GRYPHON™
142
5.2.5
Inter-Block Delay
For the PEN Emulation interface, data are sent to the Host in fixed size blocks of 20
characters each. The inter-block delay parameter allows setting a delay between
each block sent to the Host.
5.3 IBM 46XX PARAMETERS
5.3.1
IBM Data Formatting (Transmission Format)
The IBM 46xx series cash register recognizes the following codes:
•
EAN 8/ EAN 13 / UPC A / UPC E with and without Add On
•
Interleaved 2/5
•
Code 39
•
Codabar
•
Code 128
•
Code 93
•
Normal 2/5
The transmission format of codes belonging to this set is specified by the protocol. As
the reader allows a wider set of codes to be selected, the following formats are
defined to offer the user all the reading possibilities of the Datalogic products.
Conversion to Code 39 Format
Data from any code selected may be transmitted. Each code is transmitted to the
Host as Code 39. Any character not included in the standard Code 39 set will be
replaced with a “Space” (20 Hex).
IBM Standard Format
Only codes belonging to the above mentioned set may be transmitted. Each code
transmitted to the Host is recognized by the identifier requested by the protocol. If the
selected code does not belong to this set, it will not be transmitted.
Mixed IBM St Code 39 Format
Data from any code selected may be transmitted. For codes belonging to the above
mentioned set, the “IBM Standard Format” is applied. The “Code 39” format applies
to codes not belonging to this set.
Содержание GRYPHON
Страница 12: ...GRYPHON 4 2 3 RS232 CONNECTION 2 4 USB ...
Страница 13: ...INSTALLATION 5 2 5 IBM USB POS 2 6 WEDGE CONNECTION ...
Страница 14: ...GRYPHON 6 2 7 PEN EMULATION CONNECTION ...
Страница 67: ...59 ...
Страница 76: ...Enter Configuration Exit and Save Configuration Ì Î DATA FORMAT Ì Î 68 ...
Страница 86: ...Enter Configuration Exit and Save Configuration Ì Î POWER SAVE Ì Î 78 ...
Страница 98: ...90 ...
Страница 120: ...Enter Configuration Exit and Save Configuration Ì Î CODE SELECTION Ì Î 112 ...
Страница 126: ...Enter Configuration Exit and Save Configuration Ì Î ADVANCED FORMATTING Ì Î 118 OR any code length ÌHC001Î ...
Страница 138: ...Exit and Save Configuration ADVANCED FORMATTING Ì Î 130 end Format 4 definition ÌHM3uÎ ...