BM150 Display Module Configuration and Messages
Product Reference Guide
185
Reading Mask/Device State (Master Only):
X = Recognized code label data (or "No Read" or "Multiple Read")
Y = Phase Counter (range: 0000000 to 9999999)
Z = Good Read or Multiple Read counters (%)
S = Reading Mask for Stand Alone or Master plus Slave readers 1 - 15
(0 = No Read, 1 = Good Read, M = Multiple Read)
U = Diagnostic condition for Stand Alone or Master plus Slave readers 1 - 15:
* = reader OK
- = reader not detected at startup
? = reader detected at startup but not responding to diagnostic polling
! = reader diagnostic error
BM150 Backup and Restore Procedure
The Backup and Restore functions are valid for any application layout type
(point-to-point, network, etc.) using CBX500 connection boxes through the
BM100 Backup module (required accessory for BM150 installation).
The Backup and Restore functions are managed through the BM150 display and
keypad and therefore are disabled at the BM100 Backup/Restore button.
If it ever becomes necessary to replace the reading device it can be quickly
configured through the restore procedure.
BM150 provides complete backup and restore functions (Configuration and
Environmental parameters) with the following difference:
For Single Readers or individual ID-NET Slaves:
• Backup and Restore functions provide parameter storage including all con-
figuration jobs present on the reader.
For Master Readers in ID-NET Master/Slave networks:
• Backup and Restore functions provide parameter storage of only the Startup
Configuration for the Master and all Slaves present in the network.
CAUTION
For Master/Slave networks any other configurations (jobs) stored in the device mem-
ory will not be backed up. Therefore upon a restore, all jobs other than the startup
configuration will be overwritten (erased). It is strongly recommended to save all con-
figurations to backup files.
Содержание Matrix 300N
Страница 1: ...Matrix 300N Product Reference Guide Image Based Reader...
Страница 72: ...Installation 56 Matrix 300N Figure 28 Mounting Bracket Overall Dimensions mm inch...
Страница 86: ...CBX Electrical Connections 70 Matrix 300N Figure 43 ID NET Network Connections with Common Power Branch Network...
Страница 87: ...ID NET Interface Product Reference Guide 71 Figure 44 ID NET Network Connections with Common Power Star Network...
Страница 91: ...Inputs Product Reference Guide 75 Figure 48 NPN External Trigger Using Matrix 300N Power...
Страница 153: ...Reader Configuration Product Reference Guide 137 Figure 84 Decoding Results OK...
Страница 180: ...ID NET Master ID NET Slave 1 ID NET Slave 1 Software Configuration 164 Matrix 300N...
Страница 182: ...Software Configuration 166 Matrix 300N Open the cloned application job...
Страница 216: ...DPM Data Matrix and QR codes on metal surfaces Non polarized Polarized Illuminators 200 Matrix 300N...
Страница 246: ......
Страница 247: ......