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the beginnin...

Страница 52: ...nce Guide 41 Stand Mode Sensitivity Sets the sensitivity level for stand mode wakeup Choices are low medium and high ENTER EXIT PROGRAMMING MODE Stand Mode Sensitivity Low Stand Mode Sensitivity Mediu...

Страница 53: ...by this feature Immediately following this the reader will start scanning NOTE The Laser Pointer is a value added option which might not have been included when your reader was ordered ENTER EXIT PRO...

Страница 54: ...be activated for the time specified by Laser Pointer Control then start blinking OFF then ON at a 50 duty cycle and a repeating period set by Laser Pointer Period ENTER EXIT PROGRAMMING MODE Laser Poi...

Страница 55: ...ion Specifies the duration of the good read pointer beam after a good read ENTER EXIT PROGRAMMING MODE Green Spot Duration Disable Green Spot is Off Green Spot Duration Short 300 msec Green Spot Durat...

Страница 56: ...USB interfaces are available in Chapter 6 RS 232 USB Com Interfaces RS 232 Standard Factory Settings Reference Appendix B Standard Defaults for a listing of standard factory settings Baud Rate Baud ra...

Страница 57: ...RS 232 ONLY Interface 46 PowerScanTM PD7100 Corded Baud Rate continued ENTER EXIT PROGRAMMING MODE Baud Rate 9600 Baud Rate 19 200 Baud Rate 38 400 Baud Rate 57 600 Baud Rate 115 200 DEFAULT...

Страница 58: ...eference Guide 47 Data Bits This parameter allows the reader to interface with devices requiring a 7 bit or 8 bit ASCII protocol for sending and receiving data ENTER EXIT PROGRAMMING MODE 7 Data Bits...

Страница 59: ...ion of one character and prepares the receiving device for the next character in the serial data stream The number of stop bits selected one or two depends on the number the receiving terminal is prog...

Страница 60: ...ice requirements Select None when no parity bit is required Select Odd parity and the parity bit value is set to 0 or 1 based on data to ensure that an odd number of 1 bits are contained in the coded...

Страница 61: ...CTS RTS is asserted during transmissions CTS gates transmissions RTS XON XOFF RTS is asserted during transmissions CTS is ignored XON and XOFF gate transmissions RTS On CTS RTS is always asserted CTS...

Страница 62: ...SB Com Interfaces Introduction The programming barcodes in this chapter allow modifications to the standard RS 232 and USB Com interfaces Standard Factory Settings Reference Appendix B Standard Defaul...

Страница 63: ...riate two digits from the keypad in Appendix E Keypad that rep resent the duration which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER...

Страница 64: ...lay cont ENTER EXIT PROGRAMMING MODE Intercharacter Delay No Delay Select Intercharacter Delay Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start...

Страница 65: ...to gain a user s attention to an illegal entry or other important event Beep On Not on File This option enables disables the action of the reader to sound a three beep sequence upon receiving a Not O...

Страница 66: ...label transmission The reader expects an ACK NAK response from the host when a label is sent Enable for host command acknowledge The reader will respond with ACK NAK when the host sends a command Enab...

Страница 67: ...E Keypad that represent the desired character value in step 1 above The second character will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Program ming Mode This...

Страница 68: ...ACK NAK Options Product Reference Guide 57 ACK Character cont ENTER EXIT PROGRAMMING MODE Select ACK Character Setting DEFAULT 0x06 ACK Character...

Страница 69: ...E Keypad that represent the desired character value in step 1 above The second character will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Program ming Mode This...

Страница 70: ...ACK NAK Options Product Reference Guide 59 NAK Character cont ENTER EXIT PROGRAMMING MODE Select NAK Character Setting DEFAULT 0x15 NAK Character...

Страница 71: ...NG 5 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the duration which was determined in the steps above You will hear a two beep indication after the last charac...

Страница 72: ...imeout Value cont ENTER EXIT PROGRAMMING MODE Select ACK NAK Timeout Value Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the beginni...

Страница 73: ...pendix E Keypad that represent the number which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Pr...

Страница 74: ...63 ACK NAK Retry Count cont ENTER EXIT PROGRAMMING MODE Select ACK NAK Retry Count Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the...

Страница 75: ...while waiting for an ACK character from the host Options are Ignore errors detected Process error as valid ACK character Process error as valid NAK character ENTER EXIT PROGRAMMING MODE ACK NAK Error...

Страница 76: ...ion Failure This option enables disables the reader s ability to sound an error beep to indicate a transmission failure while in ACK NAK mode ENTER EXIT PROGRAMMING MODE Indicate Transmission Failure...

Страница 77: ...ypad in Appendix E Keypad that represent the desired character value in step 1 above The second character will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Progra...

Страница 78: ...Disable Character Product Reference Guide 67 Disable Character cont ENTER EXIT PROGRAMMING MODE Select Disable Character Setting DEFAULT 0x44 Disable Character is D...

Страница 79: ...haracters from the keypad in Appendix E Keypad that represent the desired character value in step 2 above The second character will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE b...

Страница 80: ...Enable Character Product Reference Guide 69 Enable Character cont ENTER EXIT PROGRAMMING MODE Select Enable Character Setting DEFAULT 0x45 Enable Character is E...

Страница 81: ...RS 232 USB Com Interfaces 70 PowerScanTM PD7100 Corded NOTES...

Страница 82: ...apter to select options for USB Keyboard and Wedge Interfaces Standard Factory Settings Reference Appendix B Standard Defaults for a listing of standard factory settings Scancode Tables Information ab...

Страница 83: ...yboard AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 without Alternate Key Keyboard Wedge for IBM AT PS2 without alternate key encoding but without external keyboard All other interfaces support ONLY th...

Страница 84: ...ure description Country Mode France Country Mode Germany Supports only the interfaces listed in theCountry Mode feature description Country Mode Hungary Country Mode Italy Supports only the interfaces...

Страница 85: ...interfaces listed in theCountry Mode feature description Country Mode Portugal Country Mode Romania Supports only the interfaces listed in theCountry Mode feature description Supports only the interf...

Страница 86: ...is selected Numlock This option specifies the setting of the Numbers Lock Numlock key while in keyboard wedge interface This only applies to alternate key encoding interfaces It does not apply to USB...

Страница 87: ...Ctrl Keys special keys are located from 0x80 to 0xA1 Control Character 01 Characters from 00 to 0x1F are sent as control character Ctrl Capital Key special keys are located from 0x80 to 0xA1 Control...

Страница 88: ......

Страница 89: ...dge Quiet Interval cont ENTER EXIT PROGRAMMING MODE Select Wedge Quiet Interval Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the be...

Страница 90: ...Appendix E Keypad that rep resent the duration which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to ex...

Страница 91: ...lay cont ENTER EXIT PROGRAMMING MODE Intercharacter Delay No Delay Select Intercharacter Delay Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start...

Страница 92: ...the duration which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Program ming Mode This complet...

Страница 93: ...Corded Intercode Delay cont ENTER EXIT PROGRAMMING MODE Set Intercode Delay Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the beginning CAN...

Страница 94: ...s option specifies the USB poll rate for a USB keyboard NOTE This feature applies ONLY to the USB Keyboard interface ENTER EXIT PROGRAMMING MODE USB Keyboard Speed 1ms USB Keyboard Speed 2ms USB Keybo...

Страница 95: ...nterface 84 PowerScanTM PD7100 Corded USB Keyboard Speed continued ENTER EXIT PROGRAMMING MODE USB Keyboard Speed 6ms USB Keyboard Speed 7ms USB Keyboard Speed 8ms USB Keyboard Speed 9ms USB Keyboard...

Страница 96: ...reader will be connected with Use the feature settings in this chapter and Chapter 9 IBM 46XX Interface to specifically configure for the USB OEM interface Other USB interfaces are included in the ap...

Страница 97: ...nners you may already have con nected to a USB OEM POS you may need to change this setting to enable all devices to communicate Options are Table Top Scanner Handheld Scanner NOTE It may be necessary...

Страница 98: ...ns This setting provides for an interface specific control mechanism Options are Obey Obey Scanner Configuration Host Commands Ignore Ignore Scanner Configuration Host Commands ENTER EXIT PROGRAMMING...

Страница 99: ...USB OEM Interface 88 PowerScanTM PD7100 Corded NOTES...

Страница 100: ...46XX Interface Introduction Use the barcodes in this section to configure programmable features for available IBM 46XX interfaces IBM Standard Factory Settings Reference Appendix B Standard Defaults f...

Страница 101: ...ive second period to allow the user to enter Programming Mode and configure the reader The con figurable range for this feature is 1 to 15 resets ENTER EXIT PROGRAMMING MODE 46xx Number of Host Resets...

Страница 102: ...Guide 91 46xx Number of Host Resets cont ENTER EXIT PROGRAMMING MODE 46xx Number of Host Resets 7 46xx Number of Host Resets 8 46xx Number of Host Resets 9 46xx Number of Host Resets 10 46xx Number of...

Страница 103: ...IBM 46XX Interface 92 PowerScanTM PD7100 Corded 46xx Number of Host Resets cont ENTER EXIT PROGRAMMING MODE 46xx Number of Host Resets 13 46xx Number of Host Resets 14 46xx Number of Host Resets 15...

Страница 104: ...translation The data is not converted to Code 39 or verified to be valid for Code 39 Options are IBM Standard Format Send labels in standard IBM format Code 39 Format Translate the following symbologi...

Страница 105: ...This setting provides for an interface specific control mechanism Options are Obey Obey Scanner Configuration Host Commands Ignore Ignore Scanner Configuration Host Commands ENTER EXIT PROGRAMMING MO...

Страница 106: ...erface Wand Emulation Standard Factory Settings Reference Appendix B Standard Defaults for a listing of standard factory settings Wand Idle State This feature specifies the level of the Wand output si...

Страница 107: ...the Wand output signal Choices are Quiet zones and spaces are high bars are low Quiet zones and spaces are low bars are high NOTE TTL logic levels 0V Low 0 7V 2 4V High 5 25V ENTER EXIT PROGRAMMING M...

Страница 108: ...ide 97 Wand Signal Speed This feature specifies the speed of the Wand output signal per nominal bar or space Choices are 330 microseconds 660 microseconds ENTER EXIT PROGRAMMING MODE Wand Signal Speed...

Страница 109: ...erted to a single symbology Options are No conversion Convert to Code 39 symbology Convert to Code 39 Full ASCII Convert to Code 128 symbology ENTER EXIT PROGRAMMING MODE Label Symbology Conversion No...

Страница 110: ...interface Choices are Disable no leading trailing noise Enable leading noise Enable trailing noise Enable leading and trailing noise ENTER EXIT PROGRAMMING MODE Transmit Noise Disable Transmit Noise T...

Страница 111: ...Wand Emulation Interface 100 PowerScanTM PD7100 Corded NOTES...

Страница 112: ...cific symbologies Figure 3 shows the available elements you can add to a message string Figure 3 Breakdown of a Message String CAUTION It is not recommended to use these features with IBM interfaces N...

Страница 113: ...position before the barcode data and or as a suffix in a position following the barcode data as indicated in Figure 4 Figure 4 Prefix and Suffix Positions Example Setting a Prefix In this example we...

Страница 114: ...place the unit in Programming Mode then the Set Global Prefix or Set Global Suffix barcode followed by the digits in hex from the Alphanumeric characters in Appendix E Key pad representing your desire...

Страница 115: ...ollowed by A modifier character the modifier character is symbol dependent Figure 5 AIM ID NOTE This feature enables disables addition of AIM IDs for all symbology types SYMBOLOGY CHAR SYMBOLOGY CHAR...

Страница 116: ...Global AIM ID Product Reference Guide 105 Global AIM ID continued ENTER EXIT PROGRAMMING MODE Global AIM ID Disable Global AIM ID Enable DEFAULT...

Страница 117: ...M ID for GS1 128 can be enabled disabled inde pendently The AIM ID for GS1 128 is a C1 C2 or C3 AIM IDs for other symbologies can be enabled disabled independently as well Contact Customer Support for...

Страница 118: ...l ID Set Individually Per Symbology on page 110 If you wish to program the reader to always include an industry standard label identifier for ALL symbology types see the pre vious feature Global AIM I...

Страница 119: ...540000 CODE32 A 410000 X 580000 CODE39 2A0000 V 560000 CODE4 4 340000 4 340000 CODE5 j 6A0000 j 6A0000 CODE93 260000 U 550000 DATALOGIC 2OF5 s 730000 s 730000 EAN13 F 460000 B 420000 EAN13 P2 F 460000...

Страница 120: ...50000 e 650000 ISBN I 490000 400000 ISBT128 f 660000 f 660000 ISSN n 6E0000 n 6E0000 MSI 400000 Z 5A0000 Plessey a 610000 a 610000 S25 s 730000 P 500000 UPCA A 410000 C 430000 UPCA P2 A 410000 F 46000...

Страница 121: ...y 5 Turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID For example if you wish to select an equal sign as a Labe...

Страница 122: ...ction starting on page 113 GS1 DataBar Omnidirectional Code 39 Interleaved 2 of 5 Code 32 4 Custom Label ID example desired characters D B C 3 P H 5 Find hex equivalents from the ASCII table inside ba...

Страница 123: ...d or sent as a prefix or suffix for a given symbology type ENTER EXIT PROGRAMMING MODE Label ID Transmission Disable Label ID Transmission Enable as Prefix Label ID Transmission Enable as Suffix CANCE...

Страница 124: ...for which a Label ID is to be configured See Label ID on page 107 for full instructions ENTER EXIT PROGRAMMING MODE Set UPC A Label ID Character s Set UPC A P2 Label ID Character s Set UPC A P5 Label...

Страница 125: ...y for which a Label ID is to be configured See Label ID on page 107 for full instructions ENTER EXIT PROGRAMMING MODE Set UPC E P5 Label ID Character s Set UPC E GS1 128 Label ID Character s Set EAN 1...

Страница 126: ...ology for which a Label ID is to be configured See Label ID on page 107 for full instructions ENTER EXIT PROGRAMMING MODE Set EAN 8 Label ID Character s Set EAN 8 P2 Label ID Character s Set EAN 8 P5...

Страница 127: ...bel ID is to be configured See Label ID on page 107 for full instructions ENTER EXIT PROGRAMMING MODE Set GTIN P5 Label ID Character s Set GTIN GS1 128 Label ID Character s Set GS1 DataBar Omnidirecti...

Страница 128: ...configured See Label ID on page 107 for full instructions ENTER EXIT PROGRAMMING MODE Set Code 32 Label ID Character s Set Code 39 CIP Label ID Character s Set Code 128 Label ID Character s Set GS1 12...

Страница 129: ...for which a Label ID is to be configured See Label ID on page 107 for full instructions ENTER EXIT PROGRAMMING MODE Set Codabar Label ID Character s Set ABC Codabar Label ID Character s Set Code 11 L...

Страница 130: ...for which a Label ID is to be configured See Label ID on page 107 for full instructions ENTER EXIT PROGRAMMING MODE Set IATA Label ID Character s Set Concatinated ISBT 128 Label ID Character s Set MS...

Страница 131: ...nued This option selects the symbology for which a Label ID is to be configured See Label ID on page 107 for full instructions ENTER EXIT PROGRAMMING MODE Set Codablock F Label ID Character s Set Code...

Страница 132: ...ir is FF then no conversion is done For example if you have the character conversion configuration item set to the following 41423132FFFFFFFF The first pair is 4142 or AB 41 hex is an ASCII capital A...

Страница 133: ...the above example Next turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits needed to fulfill the string 4 Turn to Appendix E Keypad and scan the barcode...

Страница 134: ...widely used set of standard fac tory settings That section also provides space to record any custom settings needed or implemented for your system UPC A Datalogic 2 of 5 UPC E Codabar GTIN Formatting...

Страница 135: ...Symbologies 124 PowerScanTM PD7100 Corded Disable All Symbologies Scan this label to disable all symbologies ENTER EXIT PROGRAMMING MODE Disable all symbologies...

Страница 136: ...ables only GS1 DataBar coupon decoding To set this feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused barcodes on this and the facing...

Страница 137: ...reader will not read UPC A barcodes UPC A Check Character Transmission Enable this option to transmit the check character along with UPC A barcode data ENTER EXIT PROGRAMMING MODE UPC A Disable UPC A...

Страница 138: ...to match those required for EAN 13 UPC A Number System Character Transmission This feature enables disables transmission of the UPC A number system character ENTER EXIT PROGRAMMING MODE UPC A to EAN 1...

Страница 139: ...fore it is accepted as good read In store labels are defined as UPC A labels with a number system character of 2 or 4 as well as EAN 8 and EAN 13 labels with a Flag1 character of 2 or an EAN 13 label...

Страница 140: ...der will not read UPC E barcodes UPC E Check Character Transmission Enable this option to transmit the check character along with UPC E barcode data ENTER EXIT PROGRAMMING MODE UPC E Disable UPC E Ena...

Страница 141: ...ecting this feature also changes the symbology ID to match those required for EAN 13 Expand UPC E to UPC A Expands UPC E data to the UPC A data format ENTER EXIT PROGRAMMING MODE UPC E to EAN 13 Don t...

Страница 142: ...UPC E Number System Character Transmission This feature enables disables transmission of the UPC E system number character ENTER EXIT PROGRAMMING MODE UPC E Number System Character Do not transmit UP...

Страница 143: ...imum Reads This feature specifies the minimum number of consecutive times a UPC E label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE UPC E Minimum Reads 1 UPC E Minim...

Страница 144: ...PC E UPC A EAN 8 and EAN 13 labels into the GTIN 14 character format NOTE If add on information is present on the base label prior to the conver sion taking place the addon information will be appende...

Страница 145: ...eader will not read EAN 13 JAN 13 barcodes EAN 13 Check Character Transmission Enable this option to transmit the check character along with EAN 13 barcode data ENTER EXIT PROGRAMMING MODE EAN 13 Disa...

Страница 146: ...nt EAN 13 Flag 1 Character Enables disables transmission of an EAN JAN13 Flag1 character The Flag 1 character is the first character of the label ENTER EXIT PROGRAMMING MODE EAN 13 Flag 1 Char Don t t...

Страница 147: ...okland labels starting with 978 to ISBN labels ISSN Enable Disable Enables disables conversion of EAN JAN13 Bookland labels starting with 977 to ISSN labels ENTER EXIT PROGRAMMING MODE EAN 13 ISBN Con...

Страница 148: ...eads This feature specifies the minimum number of consecutive times an EAN 13 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE EAN 13 Minimum Reads 1 EAN 13 Minimum...

Страница 149: ...reader will not read EAN 8 JAN 8 barcodes EAN 8 Check Character Transmission Enable this option to transmit the check character along with EAN 8 barcode data ENTER EXIT PROGRAMMING MODE EAN 8 Disable...

Страница 150: ...eference Guide 139 EAN 8 cont Expand EAN 8 to EAN 13 Enable this option to expand EAN 8 JAN 8 labels to EAN 13 JAN 13 ENTER EXIT PROGRAMMING MODE Expand EAN 8 to EAN 13 Disable Expand EAN 8 to EAN 13...

Страница 151: ...Reads This feature specifies the minimum number of consecutive times an EAN 8 Jan 8 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE EAN 8 Minimum Reads 1 EAN 8 Mi...

Страница 152: ...oder This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors Choosing Level 3 which is the default setting allows t...

Страница 153: ...7100 Corded UPC EAN Global Settings cont UPC EAN Decoding Level cont ENTER EXIT PROGRAMMING MODE UPC EAN Decoding Level 1 UPC EAN Decoding Level 2 UPC EAN Decoding Level 3 UPC EAN Decoding Level 4 UPC...

Страница 154: ...that have some spots and or voids It may also help read labels that have damaged areas Enabling correlation will also increase the chances that a label will be read incorrectly UPC EAN Reconstruction...

Страница 155: ...lculation Enable 5 digit price weight check digit calculation Enable European 4 digit price weight check digit calculation Enable European 5 digit price weight check digit calculation ENTER EXIT PROGR...

Страница 156: ...cont UPC A Minimum Reads This feature specifies the minimum number of consecutive times a UPC A label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE UPC A Minimum Reads...

Страница 157: ...nal and conditional add ons NOTE If a UPC EAN base label and a an add on are both decoded the reader will transmit the base label and add on If a UPC EAN base label is decoded without an add on the ba...

Страница 158: ...Add Ons Product Reference Guide 147 Add Ons cont Optional Add ons cont ENTER EXIT PROGRAMMING MODE Optional Add Ons Enable P5 Optional Add Ons Disable GS1 128 Optional Add Ons Enable GS1 128 DEFAULT...

Страница 159: ...er will look for an add on when an add on fragment has been seen and optional add ons are enabled Also see Optional GS1 128 Add On Timer on page 151 ENTER EXIT PROGRAMMING MODE Optional Add on Timer 1...

Страница 160: ...Ons cont Optional Add On Timer cont ENTER EXIT PROGRAMMING MODE Optional Add on Timer 60ms Optional Add on Timer 70ms Optional Add on Timer 100ms Optional Add on Timer 120ms Optional Add on Timer 140...

Страница 161: ...t Optional Add On Timer cont ENTER EXIT PROGRAMMING MODE Optional Add on Timer 180ms Optional Add on Timer 200ms Optional Add on Timer 220ms Optional Add on Timer 240ms Optional Add on Timer 260ms Opt...

Страница 162: ...the linear EAN UPC part For UPC EAN add ons other than those of that type see Optional Add On Timer on page 148 ENTER EXIT PROGRAMMING MODE Optional GS1 128 Add On Timer Disable Optional GS1 128 Add O...

Страница 163: ...1 128 Add On Timer cont ENTER EXIT PROGRAMMING MODE Optional GS1 128 Add On Timer 60ms Optional GS1 128 Add On Timer 70ms Optional GS1 128 Add On Timer 100ms Optional GS1 128 Add On Timer 120ms Option...

Страница 164: ...t ENTER EXIT PROGRAMMING MODE Optional GS1 128 Add On Timer 180ms Optional GS1 128 Add On Timer 200ms Optional GS1 128 Add On Timer 220ms Optional GS1 128 Add On Timer 240ms Optional GS1 128 Add On Ti...

Страница 165: ...is feature specifies the minimum number of times a P2 add on must be read before it is marked as valid and then combined with a base label ENTER EXIT PROGRAMMING MODE P2 Add Ons Minimum Reads 1 P2 Add...

Страница 166: ...feature specifies the minimum number of times a P5 add on must be read before it is marked as valid and then combined with a base label ENTER EXIT PROGRAMMING MODE P5 Add Ons Minimum Reads 1 P5 Add On...

Страница 167: ...specifies the minimum number of times an GS1 128 add on must be read before it is marked as valid and then combined with a base label ENTER EXIT PROGRAMMING MODE GS1 128 Add Ons Minimum Reads 1 GS1 12...

Страница 168: ...ll not read GS1 DataBar Omnidirectional barcodes GS1 DataBar Omnidirectional GS1 128 Emulation When enabled GS1 DataBar Omnidirectional barcodes will be translated to the GS1 128 label data format ENT...

Страница 169: ...the minimum number of consecutive times a GS1 DataBar Omni directional label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE GS1 DataBar Omnidirectional Minimum Reads 1...

Страница 170: ...the reader will not read GS1 DataBar Expanded barcodes GS1 DataBar Expanded GS1 128 Emulation When enabled GS1 DataBar Expanded barcodes will be translated to the GS1 128 label data format ENTER EXIT...

Страница 171: ...e specifies the minimum number of consecutive times a GS1 DataBar Ex panded label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE GS1 DataBar Expanded Minimum Reads 1 GS...

Страница 172: ...th decoding or fixed length decoding for the GS1 DataBar Expanded symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed length decoding two differen...

Страница 173: ...AR EXPANDED LENGTH 1 SET TING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps above You will hear a two beep...

Страница 174: ...GS1 DataBar Expanded Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select GS1 DataBar Expanded Set Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You c...

Страница 175: ...the barcode SELECT GS1 DATABAR EXPANDED LENGTH 2 SET TING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps a...

Страница 176: ...GS1 DataBar Expanded Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select GS1 DataBar Expanded Set Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You ca...

Страница 177: ...e reader will not read GS1 DataBar Limited barcodes GS1 DataBar Limited GS1 128 Emulation When enabled GS1 DataBar Limited barcodes will be translated to the GS1 128 label data format ENTER EXIT PROGR...

Страница 178: ...feature specifies the minimum number of consecutive times a GS1 DataBar Limited label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE GS1 DataBar Limited Minimum Reads 1...

Страница 179: ...nTM PD7100 Corded Code 39 The following options apply to the Code 39 symbology Code 39 Enable Disable When disabled the reader will not read Code 39 barcodes ENTER EXIT PROGRAMMING MODE Code 39 Disabl...

Страница 180: ...led any check character in the label is treated as a data char acter ENTER EXIT PROGRAMMING MODE Code 39 Check Character Calculation Don t Calculate Code 39 Check Character Calculation Calculate Std C...

Страница 181: ...t Stop Character Transmission Enable this option to enable disable transmission of Code 39 start and stop characters ENTER EXIT PROGRAMMING MODE Code 39 Check Character Transmission Don t Send Code 39...

Страница 182: ...Code 39 cont Code 39 Full ASCII In Code 39 decoding this enables disables the translation of Code 39 characters to Code 39 full ASCII characters ENTER EXIT PROGRAMMING MODE Code 39 Full ASCII Disable...

Страница 183: ...areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label ENTER EXIT PROGRAMMING MODE Code 39 Quiet Zones Quiet Zone on one side Code 39 Quiet Zon...

Страница 184: ...eads This feature specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE Code 39 Minimum Reads 1 Code 39 Minim...

Страница 185: ...d of decoding errors Choosing Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to change the decoding level for a par...

Страница 186: ...erence Guide 175 Code 39 cont Code 39 Decoding Level cont ENTER EXIT PROGRAMMING MODE Code 39 Decoding Level 1 Code 39 Decoding Level 2 Code 39 Decoding Level 3 Code 39 Decoding Level 4 Code 39 Decodi...

Страница 187: ...coding or fixed length decoding for the Code 39 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different leng...

Страница 188: ...1 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps above You will hear a two beep indication after t...

Страница 189: ...Code 39 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Code 39 Set Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the...

Страница 190: ...MODE barcode to enter Program ming Mode 3 Scan the barcode SELECT CODE 39 LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting whi...

Страница 191: ...nt Code 39 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Code 39Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the be...

Страница 192: ...specifies the ratio between an intercharacter space and module for Code 39 labels ENTER EXIT PROGRAMMING MODE Code 39 Interdigit Ratio Disable Code 39 Interdigit Ratio 1 Code 39 Interdigit Ratio 2 Co...

Страница 193: ...nTM PD7100 Corded Code 39 cont Code 39 Interdigit Ratio cont ENTER EXIT PROGRAMMING MODE Code 39 Interdigit Ratio 6 Code 39 Interdigit Ratio 7 Code 39 Interdigit Ratio 8 Code 39 Interdigit Ratio 9 Cod...

Страница 194: ...scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correlation will also increa...

Страница 195: ...els When parts of a Code 39 bar code are presented to the reader with this feature enabled the barcode parts will be as sembled by the reader s software and the data will be decoded if all barcode pro...

Страница 196: ...ill not read Code 32 barcodes Code 32 Feature Setting Exceptions ENTER EXIT PROGRAMMING MODE Code 32 Disable Code 32 Enable DEFAULT NOTE The following features are set for Code 32 by using these Code...

Страница 197: ...ata Code 32 Start Stop Character Transmission This option enables disable transmission of Code 32 start and stop characters ENTER EXIT PROGRAMMING MODE Code 32 Check Character Transmission Don t Send...

Страница 198: ...ble Disable Enables Disables ability of the reader to decode Code 39 CIP labels Code 128 The following options apply to the Code 128 symbology Code 128 Enable Disable When disabled the reader will not...

Страница 199: ...labels Code 128 Check Character Transmission Enable this option to transmit the check character along with Code 128 barcode data ENTER EXIT PROGRAMMING MODE Code 128 to Code 39 Don t Expand Code 128 t...

Страница 200: ...Change Transmission Enables disables the transmission of Sub Code exchange characters NOT transmitted by standard decoding ENTER EXIT PROGRAMMING MODE Code 128 Function Character Transmission Don t Se...

Страница 201: ...e blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label ENTER EXIT PROGRAMMING MODE Code 128 Quiet Zones No Quiet Zones Code 128 Quiet Zo...

Страница 202: ...ads This feature specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE Code 128 Minimum Reads 1 Code 128 Min...

Страница 203: ...nse of increasing the likelihood of decoding errors Choosing Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to chan...

Страница 204: ...nce Guide 193 Code 128 cont Code 128 Decoding Level cont ENTER EXIT PROGRAMMING MODE Code 128 Decoding Level 1 Code 128 Decoding Level 2 Code 128 Decoding Level 3 Code 128 Decoding Level 4 Code 128 De...

Страница 205: ...coding or fixed length decoding for the Code 128 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different len...

Страница 206: ...TH 1 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps above You will hear a two beep indication after...

Страница 207: ...Code 128 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Code 128 Set Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at t...

Страница 208: ...Mode 3 Scan the barcode SELECT CODE 128 LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps abo...

Страница 209: ...t Code 128 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Code 128 Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the...

Страница 210: ...scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correlation will also increa...

Страница 211: ...128 labels When parts of a Code 128 barcode are presented to the reader with this feature enabled the barcode parts will be assembled by the reader s software and the data will be decoded if all barc...

Страница 212: ...sables the ability of the reader to translate GS1 128 labels to the GS1 128 data format Options are Transmit GS1 128 labels in Code 128 data format Transmit GS1 128 labels in GS1 128 data format Do no...

Страница 213: ...rded Interleaved 2 of 5 I 2 of 5 The following options apply to the I 2 of 5 symbology I 2 of 5 Enable Disable When disabled the reader will not read I 2 of 5 barcodes ENTER EXIT PROGRAMMING MODE I 2...

Страница 214: ...optional I 2 of 5 check character ENTER EXIT PROGRAMMING MODE I 2 of 5 Check Character Calculation Disable I 2 of 5 Check Character Calculation Check Standard Modulo 10 I 2 of 5 Check Character Calcul...

Страница 215: ...Check Character Transmission Enable this option to transmit the check character along with I 2 of 5 barcode data ENTER EXIT PROGRAMMING MODE I 2 of 5 Check Character Calculation Check Italian Post EN...

Страница 216: ...2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an I 2 of 5 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE I 2 of 5 Minimum R...

Страница 217: ...oding errors Choosing Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to change the decoding level for a particular...

Страница 218: ...Reference Guide 207 Interleaved 2 of 5 I 2 of 5 cont 2 of 5 Decoding Level cont ENTER EXIT PROGRAMMING MODE 2 of 5 Decoding Level 1 2 of 5 Decoding Level 2 2 of 5 Decoding Level 3 2 of 5 Decoding Leve...

Страница 219: ...length decoding or fixed length decoding for the I 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two diff...

Страница 220: ...de SELECT I 2 of 5 LENGTH 1 SETTING 5 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps above You will hear a tw...

Страница 221: ...5 cont Datalogic 2 of 5 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select I 2 of 5 Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start...

Страница 222: ...Program ming Mode 4 Scan the barcode SELECT I 2 of 5 LENGTH 2 SETTING 5 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in...

Страница 223: ...2 of 5 cont I 2 of 5 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select I 2 of 5 Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start aga...

Страница 224: ...data from multiple scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correlati...

Страница 225: ...for I 2 of 5 labels When parts of a I 2 of 5 barcode are presented to the reader with this feature enabled the barcode parts will be assembled by the reader s software and the data will be decoded if...

Страница 226: ...of reader to decode Interleaved 2 of 5 CIP HR labels Datalogic 2 of 5 The following options apply to the Datalogic 2 of 5 symbology Datalogic 2 of 5 Enable Disable When disabled the reader will not re...

Страница 227: ...5 Check Character Calculation This option enables disables calculation and verification of an optional Datalogic 2 of 5 check character ENTER EXIT PROGRAMMING MODE Datalogic 2 of 5 Check Character Ca...

Страница 228: ...ive times an Datalogic 2 of 5 la bel must be decoded before it is accepted as good read Datalogic 2 of 5 Decoding Level ENTER EXIT PROGRAMMING MODE I 2 of 5 Minimum Reads 1 I 2 of 5 Minimum Reads 2 I...

Страница 229: ...ng or fixed length decoding for the Datalogic 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different...

Страница 230: ...I 2 of 5 LENGTH 1 SETTING 5 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps above You will hear a two beep ind...

Страница 231: ...atalogic 2 of 5 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Datalogic 2 of 5 Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start...

Страница 232: ...Mode 4 Scan the barcode SELECT Datalogic 2 of 5 LENGTH 2 SETTING 5 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the s...

Страница 233: ...talogic 2 of 5 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Datalogic 2 of 5 Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start a...

Страница 234: ...intercharacter space and module for Datalogic 2 of 5 ENTER EXIT PROGRAMMING MODE Datalogic 2 of 5 Interdigit Maximum Ratio Disable Datalogic 2 of 5 Interdigit Maximum Ratio 1 Datalogic 2 of 5 Interdig...

Страница 235: ...f 5 Interdigit Maximum Ratio cont Datalogic 2 of 5 Interdigit Maximum Ratio 6 Datalogic 2 of 5 Interdigit Maximum Ratio 7 Datalogic 2 of 5 Interdigit Maximum Ratio 8 Datalogic 2 of 5 Interdigit Maximu...

Страница 236: ...rom multiple scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correlation will...

Страница 237: ...f 5 labels When parts of a Data logic 2 of 5 barcode are presented to the reader with this feature enabled the barcode parts will be assembled by the reader s software and the data will be decoded if...

Страница 238: ...ence Guide 227 Codabar The following options apply to the Codabar symbology Codabar Enable Disable When disabled the reader will not read Codabar barcodes ENTER EXIT PROGRAMMING MODE Codabar Disable C...

Страница 239: ...erification of an optional Codabar check character When disabled any check character in the label is treated as a data character ENTER EXIT PROGRAMMING MODE Codabar Check Character Calculation Don t C...

Страница 240: ...top Character Transmission Enable this option to enable disable transmission of Codabar start and stop characters ENTER EXIT PROGRAMMING MODE Codabar Check Character Transmission Don t Send Codabar Ch...

Страница 241: ...racter Set This option specifies the format of transmitted Codabar start stop characters ENTER EXIT PROGRAMMING MODE Codabar Check Character Set ABCD TN E Codabar Check Character Set ABCD ABCD Codabar...

Страница 242: ...t Codabar Start Stop Character Match When enabled this option requires that start and stop characters match ENTER EXIT PROGRAMMING MODE Codabar Start Stop Character Match Don t Require Match Codabar S...

Страница 243: ...areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label ENTER EXIT PROGRAMMING MODE Codabar Quiet Zones Quiet Zone on one side Codabar Quiet Zon...

Страница 244: ...eads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE Codabar Minimum Reads 1 Codabar Minim...

Страница 245: ...se of increasing the likelihood of decoding errors Choosing Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to chang...

Страница 246: ...erence Guide 235 Codabar cont Codabar Decoding Level cont ENTER EXIT PROGRAMMING MODE Codabar Decoding Level 1 Codabar Decoding Level 2 Codabar Decoding Level 3 Codabar Decoding Level 4 Codabar Decodi...

Страница 247: ...coding or fixed length decoding for the Codabar symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different leng...

Страница 248: ...ELECT CODABAR LENGTH 1 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps above You will hear a two bee...

Страница 249: ...nt Codabar Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Codabar Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the b...

Страница 250: ...o enter Program ming Mode 3 Scan the barcode SELECT CODABAR LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determi...

Страница 251: ...nt Codabar Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select CodabarLength 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the be...

Страница 252: ...specifies the ratio between an intercharacter space and module for Codabar labels ENTER EXIT PROGRAMMING MODE Codabar Interdigit Ratio Disable Codabar Interdigit Ratio 1 Codabar Interdigit Ratio 2 Co...

Страница 253: ...nTM PD7100 Corded Codabar cont Codabar Interdigit Ratio cont ENTER EXIT PROGRAMMING MODE Codabar Interdigit Ratio 6 Codabar Interdigit Ratio 7 Codabar Interdigit Ratio 8 Codabar Interdigit Ratio 9 Cod...

Страница 254: ...scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correlation will also increa...

Страница 255: ...els When parts of a Codabar bar code are presented to the reader with this feature enabled the barcode parts will be as sembled by the reader s software and the data will be decoded if all barcode pro...

Страница 256: ...bles Disables ability of reader to decode ABC Codabar labels ABC Codabar Concatenation Mode Specifies the concatenation mode between Static and Dynamic ENTER EXIT PROGRAMMING MODE ABC Codabar Disable...

Страница 257: ...Dynamic Con catenation Mode ENTER EXIT PROGRAMMING MODE ABC Codabar Dynamic Concatenation Timeout 50 msec ABC Codabar Dynamic Concatenation Timeout 100 msec ABC Codabar Dynamic Concatenation Timeout...

Страница 258: ...uide 247 ABC Codabar cont ABC Codabar Force Concatenation Forces labels starting or ending with D to be concatenated ENTER EXIT PROGRAMMING MODE ABC Codabar Force Concatenation Disable ABC Codabar For...

Страница 259: ...nTM PD7100 Corded Code 11 The following options apply to the Code 11 symbology Code 11 Enable Disable When disabled the reader will not read Code 11 barcodes ENTER EXIT PROGRAMMING MODE Code 11 Disabl...

Страница 260: ...ables disables calculation and verification of optional Code 11 check char acter ENTER EXIT PROGRAMMING MODE Code 11 Check Character Calculation Disable Code 11 Check Character Calculation Check C Cod...

Страница 261: ...cont Code 11 Check Character Transmission This feature enables disables transmission of an optional Code 11 check character ENTER EXIT PROGRAMMING MODE Code 11 Check Character Transmission Don t Send...

Страница 262: ...eads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE Code 11 Minimum Reads 1 Code 11 Minim...

Страница 263: ...coding or fixed length decoding for the Code 11 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different leng...

Страница 264: ...G 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps above You will hear a two beep indication after the last c...

Страница 265: ...Code 11 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Code 11 Set Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the...

Страница 266: ...n the barcode SELECT CODE 11 LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps above You will...

Страница 267: ...nt Code 11 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Code 11 Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the b...

Страница 268: ...specifies the ratio between an intercharacter space and module for Code 11 labels ENTER EXIT PROGRAMMING MODE Code 11 Interdigit Ratio Disable Code 11 Interdigit Ratio 1 Code 11 Interdigit Ratio 2 Co...

Страница 269: ...nTM PD7100 Corded Code 11 cont Code 11 Interdigit Ratio cont ENTER EXIT PROGRAMMING MODE Code 11 Interdigit Ratio 6 Code 11 Interdigit Ratio 7 Code 11 Interdigit Ratio 8 Code 11 Interdigit Ratio 9 Cod...

Страница 270: ...reasing the likelihood of decoding errors Choosing Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to change the dec...

Страница 271: ...canTM PD7100 Corded Code 11 cont Code 11 Decoding Level cont ENTER EXIT PROGRAMMING MODE Codabar Decoding Level 1 Codabar Decoding Level 2 Codabar Decoding Level 3 Codabar Decoding Level 4 Codabar Dec...

Страница 272: ...scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correlation will also increa...

Страница 273: ...els When parts of a Code 11 bar code are presented to the reader with this feature enabled the barcode parts will be as sembled by the reader s software and the data will be decoded if all barcode pro...

Страница 274: ...ard 2 of 5 The following options apply to the Standard 2 of 5 symbology Standard 2 of 5 Enable Disable When disabled the reader will not read Standard 2 of 5 barcodes ENTER EXIT PROGRAMMING MODE Stand...

Страница 275: ...andard 2 of 5 Check Character Transmission This feature enables disables transmission of an optional Standard 2 of 5 check character ENTER EXIT PROGRAMMING MODE Standard 2 of 5 Check Character Calcula...

Страница 276: ...tandard 2 of 5 label must be decoded before it is accepted as good read Standard 2 of 5 Decoding Level ENTER EXIT PROGRAMMING MODE Standard 2 of 5 Minimum Reads 1 Standard 2 of 5 Minimum Reads 2 Stand...

Страница 277: ...ng or fixed length decoding for the Standard 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different...

Страница 278: ...RD 2 OF 5 LENGTH 1 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps above You will hear a two beep in...

Страница 279: ...tandard 2 of 5 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Standard 2 of 5 Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start ag...

Страница 280: ...Scan the barcode SELECT STANDARD 2 OF 5 LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that rep resent the length setting which was determined in the steps ab...

Страница 281: ...tandard 2 of 5 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Standard 2 of 5 Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start ag...

Страница 282: ...iple scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correlation will also in...

Страница 283: ...When parts of a Stan dard 2 of 5 barcode are presented to the reader with this feature enabled the barcode parts will be assembled by the reader s software and the data will be decoded if all bar code...

Страница 284: ...ode Industrial 2 of 5 labels Industrial 2 of 5 Check Character Calculation Enables Disables calculation and verification of an optional Industrial 2 of 5 check char acter ENTER EXIT PROGRAMMING MODE I...

Страница 285: ...t Industrial 2 of 5 Check Character Transmission Enables disables transmission of an Industrial 2 of 5 check character ENTER EXIT PROGRAMMING MODE Industrial 2 of 5 Check Character Transmission Disabl...

Страница 286: ...h decoding or fixed length decoding for the In dustrial 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two...

Страница 287: ...2 of 5 LENGTH 1 SETTING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which was determined in the steps above You will hear a two beep indi...

Страница 288: ...ndustrial 2 of 5 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Industrial 2 of 5 Set Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then...

Страница 289: ...ING MODE barcode to enter Programming Mode 3 Scan the barcode SELECT INDUSTRIAL 2 OF 5 LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the leng...

Страница 290: ...Industrial 2 of 5 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Industrial 2 of5 Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then star...

Страница 291: ...ture specifies the minimum number of consecutive times an Industrial 2 of 5 la bel must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE Industrial 2 of 5 Minimum Reads 1 Indu...

Страница 292: ...ial 2 of 5 Industrial 2 of 5 Character Correlation Enable disables character correlation for Industrial 2 of 5 ENTER EXIT PROGRAMMING MODE Industrial 2 of 5 Stitching Disable Industrial 2 of 5 Stitchi...

Страница 293: ...of the reader to decode IATA labels IATA Check Character Transmission Enables Disables calculation and verification of an optional Industrial 2 of 5 check char acter ENTER EXIT PROGRAMMING MODE IATA D...

Страница 294: ...8 The following options apply to the ISBT 128 symbology ISBT 128 Concatenation Use this option to enable disable ISBT128 concatenation of 2 labels ENTER EXIT PROGRAMMING MODE ISBN 128 Concatenation Di...

Страница 295: ...ncatenation Mode Specifies the concatenation mode between Static and Dynamic NOTE This option is only valid when ISBT 128 Concatenation is enabled see page 283 ENTER EXIT PROGRAMMING MODE ISBT 128 Con...

Страница 296: ...nation Mode ENTER EXIT PROGRAMMING MODE ISBT 128 Dynamic Concatenation Timeout 50 msec ISBT 128 Dynamic Concatenation Timeout 100 msec ISBT 128 Dynamic Concatenation Timeout 200 msec ISBT 128 Dynamic...

Страница 297: ...nced Concatenation Options NOTE This option is only valid when ISBT 128 Concatenation is enabled see page 283 ENTER EXIT PROGRAMMING MODE ISBT 128 Force Concatenation Disable ISBT 128 Force Concatenat...

Страница 298: ...ct Reference Guide 287 MSI The following options apply to the MSI symbology MSI Enable Disable Enables Disables ability of reader to decode MSI labels ENTER EXIT PROGRAMMING MODE MSI Disable MSI Enabl...

Страница 299: ...Disables calculation and verification of an optional MSI check character ENTER EXIT PROGRAMMING MODE MSI Check Character Calculation Disable MSI Check Character Calculation Enable Mod10 MSI Check Cha...

Страница 300: ...fixed length decoding for the MSI symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be se...

Страница 301: ...TING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which was determined in the steps above You will hear a two beep indi cation after the l...

Страница 302: ...SI Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select MSI Set Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the beginning...

Страница 303: ...ODE barcode to enter Programming Mode 3 Scan the barcode SELECT MSI LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which wa...

Страница 304: ...MSI Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select MSI Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the beginning CA...

Страница 305: ...inimum Reads This feature specifies the minimum number of consecutive times an MSI label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE MSI Minimum Reads 1 MSI Minimum...

Страница 306: ...ng Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to change the decoding level for a particular symbology These fac...

Страница 307: ...Symbologies 296 PowerScanTM PD7100 Corded MSI cont MSI Decoding Level cont MSI Decoding Level 3 MSI Decoding Level 4 MSI Decoding Level 5 DEFAULT...

Страница 308: ...ce Guide 297 Plessey The following options apply to the Plessey symbology Plessey Enable Disable Enables Disables ability of reader to decode Plessey labels ENTER EXIT PROGRAMMING MODE Plessey Disable...

Страница 309: ...nal Plessey check character ENTER EXIT PROGRAMMING MODE Plessey Check Character Calculation Disable Plessey Check Character Calculation Enable Plessey std check char verification Plessey Check Charact...

Страница 310: ...ixed length decoding for the Plessey symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be...

Страница 311: ...SETTING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which was determined in the steps above You will hear a two beep indi cation after t...

Страница 312: ...lessey Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Plessey Set Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the b...

Страница 313: ...ODE barcode to enter Programming Mode 3 Scan the barcode SELECT PLESSEY LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting whic...

Страница 314: ...Plessey Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Plessey Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the begi...

Страница 315: ...m Reads This feature specifies the minimum number of consecutive times a Plessey label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE Plessey Minimum Reads 1 Plessey Mi...

Страница 316: ...ng Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to change the decoding level for a particular symbology These fac...

Страница 317: ...y Decoding Level cont Plessey Stitching Enables disables fixed length stitching for Plessey Plessey Decoding Level 3 Plessey Decoding Level 4 Plessey Decoding Level 5 DEFAULT ENTER EXIT PROGRAMMING MO...

Страница 318: ...sey Code 93 The following options apply to the Code 93 symbology Code 93 Enable Disable Enables Disables ability of reader to decode Code 93 labels ENTER EXIT PROGRAMMING MODE Plessey Character Correl...

Страница 319: ...calculation and verification of an optional Code 93 check character ENTER EXIT PROGRAMMING MODE Code 93 Check Character Calculation Disable Code 93 Check Character Calculation Enable Check C Code 93...

Страница 320: ...g or fixed length decoding for the Code 93 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths m...

Страница 321: ...SETTING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which was determined in the steps above You will hear a two beep indi cation after t...

Страница 322: ...ode 93 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Code 93 Set Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the b...

Страница 323: ...ODE barcode to enter Programming Mode 3 Scan the barcode SELECT CODE 93 LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting whic...

Страница 324: ...Code 93 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Code 93 Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the begi...

Страница 325: ...m Reads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE Code 93 Minimum Reads 1 Code 93 Mi...

Страница 326: ...ng Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to change the decoding level for a particular symbology These fac...

Страница 327: ...Symbologies 316 PowerScanTM PD7100 Corded Code 93 cont Code 93 Decoding Level cont Code 93 Decoding Level 3 Code 93 Decoding Level 4 Code 93 Decoding Level 5 DEFAULT...

Страница 328: ...sables fixed length stitching for Code 93 ENTER EXIT PROGRAMMING MODE Code 93 Quiet Zones No Quiet Zones Code 93 Quiet Zones Quiet Zone on one side Code 93 Quiet Zones Quiet Zones on two sides Code 93...

Страница 329: ...ength stitching for Code 93 Code 93 Character Correlation Enables disables Character Correlation for Code 93 ENTER EXIT PROGRAMMING MODE Code 93 Stitching Disable Code 93 Stitching Enable DEFAULT ENTE...

Страница 330: ...odablock F The following options apply to the Codablock F symbology Codablock F Enable Disable Enables Disables the ability of the imager to decode Codablock F labels ENTER EXIT PROGRAMMING MODE Codab...

Страница 331: ...N subtype code with FNC1 in the first position Codablock F AIM Check Specifies if Check Digit calculation algorithm is AIM compliant or not ENTER EXIT PROGRAMMING MODE Codablock F EAN Disable Codabloc...

Страница 332: ...th decoding or fixed length decoding for the Codablock F symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two diffe...

Страница 333: ...SETTING 4 Scan the appropriate three digits from the keypad in the Keypad Appendix that represent the length setting which was determined in the steps above You will hear a two beep indi cation after...

Страница 334: ...Codablock F Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Codablock F Length 1 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at...

Страница 335: ...barcode to enter Programming Mode 3 Scan the barcode SELECT CODABLOCK F LENGTH 2 SETTING 4 Scan the appropriate three digits from the keypad in the Keypad Appendix that represent the length setting wh...

Страница 336: ...odablock F Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Codablock F Length 2 Setting Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at t...

Страница 337: ...anTM PD7100 Corded Code 4 The following options apply to the Code 4 symbology Code 4 Enable Disable Enables Disables ability of imager to decode Code 4 labels ENTER EXIT PROGRAMMING MODE Code 4 Disabl...

Страница 338: ...de 4 Hex to Decimal Conversion This feature enables disables the conversion of hexidecimal label data to decimal label da ta ENTER EXIT PROGRAMMING MODE Code 4 Check Character Transmission Don t Send...

Страница 339: ...anTM PD7100 Corded Code 5 The following options apply to the Code 5 symbology Code 5 Enable Disable Enables Disables ability of imager to decode Code 5 labels ENTER EXIT PROGRAMMING MODE Code 5 Disabl...

Страница 340: ...de 5 Hex to Decimal Conversion This feature enables disables the conversion of hexidecimal label data to decimal label da ta ENTER EXIT PROGRAMMING MODE Code 5 Check Character Transmission Don t Send...

Страница 341: ...ged labels at the expense of increasing the likelihood of decoding errors Choosing Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that...

Страница 342: ...Code 5 Common Configuration Items cont Code 4 and 5 Decoding Level cont ENTER EXIT PROGRAMMING MODE Code 4 and Code 5 Decoding Level 1 Code 4 and Code 5 Decoding Level 2 Code 4 and Code 5 Decoding Le...

Страница 343: ...um Reads This feature specifies the minimum number of consecutive times a Code 4 or Code 5 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE Code 4 or Code 5 Minimum...

Страница 344: ...tt 2 of 5 The following options apply to the Follett 2 of 5 symbology Follett 2 of 5 Enable Disable Enables Disables ability of imager to decode Follett 2 of 5 labels ENTER EXIT PROGRAMMING MODE Folle...

Страница 345: ...Symbologies 334 PowerScanTM PD7100 Corded NOTES...

Страница 346: ...Input current at 5V 285 mA max a 135 mA standby 2 5 mA RS 232 sleep mode 2 5 mA USB suspend Input Power 1 5W max in the 4 14V rangea Performance Characteristics Light Source Dual LEDs Roll Tilt Tolera...

Страница 347: ...ative humidity non condensing Drop Specifications 50 drops from 2 meters 6 5 feet to concrete 30 C to 50 C Ambient Light Immunity Up to 100 000 LUX in sunlight Contaminants Spray rain Dust particulate...

Страница 348: ...riptions in Table 46 apply to the connector on the reader and are for ref erence only Table 46 Standard Cable Pinouts Reader Side Pin 1 Pin 10 Cable Clip Latch To Host Cable Cable Strain Relief Bottom...

Страница 349: ...338 PowerScanTM PD7100 Corded NOTES...

Страница 350: ...referred default settings for these same configurable features Table 47 Standard Defaults Parameter Default Your Setting Page Number General Features Double Read Timeout 0 4 Second 17 Label Gone Timeo...

Страница 351: ...CII BEL Disable 54 Beep On Not on File Enable 54 ACK Character ACK 56 NAK Character NAK 58 ACK NAK Timeout Value 600 ms 60 ACK NAK Retry Count 3 Retries 62 ACK NAK Error Handling Ignore Errors Detecte...

Страница 352: ...al Speed 66 ms 97 Label Symbology Conversion No Conversion 98 Transmit Noise Disable 99 Data Editing Global Prefix Suffix No Global Prefix Global Suffix 0x0D CR 102 Global AIM ID Disable 104 GS1 128 A...

Страница 353: ...able Disable Enable 134 EAN 13 Check Character Transmission Send 134 EAN 13 Flag 1 Character Transmit 135 EAN 13 ISBN Conversion Disable 136 ISSN Enable Disable Disable 136 EAN 13 Minimum Reads 1 137...

Страница 354: ...xpanded Enable Disable Disable 159 GS1 DataBar Expanded GS1 128 Emula tion Disable 159 GS1 DataBar Expanded Minimum Reads 1 160 GS1 DataBar Expanded Length Control Variable 161 GS1 DataBar Expanded Se...

Страница 355: ...ptions 3 185 Code 32 Check Character Transmission Don t Send 186 Code 32 Start Stop Character Transmis sion Don t Transmit 186 Code 39 CIP French Pharmaceutical Code 39 CIP Enable Disable Disable 187...

Страница 356: ...ing Disable 214 Interleaved 2 of 5 CIP HR Interleaved 2 of 5 CIP HR Enable Disable Disable 215 Datalogic 2 of 5 Datalogic 2 of 5 Enable Disable Enable 215 Datalogic 2 of 5 Check Character Calcu lation...

Страница 357: ...racter Correlation Disable 243 Codabar Stitching Disable 244 ABC Codabar ABC Codabar Enable Disable Disable 245 ABC Codabar Concatenation Mode Static 245 ABC Codabar Dynamic Concatenation Timeout 200...

Страница 358: ...e 271 Standard 2 of 5 Stitching Disable 272 Industrial 2 of 5 Industrial 2 of 5 Enable Disable Disable 273 Industrial 2 of 5 Check Character Calcu lation Disable 273 Industrial 2 of 5 Check Character...

Страница 359: ...Set Length 2 50 Chars 292 MSI Minimum Reads 4 Reads 294 MSI Decoding Level Level 3 295 Disable 296 Plessey Plessey Enable Disable Disable 297 Plessey Check Character Calculation Enable Plessey Std and...

Страница 360: ...Enable Disable Disable 320 Codablock F AIM Check Enable Check C 320 Codablock F Length Control Variable 321 Codablock F Set Length 1 3 Chars 322 Codablock F Set Length 2 100 Chars 324 Code 4 Code 4 E...

Страница 361: ...erface RS232 WN Expand UPC A to EAN 13 Enable UPC E Check Character Transmission Disable Parity Odd Parity Handshaking Control RTS CTS Transmission Label ID Code Prefix GS1 128 AIM ID Disable UPCE Lab...

Страница 362: ...te 115200 Baud Transmission Label ID Code Prefix GS1 128 AIM ID Disable UPCA Label ID Character s C UPCE Label ID Character s D EAN 8 Label ID Character s A EAN 13 Label ID Character s B Code ISBN Lab...

Страница 363: ...L EAN13 P5 Label ID Character s M EAN13 GS1 128 Label ID Character s GS1 DataBar 14 Omnidirectional Label ID Character s u GS1 DataBar Expanded Label ID Character s t GS1 DataBar Limited Label ID Cha...

Страница 364: ...rors on the reader An optional Green Spot also performs useful functions The tables below list these indications One exception to the behaviors listed in the tables is that the reader s functions are...

Страница 365: ...continuously While in Stand Mode or Trigger Object Sense mode the green spot shall be on while in stand watch state N A N A Green Spota flashes momen tarily Upon successful read of a label the softwa...

Страница 366: ...olation mode If the reader is reset the sequence will be repeated The following table describes the LED flashes beep codes associated with an error found 1 Field Replaceable Unit FRU NUMBER OF LED FLA...

Страница 367: ...356 PowerScanTM PD7100 Corded NOTES...

Страница 368: ...rcodes in this appendix are typical representations for their symbology types UPC A EAN 13 Code 39 Code 128 Interleaved 2 of 5 0 12345 67890 5 3 456789 012340 123ABC 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7...

Страница 369: ...358 PowerScanTM PD7100 Corded Sample Barcodes continued Code 32 Codabar Code 93 Code 11...

Страница 370: ...low see GS1 DataBar RSS on page 359 10293847560192837465019283746029478450366523 GS1 DataBar Expanded Stacked 1234890hjio9900mnb GS1 DataBar Expanded 08672345650916 GS1 DataBar Limited 55432198673467...

Страница 371: ...360 PowerScanTM PD7100 Corded NOTES...

Страница 372: ...Product Reference Guide 361 Appendix E Keypad Use the barcodes in this appendix to enter numbers as you would select digits characters from a keypad 0 1 2 3 4 5...

Страница 373: ...362 PowerScanTM PD7100 Corded 6 7 8 9 A B C...

Страница 374: ...Product Reference Guide 363 D E F...

Страница 375: ...364 PowerScanTM PD7100 Corded NOTES...

Страница 376: ...edge and USB Keyboard platforms Control Character 00 Characters from 00 to 0x1F are sent as control character Ctrl Keys special keys are located from 0x80 to 0xA1 Control Character 01 Characters from...

Страница 377: ...EOT C D ENQ C S E ACK C S F BEL C S G BS C S H HT TAB LF C S J VT C S K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S...

Страница 378: ...X6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keypd Enter Ins Pg Up 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I...

Страница 379: ...A 091 A 092 A 093 A 094 A 095 6x A 096 A 097 A 098 A 099 A 100 A 101 A 102 A 103 A 104 A 105 A 106 A 107 A 108 A 109 A 110 A 111 7x A 112 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122 A...

Страница 380: ...12 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122 A 123 A 124 A 125 A 126 A 127 8x A 0128 A 0129 A 0130 A 0131 A 0132 A 0133 A 0134 A 0135 A 0136 A 0137 A 0138 A 0139 A 0140 A 0141 A 0142...

Страница 381: ...AB LF C S J VT C S K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS C RS C S US C...

Страница 382: ...er is 02 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Cl Cl BS Tab S Tab Enter Keypd Enter Ins 1x F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M...

Страница 383: ...Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS C RS C S US C S _ 2x Space 3x 0 1 2 3 4 5 6 7...

Страница 384: ...3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keypd Enter Ins Pg Up 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E...

Страница 385: ...K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS C RS C S US C S _ 2x Space 3x 0...

Страница 386: ...x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keypd Enter Ins Pg Up 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G...

Страница 387: ...M PD7100 Corded Microsoft Windows Codepage 1252 Windows 1252 is a character encoding of the Latin alphabet used by default in the leg acy components of Microsoft Windows in English and some other West...

Страница 388: ...Microsoft Windows Codepage 1252 Product Reference Guide 377 NOTES...

Страница 389: ...378 PowerScanTM PD7100 Corded NOTES...

Страница 390: ...Code 39 98 CTS 50 D Decode Capability 336 Defaults 339 Depth of Field 335 Dimensions 335 Drop Specifications 336 E eading trailing noise 99 Electrical Safety 336 EMI RFI 336 Error Codes 355 Errors 355...

Страница 391: ...25 26 Read Beeper Volume Good 28 Request to Send 50 Roll Tilt Tolerance 335 RS 232 interface selection 12 RS 232 Serial Connection 6 RTS 50 S sample bar codes code 128 357 code 39 357 interleaved 2 o...

Страница 392: ...14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP 0 1 2 3 4 5 6 7 8 9 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F A B C D E F G H I J K L M N O P Q R S T U V...

Страница 393: ...Datalogic Scanning KK Telephone 81 0 3 3491 6761 japan scanning datalogic com Latin America Datalogic Scanning Inc Telephone 305 591 3222 latinamerica scanning datalogic com Singapore Datalogic Scann...

Отзывы: