INTRODUCTION
27
2
The reader network is ready.
2.3.2 ID-NET™
Slave
Management Through Master
When an ID-NET™ layout has already been configured, it is possible to modify the
configuration of any Slave from VisiSet through the Master.
This feature requires a
minimum ID-NET™ Network Baud Rate of 38400
.
1. Connect a PC equipped with VisiSet™ to the Main, or Auxiliary interface of the Master
reader.
2. Launch VisiSet™ and connect to the Master reader.
3. From the VisiSet™ Device Menu select "ID-NET™ Status Window" and click on the
"Look For Devices On Network" button to check the status of the expected Slave devices
within the ID-NET™ network.
4. Click anywhere in the row of the specific slave in the ID-NET Status Window when its
Current Status is "Present". The Parameter Setup window will be displayed after a time
based on the network speed, with the configuration of the selected slave.
5. From the specific Slave Parameter Setup Window, change any parameter (not in
interactive mode), save the configuration to a file, or load a configuration from a file.
6. Send the modified configuration to the slave.
Содержание Matrix 450
Страница 1: ...MATRIX 450 Reference Manual...
Страница 12: ...xii...
Страница 133: ...SOFTWARE CONFIGURATION 121 8 Figure 102 Options Communication Serial Port Figure 103 Options Communication Ethernet...
Страница 160: ...www automation datalogic com...