background image

Sample Bar Codes

Product Reference Guide

                           287

GS1 DataBar™ 

GS1 DataBar™ 14

GS1 DataBar™ Expanded

GS1 DataBar™ Limited

GS1 DataBar™ Truncated

GS1 DataBar™ Stacked

(01)12345678901231

GS1 DataBar™ Omnidirectional Stacked

(01)12345678901231

GS1 DataBar™ Expanded Stacked

0123456789012313

GS1 DataBar™ variants must be enabled to read the bar codes below (see  "

GS1 DataBar™ 

Omnidirectional" on page 150

).

Содержание Gryphon I GPS4400

Страница 1: ...Gryphon I GPS4400 Product Reference Guide On Counter Presentation Scanner...

Страница 2: ...ing your Datalogic representative Electronic versions may either be downloadable from the Dat alogic website www datalogic com or provided on appropriate media If you visit our website and would like...

Страница 3: ...0 Configuring Other Features 10 Software Version Transmission 10 Resetting the Product Configuration to Defaults 11 CONFIGURATION USING BAR CODES 13 Configuration Parameters 13 GLOBAL INTERFACE FEATUR...

Страница 4: ...eout 62 LED AND BEEPER INDICATORS 63 Power On Alert 63 Good Read When to Indicate 63 Good Read Beep Type 64 Good Read Beep Frequency 64 Good Read Beep Length 65 Good Read Beep Volume 66 Good Read LED...

Страница 5: ...ice Weight Check 93 UPC EAN Quiet Zones 94 ADD ONS 95 Optional Add ons 95 Optional Add On Timer 96 Optional GS1 128 Add On Timer 99 CODE 39 102 Code 39 Enable Disable 102 Code 39 Check Character Calcu...

Страница 6: ...nable Disable 128 Standard 2 of 5 Check Character Calculation 128 Standard 2 of 5 Check Character Transmission 129 Standard 2 of 5 Length Control 129 Standard 2 of 5 Set Length 1 130 Standard 2 of 5 S...

Страница 7: ...Transmission 158 Code 93 Length Control 159 Code 93 Set Length 1 160 Code 93 Set Length 2 161 Code 93 Quiet Zones 162 MSI 162 MSI Enable Disable 162 MSI Check Character Calculation 163 MSI Check Char...

Страница 8: ...cro QR Code Length Control 196 Micro QR Code Set Length 1 197 Micro QR Code Set Length 2 198 UCC COMPOSITE 199 UCC Composite Enable Disable 199 UCC Optional Composite Timer 200 POSTAL CODE SELECTION 2...

Страница 9: ...EYPAD 289 HOST CONFIGURATION RESERVED CHARACTERS 291 SCANCODE TABLES 293 Control Character Emulation 293 Single Press and Release Keys 293 Interface Type PC AT PS 2 USB Keyboard or USB Keyboard for AP...

Страница 10: ...Contents viii Gryphon GPS4400 NOTES...

Страница 11: ...hapter 4 Software Configuration Strings provides background information and detailed instructions for more complex programming items Chapter 5 References provides background information and detailed i...

Страница 12: ...vely printed copies or product support CDs for most products can be purchased through your Datalogic reseller Technical Support Datalogic Website Support The Datalogic website www datalogic com is the...

Страница 13: ...Datalogic s patented Green Spot technology as well as supporting advanced features like image capture User comfort is maximized with the bar code scanner s steady deep red illumination light Easier on...

Страница 14: ...re some exceptions to the typical programming sequence described above Please read the description and setting instructions carefully when configuring each programmable feature Datalogic Aladdin Progr...

Страница 15: ...in its original shipping container Setting Up the Reader Follow the steps provided in this section to connect and get your reader up and communicating with its host 1 Begin by connecting the scan modu...

Страница 16: ...own in Figure 1 If the terminal will not support POT Power Off the Terminal to supply reader power use the approved power supply AC Adapter Plug the AC Adapter barrel connector into the socket on the...

Страница 17: ...the stand and push down to snap in place To remove just pull straight up to detach the reader from the stand For product dimensional information see Technical Specifications on page 263 and GPS4400 D...

Страница 18: ...n for your interface type in Configuration Using Bar Codes starting on page 13 also listed beside each interface type in Table 1 Unlike some programming features and options interface selec tions requ...

Страница 19: ...Alternate Keyboard USB Keyboard with alternate key encoding USB Com to simulate RS 232 standard interface P HA47 P CR Select USB COM STDa a Download the correct USB Com driver from www datalogic com S...

Страница 20: ...quires different programming than the standard fac tory default settings the following sections of this manual allow configura tion of non interface specific settings you might require Reading Paramet...

Страница 21: ...orrect interface before scanning this label Restore Factory Configuration If you want to restore the Factory Configuration for your imager scan either the Restore USA Factory Configuration bar code or...

Страница 22: ...Setup Custom Configuration Settings 12 Gryphon GPS4400 NOTES...

Страница 23: ...s and select the inter face for your application The following configuration parameters are divided into logical groups making it easy to find the desired function based on its reference group Interfa...

Страница 24: ...ly the facing page to ensure that the reader reads only the bar code you intend to scan 3 If additional input parameters are needed go to Appendix D Keypad and scan the appropriate characters from the...

Страница 25: ...ypes Host Commands Obey Ignore This option specifies whether the reader will obey or ignore host com mands When set to ignore the reader will ignore all host commands except those necessary for servic...

Страница 26: ...Enter Exit Programming Mode Configuration Using Bar Codes 16 Gryphon GPS4400 NOTES...

Страница 27: ...amming bar codes in this section if modifications to the standard RS 232 interface settings are necessary to meet your system s requirements Additional settings which apply to both the RS 232 and USB...

Страница 28: ...Rate See page 232 for information on this feature CR2BA00 CR Baud Rate 1200 CR2BA01 CR Baud Rate 2400 CR2BA02 CR Baud Rate 4800 CR2BA03 CR Baud Rate 9600 DEFAULT CR2BA04 CR Baud Rate 19 200 CR2BA05 CR...

Страница 29: ...nterface with devices requiring a 7 bit or 8 bit ASCII protocol for sending and receiving data CR2DA00 CR 7 Data Bits CR2DA01 CR 8 Data Bits DEFAULT Stop Bits Set the number of stop bits to match host...

Страница 30: ...on GPS4400 Parity This feature specifies parity required for sending and receiving data Select the parity type according to host device requirements See page 232 for more information DEFAULT CR2PA00 C...

Страница 31: ...ing Control DEFAULT CR2HC00 CR Handshaking Control RTS CR2HC01 CR Handshaking Control RTS CTS CR2HC02 CR Handshaking Control RTS XON XOFF CR2HC03 CR Handshaking Control RTS On CTS CR2HC04 CR Handshaki...

Страница 32: ...RACTER on page 25 ACK NAK TIMEOUT VALUE on page 26 ACK NAK RETRY COUNT on page 26 ACK NAK ERROR HANDLING on page 27 INDICATE TRANSMISSION FAILURE on page 27 DISABLE CHARACTER on page 28 ENABLE CHARACT...

Страница 33: ...AMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric char acters in Appendix D Keypad representing your desired character s End by scanning the ENTER EXIT...

Страница 34: ...e Disable DEFAULT CBPNF01 CR Beep On Not On File Enable ACK NAK Options This enables disables the ability of the reader to support the RS 232 ACK NAK protocol See page 234 for more information DEFAULT...

Страница 35: ...mands conflicts with normal operation of these characters 8 bit data is not recognized when the option Data Bits has been set as 7 Data Bits NAK Character This setting specifies an ASCII character or...

Страница 36: ...stake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning CANCEL DEFAULT 01 ACK NAK Timeout value is 200ms ACK NAK Retry Count Specifies the numbe...

Страница 37: ...rror Handling Ignore Errors Detected CR2EH01 CR ACK NAK Error Handling Process Error as Valid ACK Character CR2EH02 CR ACK NAK Error Handling Process Error as Valid NAK Character Indicate Transmission...

Страница 38: ...e page 238 for more information on setting this feature CR2DC Select Disable Character Setting DEFAULT 0x44 Disable Character is D Enable Character Specifies the value of the RS 232 host command used...

Страница 39: ...EED on page 36 USB KEYBOARD NUMERIC KEYPAD on page 37 Use the programming bar codes in this chapter to select options for USB Keyboard Interface Reference Appendix B Standard Defaults for a listing of...

Страница 40: ...try Mode U S CKBCO01 CR Country Mode Belgium CKBCO02 CR Country Mode Britain CKBCO11 CR Country Mode Croatia Supports only the interfaces listed in the Country Mode feature description Supports only t...

Страница 41: ...in the Country Mode feature description CKBCO13 CR Country Mode French Canadian CKBCO05 CR Country Mode Germany Supports only the interfaces listed in the Country Mode feature description CKBCO0D CR C...

Страница 42: ...CKBCO12 CR Country Mode Poland Supports only the interfaces listed in the Country Mode feature description Supports only the interfaces listed in the Country Mode feature description CKBCO08 CR Count...

Страница 43: ...gramming Mode Product Reference Guide 33 Country Mode continued CKBCO09 CR Country Mode Spain KBCO0A CR Country Mode Sweden CKBCO0B CR Country Mode Switzerland Supports only the interfaces listed in t...

Страница 44: ...sent as control character Ctrl Keys special keys are located from 0x80 to 0xA1 Control Character 01 Characters from 00 to 0x1F are sent as control character Ctrl Shift special keys are located from 0x...

Страница 45: ...d examples for set ting this feature CKBID Set Intercode Delay To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the...

Страница 46: ...es the USB poll rate for a USB keyboard DEFAULT CKBSP01 CR USB Keyboard Speed 1ms CKBSP02 CR USB Keyboard Speed 2ms CKBSP03 CR USB Keyboard Speed 3ms CKBSP04 CR USB Keyboard Speed 4ms CKBSP05 CR USB K...

Страница 47: ...Keyboard Speed 10ms USB Keyboard Settings Enter Exit Programming Mode Product Reference Guide 37 USB Keyboard Speed continued USB Keyboard Numeric Keypad This option Controls whether numeric characte...

Страница 48: ...Enter Exit Programming Mode USB Keyboard Settings 38 Gryphon GPS4400 NOTES...

Страница 49: ...ture settings for USB interfaces differ depending upon which host type the reader will be connected with Use the feature settings in this chapter to specifically configure for the USB OEM interface Ot...

Страница 50: ...what other scanners you may already have connected to a USB OEM POS you may need to change this setting to enable all devices to communicate Options are Table Top Scanner Handheld Scanner CIBUT00 CR...

Страница 51: ...or verified to be valid for Code 39 Options are Code 39 Format Translate the following symbologies to Code 39 USB OEM Code128 Code 93 and Codabar DEFAULT CIBC300 CR Transmit Labels in Code 39 Format...

Страница 52: ...USB OEM Interface 42 Gryphon GPS4400 NOTES...

Страница 53: ...ction 2D Symbologies NO READ MESSAGE starting on page 55 NO READ STRING starting on page 55 CODE VERIFIER MODE starting on page 56 Code Verifier Mode Match String Wrong Code String CASE CONVERSION on...

Страница 54: ...ENTER EXIT PROGRAMMING MODE bar code above to place the unit in Programming Mode then the Set Global Prefix or Set Global Suffix bar code followed by the digits in hex from the Alphanumeric character...

Страница 55: ...lows A close brace character ASCII followed by A code character see some samples in the table below followed by A modifier character the modifier character is symbol dependent DEFAULT CAIEN00 CR Globa...

Страница 56: ...X 58 I2OF5 I 49 IATA INDUSTRIAL 2OF5 X 58 INDUSTRIAL 2OF5 X 58 ISBN X 58 ISBT128 CONCAT X 58 ISSN X 58 MAXICODE U 55 MICRO QR Q 51 MICRO PDF L 4C MSI M 4D PDF417 L 4C PLESSEY P 50 POSTAL AUSTRALIAN X...

Страница 57: ...ID individually for the GS1 128 symbology and the programming for this works the same way as Label ID See Label ID Set Individually Per Symbology starting on page 249 for detailed instructions on set...

Страница 58: ...page 246 of References for more information on setting this feature Label ID Pre Loaded Sets The reader supports two pre loaded sets of Label IDs See Label ID Pre loaded Sets starting on page 246 for...

Страница 59: ...ng on page 50 to select the symbology you want to set followed by up to 3 charac ters from the ASCII Chart at the back of this manual See Label ID Set Individ ually Per Symbology on page 249 for detai...

Страница 60: ...Mode Set ABC Codabar Label ID Character s CP3ID Set Code 32 Pharmacode Label ID Character s CALID Set Anker Plessey Label ID Character s CC9ID Set Code 93 Label ID Character s CPAID Set Australian Pos...

Страница 61: ...site Label ID Character s CU8ID Set GS1 128 Label ID Character s C82ID Set EAN 8 P2 Label ID Character s CUMID Set GS1 128 Composite Label ID Character s C85ID Set EAN 8 P5 Label ID Character s CLBID...

Страница 62: ...B Postal Code Label ID Character s CMSID Set MSI Label ID Character s CU2ID Set Industrial 2 of 5 Label ID Character s CPPID Set Planet Postal Code Label ID Character s CI2ID Set Interleaved 2 of 5 La...

Страница 63: ...Postal Code Label ID Character s CAMID Set UPC A Composite Label ID Character s CS2ID Set Standard 2 of 5 Label ID Character s CA2ID Set UPC A P2 Label ID Character s CPSID Set Swedish Postal Code La...

Страница 64: ...417 Label ID Character s CCFID Set Codablock F Label ID Character s CMIID Set Micro PDF 417 Label ID Character s CDMID Set Data Matrix Label ID Character s CQRID Set QR Code Label ID Character s CMQID...

Страница 65: ...Line Modes only It allows up to 20 characters from the set of ASCII characters or any hex value from 00 to FE CNORS Select No Read String To configure this feature scan the ENTER EXIT PROGRAMMING MOD...

Страница 66: ...String then it is sent to the host through the configured port If it does not match the code verifier Match String you can specify whether to send either the Wrong Code or a defined Wrong String messa...

Страница 67: ...ollowed by the digits in hex from the Alphanumeric characters in Appen dix D on page 289 representing your desired character s End by scanning the ENTER EXIT barcode again Make a mistake Scan the CANC...

Страница 68: ...tted to the host as it has been decoded or after the reading phase has been deactivated Phase Off CLFTX00 r Phase Off DEFAULT CLFTX01 r On Decode Advanced Formatting User Label Edit Advanced formattin...

Страница 69: ...fix or other appended data Character Conversion Character conversion is an eight byte configuration item The eight bytes are 4 character pairs represented in hexadecimal ASCII values The first charact...

Страница 70: ...Enter Exit Programming Mode Data Format 60 Gryphon GPS4400 NOTES...

Страница 71: ...73 PHASE OFF EVENT on page 69 GREEN SPOT DURATION on page 74 PHASE OFF TIMEOUT on page 69 MOBILE PHONE MODE on page 74 SERIAL START CHARACTER on page 70 MOBILE BIAS on page 75 SERIAL STOP CHARACTER o...

Страница 72: ...l for each label read The timeout can be set within a range of 20 milliseconds to 2 550 milliseconds 2 55 seconds in 10ms increments CSNDR0A CR Double Read Timeout 0 1 Second CSNDR32 CR Double Read Ti...

Страница 73: ...ower On Alert Disable No Audible Indication CBPPU01 CR Power On Alert Power up Beep DEFAULT Good Read When to Indicate This feature specifies when the reader will provide indication beep and or flash...

Страница 74: ...0 CR Good Read Beep Type Mono CBPTY01 CR Good Read Beep Type Bitonal Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low medium or high frequency selectable from the list...

Страница 75: ...ep Length 60 msec CBPLE08 CR Good Read Beep Length 80 msec DEFAULT CBPLE0A CR Good Read Beep Length 100 msec CBPLE0C CR Good Read Beep Length 120 msec CBPLE0E CR Good Read Beep Length 140 msec CBPLE10...

Страница 76: ...d Beep Volume Selects the beeper volume loudness upon a good read beep There are three selectable volume levels CBPVO00CR Good Read Beep Volume Beeper Off CBPVO01CR Good Read Beep Volume Low CBPVO02CR...

Страница 77: ...detailed instructions and examples for setting this feature CLAGL00 CR Good Read LED Duration Setting Keep LED on until next trigger push CLAGL Select Good Read LED Duration Setting To configure this...

Страница 78: ...n GPS4400 SCANNING FEATURES Operating Mode Selects the reader s scan operating mode See page 256 in References for descriptions CSNRM00 r On Line Single Trigger CSNRM01 r Serial On Line CSNRM02 r Auto...

Страница 79: ...als CSNET Scanning Active Time To configure this feature scan the ENTER EXIT PRO GRAMMING MODE barcode above then the barcode at left followed by the digits in hex from the Alphanu meric characters in...

Страница 80: ...er is 02 STX See page 256 in References for more information Serial Stop Character CSTOF Select Serial Stop Characters To configure this feature scan the ENTER EXIT PRO GRAMMING MODE barcode above the...

Страница 81: ...ng phase When disabled the trigger can still be activated once by pressing and holding the trigger for 5 sec onds to enter Debug Mode DEFAULT CSOTM00 Manual Trigger Control Disable CSOTM01 Manual Trig...

Страница 82: ...ve Time 3 seconds CSNET05 CR Scanning Active Time 5 seconds DEFAULT CSNET08 CR Scanning Active Time 8 seconds Scanning Active Time works in On Line and Serial On Line Read modes as the Timeout Phase O...

Страница 83: ...The range for this setting is from 1 to 255 seconds in 1 second increments See page 259 in References DEFAULT LSTM00 Aiming Off After Decoding LSTM Set Aiming Duration Timer To configure this feature...

Страница 84: ...Off CLSSP01 CR Green Spot Duration Short 300 msec DEFAULT CLSSP02 CR Green Spot Duration Medium 500 msec CLSSP03 CR Green Spot Duration Long 800 msec Mobile Phone Mode This mode is useful for scannin...

Страница 85: ...RAMMING MODE bar code above then the bar code at left fol lowed by the digits from the Alphanumeric characters in Appendix D Keypad representing your desired character s End by scanning the ENTER EXIT...

Страница 86: ...74 For additional options see the Aladdin configuration application Unlike some programming features and options Decode Negative Image selections require that you scan only one programming bar code la...

Страница 87: ...de is enabled the scanner keeps on processing the image until all the labels present are decoded The reader then sorts the data from all the bar codes if configured to do so before transmitting it Mul...

Страница 88: ...code above then the bar code at left fol lowed by the digits from the Alphanumeric characters in Appendix D Keypad representing your desired character s End by scanning the ENTER EXIT bar code Make a...

Страница 89: ...onal page 150 Code 39 CIP French Pharmaceutical page 110 GS1 DataBar Expanded page 151 Code 39 Danish PPT page 110 GS1 DataBar Limited page 156 Code 39 LaPoste page 111 Code 93 page 157 Code 39 PZN pa...

Страница 90: ...1D Symbologies 80 Gryphon GPS4400 4 Complete the programming sequence by scanning the ENTER EXIT PROGRAMMING bar code to exit Programming Mode DISABLE ALL SYMBOLOGIES Use this feature to disable all...

Страница 91: ...Control This feature is used to control the reader s method of processing coupon labels CCPLC00 CR Coupon Control Allow all coupon bar codes to be decoded CCPLC01 CR Coupon Control Enable only UPCA c...

Страница 92: ...en disabled the reader will not read UPC A bar codes CABEN00 CR UPC A Disable CABEN01 CR UPC A Enable DEFAULT UPC A Check Character Transmission Enable this option to transmit the check character alon...

Страница 93: ...the symbology ID to match those required for EAN 13 DEFAULT CAB3B00 CR UPC A to EAN 13 Don t Expand CAB3B01 CR UPC A to EAN 13 Expand UPC A Number System Character Transmission This feature enables d...

Страница 94: ...a base label of this symbology is decoded DEFAULT CAB2D00 CR EAN 13 2D Component Disable 2D component not required CAB2D01 CR EAN 13 2D Component 2D component must be decoded UPC E The following opti...

Страница 95: ...T00 CR UPC E Check Character Transmission Don t Send CEBCT01 CR UPC E Check Character Transmission Send DEFAULT UPC E 2D Component This feature enables disables a requirement that a 2D label component...

Страница 96: ...format Selecting this feature also changes the symbology ID to match those required for EAN 13 DEFAULT CEB3B00 CR UPC E to EAN 13 Don t Expand CEB3B01 CR UPC E to EAN 13 Expand Expand UPC E to UPC A E...

Страница 97: ...transmit CEBNS01 CR UPC E Number System Character Transmit DEFAULT GTIN FORMATTING This feature enables disables the ability to convert UPC E UPC A EAN 8 and EAN 13 labels into the GTIN 14 character...

Страница 98: ...hen disabled the reader will not read EAN 13 JAN 13 bar codes C3BEN00 CR EAN 13 Disable C3BEN01 CR EAN 13 Enable DEFAULT EAN 13 Check Character Transmission Enable this option to transmit the check ch...

Страница 99: ...character is the first character of the label C3BF100 CR EAN 13 Flag 1 Char Don t transmit C3BF101 CR EAN 13 Flag 1 Char Transmit DEFAULT EAN 13 ISBN Conversion This option enables disables conversion...

Страница 100: ...of this symbology is decoded DEFAULT C3B2D00 CR EAN 13 2D Component Disable 2D component not required C3B2D01 CR EAN 13 2D Component 2D component must be decoded ISSN The following options apply to th...

Страница 101: ...able When disabled the reader will not read EAN 8 JAN 8 bar codes C8BEN00 CR EAN 8 Disable C8BEN01 CR EAN 8 Enable DEFAULT EAN 8 Check Character Transmission Enable this option to transmit the check c...

Страница 102: ...B3B00 CR Expand EAN 8 to EAN 13 Disable C8B3B01 CR Expand EAN 8 to EAN 13 Enable EAN 8 2D Component This feature enables disables a requirement that a 2D label component be decoded when a base label f...

Страница 103: ...r each feature description UPC EAN Price Weight Check This feature enables disables calculation and verification of price weight check digits DEFAULT CPWEN00 CR Price Weight Check Disabled CPWEN01 CR...

Страница 104: ...t zones for UPC EAN labels Quiet zones are blank areas at the ends of a bar code typically 10 times the width of the narrowest bar or space in the label The property applies to all EAN UPC symbologies...

Страница 105: ...CADO201 CR Optional Add Ons Enable P2 DEFAULT CADO500 CR Optional Add Ons Disable P5 CADO501 CR Optional Add Ons Enable P5 DEFAULT CADO800 CR Optional Add Ons Disable GS1 128 CADO801 CR Optional Add...

Страница 106: ...ok for an add on when an add on fragment has been seen and optional add ons are enabled Also see Optional GS1 128 Add On Timer on page 99 CADOT01 CR Optional Add On Timer 10ms CADOT02 CR Optional Add...

Страница 107: ...70ms DEFAULT CADOT0A CR Optional Add On Timer 100ms CADOT0C CR Optional Add On Timer 120ms CADOT0E CR Optional Add On Timer 140ms CADOT10 CR Optional Add On Timer 160ms 1D Symbologies Enter Exit Prog...

Страница 108: ...16 CR Optional Add On Timer 220ms CADOT18 CR Optional Add On Timer 240ms CADOT1A CR Optional Add On Timer 260ms CADOT1C CR Optional Add On Timer 280ms CADOT1E CR Optional Add On Timer 300ms Enter Exit...

Страница 109: ...ar EAN UPC part For UPC EAN add ons other than those of that type see Optional Add On Timer on page 96 DEFAULT CADUT00 CR Optional GS1 128 Add On Timer Disable CADUT01 CR Optional GS1 128 Add On Timer...

Страница 110: ...70ms CADUT0A CR Optional GS1 128 Add On Timer 100ms CADUT0C CR Optional GS1 128 Add On Timer 120ms CADUT0E CR Optional GS1 128 Add On Timer 140ms CADUT10 CR Optional GS1 128 Add On Timer 160ms Enter E...

Страница 111: ...S1 128 Add On Timer 220ms CADUT18 CR Optional GS1 128 Add On Timer 240ms CADUT1A CR Optional GS1 128 Add On Timer 260ms CADUT1C CR Optional GS1 128 Add On Timer 280ms CADUT1E CR Optional GS1 128 Add O...

Страница 112: ...eck Character Calculation Enable this option to enables disables calculation and verification of an optional Code 39 check character When disabled any check character in the label is treated as a data...

Страница 113: ...cter along with Code 39 bar code data CC3CT00 CR Code 39 Check Character Transmission Don t Send CC3CT01 CR Code 39 Check Character Transmission Send DEFAULT Code 39 Check Character Calculation contin...

Страница 114: ...de 39 start and stop characters DEFAULT CC3SS00 CR Code 39 Start Stop Character Transmission Don t Transmit CC3SS01 CR Code 39 Start Stop Character Transmission Transmit Code 39 Full ASCII Enables dis...

Страница 115: ...39 Quiet Zones Quiet Zones on two sides CC3LO03 CR Code 39 Quiet Zones Small Quiet Zones on two sides DEFAULT Code 39 Length Control This feature specifies either variable length decoding or fixed len...

Страница 116: ...tting Length 1 See page 241 for detailed instructions on setting this feature Table 3 Code 39 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Characters 07 Characters 15 Characters...

Страница 117: ...examples for setting Length 2 See page 241 for detailed instructions on setting this feature Table 4 Code 39 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Ignore This Length 07 C...

Страница 118: ...Enable Disable DEFAULT CCTEN00 CR Trioptic Code Disable CCTEN01 CR Trioptic Code Enable CODE 32 ITAL PHARMACEUTICAL CODE The following options apply to the Code 32 Italian Pharmaceutical Code symbolo...

Страница 119: ...eck Char Transmission Enable this option to transmit the check character along with Code 32 bar code data DEFAULT CP3CT00 CR Code 32 Check Character Transmission Don t Send CP3CT01 CR Code 32 Check Ch...

Страница 120: ...les Disables ability of the reader to decode Code 39 CIP labels DEFAULT CCCEN00 CR Code 39 CIP Disable CCCEN01 CR Code 39 CIP Enable CODE 39 DANISH PPT The following options apply to the Code 39 Danis...

Страница 121: ...es disables the ability of the scanner to decode Code39 La Poste labels DEFAULT CLPEN00 CR Code 39 LaPoste Disable CLPEN01 CR Code 39 LaPoste Enable CODE 39 PZN The following options apply to the Code...

Страница 122: ...28 Enable Disable When disabled the reader will not read Code 128 bar codes CC8EN00 CR Code 128 Disable CC8EN01 CR Code 128 Enable DEFAULT Expand Code 128 to Code 39 This feature enables disables expa...

Страница 123: ...bar code data DEFAULT CC8CT00 CR Code 128 Check Character Transmission Don t Send CC8CT01 CR Code 128 Check Character Transmission Send Code 128 Function Character Transmission Enables disables trans...

Страница 124: ...e Exchange Transmission Disable CC8SC01 CR Code 128 Sub Code Exchange Transmission Enable Code 128 Quiet Zones This feature specifies the number of quiet zones for Code 128 labels Quiet zones are blan...

Страница 125: ...ode 128 Length Control This feature specifies either variable length decoding or fixed length decod ing for the Code 128 symbology See page 241 for more information DEFAULT CC8LC00 CR Code 128 Length...

Страница 126: ...g Length 1 See page 241 for detailed instructions on setting this feature Table 5 Code 128 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Character 07 Characters 15 Characters 80...

Страница 127: ...gth Table 6 provides examples for setting Length 2 See page 241 for detailed instructions on setting this feature Table 6 Code 128 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 I...

Страница 128: ...ansmit GS1 128 labels in Code 128 data format Transmit GS1 128 labels in GS1 128 data format Do not transmit GS1 128 labels CU8EN00CR GS1 128 Transmit in Code 128 data format CU8EN01CR GS1 128 Transmi...

Страница 129: ...disable ISBT128 concatenation of 2 labels DEFAULT CI8CE00 CR ISBN 128 Concatenation Disable CI8CE01 CR ISBN 128 Concatenation Enable ISBT 128 Force Concatenation When enabled this feature forces conc...

Страница 130: ...tenation Mode Specifies the concatenation mode between Static and Dynamic DEFAULT CI8CM00CR ISBT 128 Concatenation Mode Static CI8CM01CR ISBT 128 Concatenation Mode Dynamic This option is only valid w...

Страница 131: ...enation Timeout 100 msec DEFAULT CI8DT14 CR ISBT 128 Dynamic Concatenation Timeout 200 msec CI8DT32 CR ISBT 128 Dynamic Concatenation Timeout 500 msec CI8DT4B CR ISBT 128 Dynamic Concatenation Timeout...

Страница 132: ...2 Gryphon GPS4400 INTERLEAVED 2 OF 5 I 2 OF 5 The following options apply to the I 2 of 5 symbology I 2 of 5 Enable Disable When disabled the reader will not read I 2 of 5 bar codes DEFAULT CI2EN00 CR...

Страница 133: ...n utility or contact Technical Support DEFAULT CI2CC00 CR I 2 of 5 Check Character Calculation Disable CI2CC01 CR I 2 of 5 Check Character Calculation Check Standard Modulo 10 CI2CC02 CR I2of5CheckCha...

Страница 134: ...1 CR I 2 of 5 Check Character Transmission Send DEFAULT I 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decod ing for the I 2 of 5 symbology Variable Len...

Страница 135: ...Length 1 See page 241 for detailed instructions on setting this feature Table 7 I 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 2 Characters 6 Characters 14 Characters 50 Ch...

Страница 136: ...les for setting Length 2 See page 241 for detailed instructions on setting this feature Table 8 I 2 of 5 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting Ignore This Length 4 Character...

Страница 137: ...bles Disables ability of reader to decode Interleaved 2 of 5 CIP HR labels DEFAULT CCHEN00 CR Interleaved 2 of 5 CIP HR Disable CCHEN01 CR Interleaved 2 of 5 CIP HR Enable FOLLETT 2 OF 5 The following...

Страница 138: ...ill not read Standard 2 of 5 bar codes DEFAULT C2SEN00 CR Standard 2 of 5 Disable C2SEN01 CR Standard 2 of 5 Enable Standard 2 of 5 Check Character Calculation This option enables disables calculation...

Страница 139: ...Standard 2 of 5 Check Character Transmission Send DEFAULT Standard 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decod ing for the Standard 2 of 5 symbo...

Страница 140: ...ting Length 1 See page 241 if you want detailed instructions on setting this feature Table 9 Standard 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Character 07 Characters...

Страница 141: ...rovides examples for setting Length 2 See page 241 for detailed instructions on setting this feature Table 10 Standard 2 of 5 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting pad with...

Страница 142: ...f reader to decode Industrial 2 of 5 labels DEFAULT CU2EN00 CR Industrial 2 of 5 Disable CU2EN01 CR Industrial 2 of 5 Enable Industrial 2 of 5 Check Character Calculation Enables Disables calculation...

Страница 143: ...ial 2 of 5 Check Character Transmission Enable DEFAULT Industrial 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decod ing for the Industrial 2 of 5 symbo...

Страница 144: ...Length 1 See page 241 if you want detailed instructions on setting this feature Table 11 Industrial 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Characters 07 Characters...

Страница 145: ...this length only one fixed length Table 12 provides examples for setting Length 2 See page 241 for detailed instructions on setting this feature Table 12 Industrial 2 of 5 Length 2 Setting Examples S...

Страница 146: ...isables the ability of the reader to decode IATA labels DEFAULT CIAEN00 CR IATA Disable CIAEN01 CR IATA Enable IATA Check Character Transmission Enables Disables calculation and verification of an opt...

Страница 147: ...r Enable Codabar Check Character Calculation Enable this option to enables disables calculation and verification of an optional Codabar check character When disabled any check character in the label i...

Страница 148: ...CBCT00 CR Codabar Check Character Transmission Don t Send CCBCT01 CR Codabar Check Character Transmission Send DEFAULT Codabar Start Stop Character Transmission Enable this option to enable disable tr...

Страница 149: ...cter Set ABCD TN E CCBSC01 CR Codabar Check Character Set ABCD ABCD CCBSC02 CR Codabar Check Character Set abcd tn e CCBSC03 CR Codabar Check Character Set abcd abcd DEFAULT Codabar Start Stop Charact...

Страница 150: ...t Zones Quiet Zones on two sides CCBLO03 CR Codabar Quiet Zones Small Quiet Zones on two sides DEFAULT Codabar Length Control This feature specifies either variable length decoding or fixed length dec...

Страница 151: ...s Table 13 provides some examples for setting Length 1 See page 241 for detailed instructions on setting this feature Table 13 Codabar Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting...

Страница 152: ...his length only one fixed length Table 14 provides examples for setting Length 2 See page 241 for detailed instructions on setting this feature Table 14 Codabar Length 2 Setting Examples STEP ACTION E...

Страница 153: ...ar Enable Disable Enables Disables ability of reader to decode ABC Codabar labels DEFAULT CCBAB00 CR ABC Codabar Disable CCBAB01 CR ABC Codabar Enable ABC Codabar Concatenation Mode Specifies the conc...

Страница 154: ...nation Mode CCBDT05 CR ABC Codabar Dynamic Concatenation Timeout 50 msec CCBDT0A CR ABC Codabar Dynamic Concatenation Timeout 100 msec DEFAULT CCBDT14 CR ABC Codabar Dynamic Concatenation Timeout 200...

Страница 155: ...ng Mode Product Reference Guide 145 ABC Codabar Force Concatenation Forces labels starting or ending with D to be concatenated DEFAULT CCBFC00 CR ABC Codabar Force Concatenation Disable CCBFC01 CR ABC...

Страница 156: ...1EN00 CR Code 11 Disable CC1EN01 CR Code 11 Enable Code 11 Check Character Calculation This option enables disables calculation and verification of optional Code 11 check character CC1CC00 CR Code 11...

Страница 157: ...1CT01 CR Code 11 Check Character Transmission Send DEFAULT Code 11 Length Control This feature specifies either variable length decoding or fixed length decod ing for the Code 11 symbology Variable Le...

Страница 158: ...ength 1 See page 241 for detailed instructions on setting this feature Table 15 Code 11 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting pad with leading zeros 02 Characters 07 Charact...

Страница 159: ...16 provides examples for setting Length 2 See page 241 for detailed instructions on setting this feature Table 16 Code 11 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting pad with lea...

Страница 160: ...ader will not read GS1 DataBar Omnidirectional bar codes DEFAULT C4BEN00 CR GS1 DataBar Omnidirectional Disable C4BEN01 CR GS1 DataBar Omnidirectional Enable GS1 DataBar Omnidirectional GS1 128 Emulat...

Страница 161: ...GS1 DataBar Omnidirectional 2D Component Disable 2D component not required C4B2D01 CR GS1 DataBar Omnidirectional 2D Component 2D component must be decoded GS1 DATABAR EXPANDED The following options...

Страница 162: ...DEFAULT CXBU800 CR GS1 DataBar Expanded GS1 128 Emulation Disable CXBU801 CR GS1 DataBar Expanded GS1 128 Emulation Enable GS1 DataBar Expanded 2D Component This feature enables disables a requirement...

Страница 163: ...h decoding or fixed length decod ing for the GS1 DataBar Expanded symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed length decoding two differen...

Страница 164: ...ing Length 1 See page 241 for detailed instructions on setting this feature Table 17 GS1 DataBar Expanded Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Character 07 Characters 52...

Страница 165: ...18 provides examples for setting Length 2 See page 241 for detailed instructions on setting this feature Table 18 GS1 DataBar Expanded Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting...

Страница 166: ...hen disabled the reader will not read GS1 DataBar Limited bar codes DEFAULT CLBEN00 CR GS1 DataBar Limited Disable CLBEN01 CR GS1 DataBar Limited Enable GS1 DataBar Limited GS1 128 Emulation When enab...

Страница 167: ...abel of this symbology is decoded DEFAULT CLB2D00 CR GS1 DataBar Limited 2D Component Disable 2D component not required CLB2D01 CR GS1 DataBar Limited 2D Component 2D component must be decoded CODE 93...

Страница 168: ...isable CC9CC01 CR Code 93 Check Character Calculation Enable Check C CC9CC02 CR Code 93 Check Character Calculation Enable Check K CC9CC03 CR Code 93 Check Character Calculation Enable Check C and K D...

Страница 169: ...variable length decoding or fixed length decod ing for the Code 93 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding...

Страница 170: ...ng Length 1 See page 241 for detailed instructions on setting this feature Table 19 Code 93 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Characters 07 Characters 15 Characters 5...

Страница 171: ...gnore this length only one fixed length Table 20 provides examples for setting Length 2 See page 241 for detailed instructions on setting this feature Table 20 CODE 93 Length 2 Setting Examples STEP A...

Страница 172: ...Code 93 CC9LO02 CR Code 93 Quiet Zones Quiet Zones on two sides CC9LO03 CR Code 93 Quiet Zones Small Quiet Zones on two sides DEFAULT MSI The following options apply to the MSI symbology MSI Enable D...

Страница 173: ...racter Calculation Disable CMSCC01 CR MSI Check Character Calculation Enable Mod10 DEFAULT CMSCC02 CR MSI Check Character Calculation Enable Mod11 10 CMSCC03 CR MSI Check Character Calculation Enable...

Страница 174: ...variable length decoding or fixed length decod ing for the MSI symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two...

Страница 175: ...es for setting Length 1 See page 241 for detailed instructions on setting this feature Table 21 MSI Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Characters 07 Characters 15 Char...

Страница 176: ...ore this length only one fixed length Table 22 provides examples for setting Length 2 See page 241 for detailed instructions on setting this feature Table 22 MSI Length 2 Setting Examples STEP ACTION...

Страница 177: ...Enable Plessey Check Character Calculation Enables Disables calculation and verification of an optional Plessey check character CPLCC00 CR Plessey Check Character Calculation Disable CPLCC01 CR Pless...

Страница 178: ...ssey Check Character Transmission Enable DEFAULT Plessey Length Control This feature specifies either variable length decoding or fixed length decod ing for the Plessey symbology Variable Length For v...

Страница 179: ...for setting Length 1 See page 241 for detailed instructions on setting this feature Table 23 Plessey Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Characters 07 Characters 15 Ch...

Страница 180: ...e this length only one fixed length Table 24 provides examples for setting Length 2 See page 241 for detailed instructions on setting this feature Table 24 Plessey Length 2 Setting Examples STEP ACTIO...

Страница 181: ...most of the available 2D symbolo gies Default settings are indicated with a green arrow Also reference Appendix B Standard Defaults for a listing of the most widely used set of stan dard factory sett...

Страница 182: ...el The selectable range is 10 milliseconds to 2 55 milliseconds CDETM0A CR 2D Maximum Decoding Time 100 msec CDETM32 CR 2D Maximum Decoding Time 200 msec CDETM23 CR 2D Maximum Decoding Time 350 msec D...

Страница 183: ...disables ability of reader to append multiple 2D Codes labels in a structured format The structured append property is globally applied to the following symbologies if these are enabled Data Matrix Az...

Страница 184: ...y to all the 2D symbologies that support that feature according to Standard AIM Specification Data Matrix QR MicroQR Aztec and Chinese Sensible Code To decode all symbologies including linear symbolog...

Страница 185: ...Aztec Code Enable DEFAULT Aztec Code Length Control This feature specifies either variable length decoding or fixed length decod ing for this symbology Variable Length For variable length decoding a m...

Страница 186: ...with zeros See page 241 for detailed instructions on setting this feature CAZL1 Select Aztec Code Length 1 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then...

Страница 187: ...of 0001 pad with zeros See page 241 for detailed instructions on setting this feature CAZL2 Select Aztec Code Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code...

Страница 188: ...CR China Sensible Code Enable China Sensible Code Length Control This feature specifies either variable length decoding or fixed length decod ing for this symbology Variable Length For variable lengt...

Страница 189: ...0001 pad with zeros See page 241 for detailed instructions on setting this feature CCSL1 Select China Sensible Code Length 1 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar...

Страница 190: ...of 0001 pad with zeros See page 241 for detailed instructions on setting this feature CCSL2 Select China Sensible Code Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE...

Страница 191: ...e options available when reading Data Matrix with different form factors Choices are Square Style Rectangular Style Both Square and Rectangular Style The configuration item can also be configured as a...

Страница 192: ...Control Length 1 is the minimum label length if in Variable Length Mode or the first fixed length if in Fixed Length Mode Characters can be set from 0001 to 3 116 characters in increments of 0001 pad...

Страница 193: ...of 0001 pad with zeros See page 241 for detailed instructions on setting this feature CDML2 Select Data Matrix Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar cod...

Страница 194: ...axicode labels DEFAULT CMXEN00 CR Maxicode Disable CMXEN01 CR Maxicode Enable Maxicode Primary Message Transmission Enables disables the transmission of only the Primary Message when the Secondary Mes...

Страница 195: ...ntrol Length 1 is the minimum label length if in Variable Length Mode or the first fixed length if in Fixed Length Mode Characters can be set from 0001 to 0145 charac ters in increments of 0001 pad wi...

Страница 196: ...01 pad with zeros See page 241 for detailed instructions on setting this feature CMXL2 Select Maxicode Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above t...

Страница 197: ...PDF417 Enable DEFAULT PDF417 Length Control This feature specifies either variable length decoding or fixed length decod ing for this symbology Variable Length For variable length decoding a minimum a...

Страница 198: ...f 01 Any value greater than 2 710 will be considered to be 2 710 See page 241 for detailed instructions on setting this feature CP4L1 Select PDF417 Length 1 Setting To configure this feature scan the...

Страница 199: ...710 characters pad with zeros in increments of 01 Any value greater than 2 710 will be considered to be 2 710 See page 241 for detailed instructions on setting this feature CP4L2 Select PDF417 Length...

Страница 200: ...CR Micro PDF417 Enable Micro PDF417 Code 128 GS1 128 Emulation Specifies which AIM ID to use for MicroPDF labels when doing Code 128 or GS1 128 emulation Emulation choices are Micro PDF AIM ID and lab...

Страница 201: ...in Variable Length Mode or the first fixed length if in Fixed Length Mode Length includes the bar code s data charac ters only Characters can be set from 0001 to 0366 characters pad with zeros in incr...

Страница 202: ...nts of 01 Any value greater than 0366 will be considered to be 0366 See page 241 for detailed instructions on setting this feature CMIL2 Select Micro PDF417 Length 2 Setting To configure this feature...

Страница 203: ...QR Code Enable DEFAULT QR Code Length Control This feature specifies either variable length decoding or fixed length decod ing for this symbology Variable Length For variable length decoding a minimum...

Страница 204: ...with zeros See page 241 for detailed instructions on setting this feature CQRL1 Select QR Code Length 1 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the...

Страница 205: ...0001 pad with zeros See page 241 for detailed instructions on setting this feature CQRL2 Select QR Code Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above...

Страница 206: ...Micro QR Code Enable Micro QR Code Length Control This feature specifies either variable length decoding or fixed length decod ing for this symbology Variable Length For variable length decoding a min...

Страница 207: ...1 pad with zeros See page 241 for detailed instructions on setting this feature CMQL1 Select Micro QR Code Length 1 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code abo...

Страница 208: ...of 0001 pad with zeros See page 241 for detailed instructions on setting this feature CMQL2 Select QR Code Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code abo...

Страница 209: ...CC Composite Enable Disable Enables disables the ability of the reader to decode the stacked part of a UCC Composite label DEFAULT CCMEN00 CR UCC Composite Disable CCMEN01 CR UCC Composite Enable This...

Страница 210: ...omposite label before transmitting the linear label without an add on DEFAULT CCMOT00 CR UCC Optional Composite Timer Timer Disabled CCMOT01 CR UCC Optional Composite Timer 100msec CCMOT02 CR UCC Opti...

Страница 211: ...Codes Australia Post Postnet Japan Post Planet IMB Royal Mail Sweden Post Kix Portugal Post DEFAULT CPOEN00 CR Postal Code Selection Disable All Postal Codes CPOEN01 CR Postal Code Selection Enable P...

Страница 212: ...7 CR Postal Code Selection Enable IMB CPOEN08 CR Postal Code Selection Enable Sweden Post CPOEN09 CR Postal Code Selection Enable Portugal Post Postnet BB Control Controls the ability of the scanner t...

Страница 213: ...e restored 2 Using Datalogic Aladdin available on the Datalogic website or a Ter minal Emulation Program send the Restore Current Interface Custom Default string to the reader using the syntax describ...

Страница 214: ...mand Where Command Description HAXX Interface Selection AA Enable All Symbologies AD Disable All Symbologies R Reset Reader CXXXXXX Write Single Configuration Item to RAM Parameter XXXX A 4 character...

Страница 215: ...Mode 2 HA05 CR Select RS232 Interface 3 Ar CR Apply and Save Configuration to FLASH permanent memory and Exit Service Mode Example 3 1 CR Read Application Software Release Example 4 Some parameters e...

Страница 216: ...tware Release does not require Enter Exit Service Mode Host Commands Obey CIFIH00 Host Commands Ignore CIFIH01 Enable All Symbologies AA Disable All Symbologies AD The Interface Selection commands sto...

Страница 217: ...Stop Bits 1 R2ST 00 2 01 Handshaking Control RTS R2HC 00 RTS CTS R2HC 01 RTS Xon Xoff R2HC 02 RTS On CTS R2HC 03 RTS CTS Scan Control R2HC 04 To read a particular parameter setting from the reader se...

Страница 218: ...AK Error Handling Ignore errors detected R2EH 00 Process errors as valid ACK character 01 Process errors as valid NAK charac ter 02 Beep On ASCII BEL Disable R2BB 00 Enable 01 Beep On Not On File Disa...

Страница 219: ...ry 0D Italy 06 Japanese 106 key 0C Norway 07 Poland 12 Portugal 08 Romania 10 Slovakia 0F Spain 09 Sweden 0A Switzerland 0B Send Control Characters CTRL KEY KBSC 00 CTRL SHIFT KEY 01 Special Function...

Страница 220: ...Trigger Stop Timeout 02 Timeout Scan Active Time 1 to 255 seconds in 1 second intervals SNET h Serial Start Any string of characters max 20 between 00 FE STON i Serial Stop Any string of characters ma...

Страница 221: ...ax 20 between 00 FE LFPR k Global Suffix Terminator Any string of characters max 20 between 00 FE LFSU k No Read String Any string of characters max 20 between 00 FE NORS k Disable 00 Enable 01 Charac...

Страница 222: ...or EAN UPC w P5 G5ID k Code 39 C3ID k Code 32 P3ID k Code 128 C8ID k GS1 128 U8ID k ISBT 128 I8ID k Interleaved 2 of 5 I2ID k Standard 2 of 5 S2ID k Industrial 2 of 5 U2ID k Datalogic 2 of 5 D2ID k IA...

Страница 223: ...rom 10 to 2550 ms BPLE o Good Read Led Duration Time length from 0 to 25 500 ms LAGL f Green Spot Duration Disable LSSP 00 Short 300ms 01 Medium 500ms 02 Long 800ms 03 Led Indication On Decode BPIN 00...

Страница 224: ...coupon barcodes to be decoded CPCL 00 Enable only UPC A coupon decoding 01 Enable only GS1 Databar coupon decoding 02 UPC E UPC E Disable EBEN 00 Enable 01 Check Character Tx Disable EBCT 00 Enable 01...

Страница 225: ...r Tx Disable 8BCT 00 Enable 01 Expand to EAN 13 Disable 8B3B 00 Enable 01 Minimum Reads One Read 8BMR 01 Two Reads 02 Three Reads 03 Four Reads 04 Add Ons P2 Add On Disable ADO2 00 Enable 01 P5 Add On...

Страница 226: ...sable C3FA 00 Enable 01 Code Length Control Variable C3LC 00 Fixed 01 Set Length Length 1 or Min Length from 1 to 50 characters C3L1 q Length 2 or Max Length 0 or from 1 to 50 charac ters C3L2 q Code...

Страница 227: ...des 02 Auto 03 Virtual Quiet Zones on Two Sides 04 Small Quiet Zones on Two Sides 05 Stitching Disable C3ST 00 Enable 01 Code 128 GS1 128 Code 128 Disable C8EN 00 Enable 01 GS1 128 Enable Enable trans...

Страница 228: ...l 1 01 Level 2 02 Level 3 03 Level 4 04 Level 5 05 Character Correlation Disable C8CO 00 Enable 01 Quiet Zones No Quiet Zones C8LO 00 Quiet Zone on One Side 01 Quiet Zones on Two Sides 02 Auto 03 Virt...

Страница 229: ...C 00 Enable Standard Mod 10 01 Enable German Parcel 02 Enable DHL 04 Enable Daimler Chrysler 08 Enable Bosch 10 Enable Italian Post 20 Check Tx Disable I2CT 00 Enable 01 Decoding Options Minimum Reads...

Страница 230: ...MR 01 Two Reads 02 Three Reads 03 Four Reads 04 Decoding Level Disable S2DL 00 Level 1 01 Level 2 02 Level 3 03 Level 4 04 Level 5 05 Character Correlation Disable S2CO 00 Enable 01 Stitching Disable...

Страница 231: ...gic 2 of 5 Disable D2EN 00 Enable 01 Code Length Control Variable D2LC 00 Fixed 01 Set Length Length 1 or Min Length from 1 to 50 characters D2L1 v Length 2 or Max Length 0 or from 1 to 50 charac ters...

Страница 232: ...1 Concatenation Mode Static CBCM 00 Dynamic 01 Dynamic Concat Timeout From 50 to 2550 ms CBDT t Check Options Check Calculation Disable CBCC 00 Enable AIM Standard Check 01 Enable Mod 10 Check 02 Chec...

Страница 233: ...es on Two Sides 05 Stitching Disable CBST 00 Enable 01 GS1 Databar Omnidirectional GS1 Databar Omnidirec tional Disable 4BEN 00 Enable 01 GS1 128 Emulation Disable 4BU8 00 Enable 01 Omnidirectional De...

Страница 234: ...tion Disable LBU8 00 Enable 01 Limited Decoding Options Minimum Reads One Read LBMR 01 Two Reads 02 Three Reads 03 Four Reads 04 Code 93 Code 93 Disable C9EN 00 Enable 01 Code Length Control Variable...

Страница 235: ...hing Disable C9ST 00 Enable 01 MSI MSI Disable MSEN 00 Enable 01 Code Length Control Variable MSLC 00 Fixed 01 Set Length Length 1 or Min Length from 1 to 50 characters MSL1 v Length 2 or Max Length 0...

Страница 236: ...or from 1 to 50 charac ters PLL2 v Check Options Check Calculation Disable PLCC 00 Standard 01 Anker Calculation 02 Standard and Anker Calculation 03 Check Tx Disable PLCT 00 Enable 01 Decoding Option...

Страница 237: ...Length Control Variable AZLC 00 Fixed 01 Set Length Length1 Min for Variable 1 AZL1 q Length2 Max for Variable 3832 AZL2 q China Sensible Code China Sensible Code Disabled CSEN 00 Enabled 01 Code Len...

Страница 238: ...0 Enabled 01 Code Length Control Variable P4LC 00 Fixed 01 Set Length Length1 Min for Variable 1 P4L1 v Length2 Max for Variable 2710 P4L2 v Micro PDF417 Micro PDF417 Disabled MIEN 00 Enabled 01 Code...

Страница 239: ...d 01 Code Length Control Variable MQLC 00 Fixed 01 Set Length Length1 Min for Variable 1 MQL1 y Length2 Max for Variable 35 MQL2 y UCC Composite UCC Composite Disabled CMEN 00 Enabled 01 Optional Comp...

Страница 240: ...Software Configuration Strings 230 Gryphon GPS4400 NOTES...

Страница 241: ...SB Intercode Delay on page 240 SYMBOLOGIES on page 241 Set Length on page 241 DATA EDITING on page 243 Global Prefix Suffix on page 244 Global AIM ID on page 245 Label ID on page 246 Character Convers...

Страница 242: ...he parity type according to host device requirements Select None when no parity bit is required Select Odd parity and the parity bit value is set to 0 or 1 based on data to ensure that an odd number o...

Страница 243: ...LECT INTERCHARACTER DELAY SETTING 5 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep in...

Страница 244: ...on of these characters 8 bit data is not recognized when the option Data Bits has been set as 7 Data Bits 1 Determine the desired character or value 2 Use the ASCII Chart on the inside back cover of t...

Страница 245: ...r value 3 Go to page 25 and scan the ENTER EXIT PROGRAMMING MODE bar code to enter Programming Mode 4 Scan the bar code SELECT NAK CHARACTER SETTING 5 Scan the appropriate two alphanumeric characters...

Страница 246: ...AK TIMEOUT VALUE SETTING 5 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication...

Страница 247: ...igits from the keypad in Appendix D Keypad that represent the number which was determined in the steps above You will hear a two beep indication after the last character If you make a mistake before t...

Страница 248: ...character value 3 Go to page 28 and scan the ENTER EXIT PROGRAMMING MODE bar code to enter Programming Mode 4 Scan the bar code SELECT DISABLE CHARACTER SETTING 5 Scan the appropriate two alphanumeric...

Страница 249: ...uivalent for the desired character value 3 Go to page 28 and scan the ENTER EXIT PROGRAMMING MODE bar code to enter Programming Mode 4 Scan the bar code SELECT ENABLE CHARACTER SETTING 5 Scan the appr...

Страница 250: ...ppendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character If you make a mistake before the last character scan t...

Страница 251: ...its For exam ple 0 00 5 05 20 20 etc 2 Go to the Set Length page for your selected symbology and scan the ENTER EXIT PROGRAMMING MODE bar code to enter Programming Mode 3 Scan the bar code to SELECT L...

Страница 252: ...o enter Programming Mode 3 Scan the bar code to SELECT LENGTH 2 SETTING for your selected sym bology 4 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the length se...

Страница 253: ...scanned symbology AIM ID This function is used to identify and display the common label identifier for its symbology When enabled this ID code will be transmitted before the scanned bar code data OR...

Страница 254: ...the ENTER EXIT PROGRAMMING MODE bar code then scan the SET GLOBAL PREFIX bar code 3 Reference the ASCII Chart on the inside back cover of this manual to find the hex value assigned to the desired char...

Страница 255: ...llows A close brace character ASCII followed by A code character see the table below followed by A modifier character the modifier character is symbol dependent SYMBOLOGY CHAR SYMBOLOGY CHAR UPC EAN E...

Страница 256: ...d Sets The reader supports two pre loaded sets of Label IDs Table 33 shows the USA and the EU sets CAUTION When changing from one Label ID set to another all other reader con figuration settings inclu...

Страница 257: ...C0000 EAN13 P5 F 460000 M 4D0000 EAN13 COMPOSITE F 460000 F 244600 EAN8 FF 464600 A 410000 EAN8 P2 FF 464600 J 4A0000 EAN8 P5 FF 464600 K 4B0000 EAN8 COMPOSITE FF 464600 G 244700 FOLLET 2OF5 O 4F0000...

Страница 258: ...000 POSTAL POSTNET BB L 244C00 L 244C00 POSTAL ROYAL MAIL M 244D00 M 244D00 POSTAL SWEDISH X 245800 X 245800 POSTNET 1 310000 1 310000 QR CODE QR 515200 y 790000 S25 s 730000 P 500000 TRIOPTIC T 24540...

Страница 259: ...ill represent the Label ID for the selected symbology 5 Turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID For e...

Страница 260: ...g on page 50 DataBar Omnidirectional Code 39 Interleaved 2 of 5 Code 32 4 Custom Label ID example desired characters D B C 3 P H 5 Find hex equivalents from the ASCII Chart insideback cover then scan...

Страница 261: ...label AB12BA21 it would look as follows after the character con version BB22BB22 The A characters were converted to B characters and the 1 characters were converted to 2 characters Nothing is done wi...

Страница 262: ...R EXIT PROGRAMMING MODE barcode once again to exit Programming Mode Code Verifier Code Verifier is available in On Line or Serial On Line and Automatic modes only A programmable character or string is...

Страница 263: ...erminate the string 7 Scan the ENTER EXIT PROGRAMMING MODE barcode to complete Wrong Code String The string sent in case of a mismatch wrong code read To set this feature 1 Determine the desired chara...

Страница 264: ...e to enter Programming Mode 4 Scan the bar code SET DOUBLE READ TIMEOUT SETTING 5 Scan the appropriate three alphanumeric characters from the keypad in Appendix D Keypad representing the duration whic...

Страница 265: ...he bar code SELECT GOOD READ LED DURATION SETTING 5 Scan the appropriate three digits from the keypad in Appendix D Keypad representing the duration which was determined in the steps above You will he...

Страница 266: ...the reading phase ends when the first event occured Timeout Specifies the maximum duration for the reading phase Selections from 1 to 255 seconds in 1 second increments Serial On Line In Serial On Li...

Страница 267: ...ing zone and is decoded no more decodes and reading phases are allowed until the label has left the reading area In order to guar antee identification of the code in the reading zone a threshold speci...

Страница 268: ...e appropriate three digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character If you...

Страница 269: ...m the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character If you make a mistake before the last...

Страница 270: ...bolo gies 3 Go to page 78 and scan the ENTER EXIT PROGRAMMING MODE bar code to enter Programming Mode 4 Scan the bar code SELECT SYMBOLOGIES FOR MULTIPLE LABELS ORDERING 5 Scan the appropriate two alp...

Страница 271: ...C 11 Reserved 3B LABELIMAGE 12 Reserved 3C CAPTURE_IMAGE_LABEL 13 CODE49 3D Reserved 14 UPC E2 3E M2OF5 15 UPC E5 3F D2OF5 16 Reserved 40 PLESSEY65 17 UPC A2 42 ISSN 18 UPC A5 43 ISBT 19 Reserved 44 R...

Страница 272: ...References Scanning Features 262 Gryphon GPS4400 NOTES...

Страница 273: ...ry information Table 41 Technical Specifications ITEM DESCRIPTION Physical Characteristics Color White Gray Black Gray Dimensions Without Stand Height 74 Length 95 Width 64 With Stand Height 121 Lengt...

Страница 274: ...ield Typical NF Near Field FF Far Field cm inches NF FF NF FF Code 39 4mil Code 39 5mil Code 39 10mil Code 39 20mil 4 2 2 6 0 0 0 0 15 4 18 8 37 9 57 1 1 7 1 0 0 0 0 0 6 0 7 4 14 9 22 5 EAN 7 5mil EAN...

Страница 275: ...stal Codes Australian Post Japanese Post KIX Post Planet Code Postnet Royal Mail Code RM45CC Intelligent Mail Barcode IMB Sweden Post Portugal Post LaPoste A R 39 4 State Canada PDF 417 MacroPDF Micro...

Страница 276: ...nctions The following tables list these indications One exception to the behaviors listed in the tables is that the reader s functions are pro grammable and so may or may not be turned on For example...

Страница 277: ...A Reader sounds one high frequency beep and 4 low frequency beeps followed by reset beeps Label Programming Mode Cancel Item Entry Cancel label has been scanned N A Reader sounds two times at low fre...

Страница 278: ...s Error Corrective Action 1 Configuration Contact Helpdesk for assistance 2 Interface PCB 6 Digital PCB 11 Imager Host Interface Connections The reader auto detects if a USB host cable is attached at...

Страница 279: ...Technical Specifications Product Reference Guide 269 GPS4400 Dimensions Figure 7 GPS4400 Without Stand Dimensions in mm...

Страница 280: ...Technical Specifications 270 Gryphon GPS4400 Figure 8 GPS4400 Dimensions With Stand Dimensions in mm...

Страница 281: ...ails as they may vary Bottom of Stand This product complies with 21CFR 1040 10 and 1040 11 except for deviations pursuant to Laser Notice No 50 dated June 24 2007 See Pkg for patent listing LASERLIGHT...

Страница 282: ...Technical Specifications 272 Gryphon GPS4400 NOTES...

Страница 283: ...able features This section shows standard defaults If your reader was provided with a custom configuration your defaults may differ from those shown Table 42 Standard Defaults Parameter Default Your S...

Страница 284: ...d Speed 1 ms 36 USB Keyboard Numeric Keypad Standard Keys 37 USB OEM USB OEM Device Usage Handheld 40 Transmit Labels in Code 39 Format IBM Standard Format 41 Interface Options Ignore Scanner Configu...

Страница 285: ...d Beep Volume High 66 Good Read LED Duration 300 ms 67 Scanning Features Operating Mode On Line 68 Phase Off Event Trigger Stop 69 Phase Off Timeout 5 Timeout set for 5 seconds 69 Serial Start Charact...

Страница 286: ...UPCA coupon decoding 81 UPC A UPC A Enable Disable Enable 82 UPC A Check Character Transmission Send 82 Expand UPC A to EAN 13 Don t Expand 83 UPC A Number System Character Trans mission Transmit 83 U...

Страница 287: ...EAN 8 2D Component 2D Component Not Required 92 UPC EAN Global Settings UPC EAN Price Weight Check Disable 93 UPC EAN Quiet Zones Two Modules 94 Add Ons Optional Add ons Disable P2 P5 and P8 95 Option...

Страница 288: ...pecial Codes Code 39 Danish PPT Enable Disable Disable 110 Code 39 LaPoste Enable Disable Disable 111 Code 39 PZN Enable Disable Disable 111 Code 128 Code 128 Enable Disable Enable 112 Expand Code 128...

Страница 289: ...I 2 of 5 Set Length 1 6 125 I 2 of 5 Set Length 2 50 126 Interleaved 2 of 5 CIP HR Interleaved 2 of 5 CIP HR Enable Disable Disable 127 Follett 2 of 5 Follett 2 of 5 Enable Disable Disable 127 Standar...

Страница 290: ...Character Transmis sion Transmit 138 Codabar Start Stop Character Set abcd abcd 139 Codabar Start Stop Character Match Don t Require Match 139 Codabar Quiet Zones Small Quiet Zones on two sides 140 C...

Страница 291: ...e 152 GS1 DataBar Expanded 2D Component 2D component not required 152 GS1 DataBar Expanded Length Control Variable 153 GS1 DataBar Expanded Set Length 1 1 154 GS1 DataBar Expanded Set Length 2 74 155...

Страница 292: ...ssion Enable 163 MSI Length Control Variable 165 MSI Set Length 1 1 165 MSI Set Length 2 50 166 Plessey Plessey Enable Disable Disable 167 Plessey Check Character Calculation Enable Plessey std check...

Страница 293: ...e Disable 178 China Sensible Code Length Control Variable 178 China Sensible Code Set Length 1 1 179 China Sensible Code Set Length 2 7 827 180 Data Matrix Data Matrix Enable Disable Enable 181 Data M...

Страница 294: ...F417 Set Length 2 0366 192 QR Code QR Code Enable Disable Enable 193 QR Code Length Control Variable 193 QR Code Set Length 1 1 194 QR Code Set Length 2 7 089 195 Micro QR Code Micro QR Code Enable Di...

Страница 295: ...ct Reference Guide 285 Appendix C Sample Bar Codes The sample bar codes in this appendix are typical representations for their symbology types 1D Bar Codes UPC A EAN 13 Code 39 Code 128 Interleaved 2...

Страница 296: ...Sample Bar Codes 286 Gryphon GPS4400 1D Bar Codes continued Code 32 Codabar Code 93 Code 11...

Страница 297: ...d GS1 DataBar Limited GS1 DataBar Truncated GS1 DataBar Stacked 01 12345678901231 GS1 DataBar Omnidirectional Stacked 01 12345678901231 GS1 DataBar Expanded Stacked 0123456789012313 GS1 DataBar varian...

Страница 298: ...00 2D Bar Codes Aztec ABCabc Datamatrix ABCabc China Sensible Code 12345678 MaxiCode ABCabc PDF 417 ABCabc Micro PDF 417 12345678 QR Code ABCabc Micro QR Code ABCDEF DataBar Expanded Stacked Composite...

Страница 299: ...Product Reference Guide 289 Appendix D Keypad Use the bar codes in this appendix to enter numbers as you would select digits characters from a keypad 0 1 2 3 4 5 6 7 8 9...

Страница 300: ...Keypad 290 Gryphon GPS4400 A B C D E F...

Страница 301: ...Hex Value Notes SOH 0x01 BEL 0x07 0x23 0x24 0 0x30 3 0x33 B 0X42 D 0X44 E 0X45 F 0X46 R 0X52 S 0X53 h 0x68 i 0x69 s 0x73 t 0x74 FF 0xFF Reserved Strings C up to 36 chars CR 0x43 xxx 0x0D C can be use...

Страница 302: ...292 Gryphon GPS4400 NOTES...

Страница 303: ...er Ctrl Capital Key special keys are located from 0x80 to 0xA1 Control Character 02 Special keys are located from 00 to 0x1F and characters from 0x80 to 0xFE are intended as an extended ASCII table Mi...

Страница 304: ...DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C GS C RS C US C S _ 2x SP 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q...

Страница 305: ...02 x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keypd Enter Ins Pg Up 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9...

Страница 306: ...A 092 A 093 A 094 A 095 6x A 096 A 097 A 098 A 099 A 100 A 101 A 102 A 103 A 104 A 105 A 106 A 107 A 108 A 109 A 110 A 111 7x A 112 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122 A 123 A...

Страница 307: ...112 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122 A 123 A 124 A 125 A 126 A 127 8x A 0128 A 0129 A 0130 A 0131 A 0132 A 0133 A 0134 A 0135 A 0136 A 0137 A 0138 A 0139 A 0140 A 0141 A 01...

Страница 308: ...c FS C S GS C RS C S US C S _ 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a b c d e f g h i j k l m n o 7x p q r s t u v w x y z Del 8x Sh Sh Ins Ent...

Страница 309: ...3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a B c d e f g h i j k l m n o 7x p q R s t u v w x y z Del 8x Sh Sh Ins Ent keyp F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 9x F12...

Страница 310: ...Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a B c d e f g h i j k l m n o 7x p q R s t u v w x y z Del 8x Sh Sh Ins Ent keyp F1 F2 F3 F4 F5 F6 F7 F8 F9...

Страница 311: ...rence Guide 301 Microsoft Windows Codepage 1252 Windows 1252 is a character encoding of the Latin alphabet used by default in the legacy components of Microsoft Windows in English and some other Weste...

Страница 312: ...302 Gryphon I GPS4400 NOTES...

Страница 313: ...Product Reference Guide 303 Appendix G Screw Mounting Template If desired scan or detach this page to use as a template for mounting Shown actual size...

Страница 314: ...304 Gryphon GPS4400 NOTES...

Страница 315: ...14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP 0 1 2 3 4 5 6 7 8 9 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F A B C D E F G H I J K L M N O P Q R S T U V...

Страница 316: ...phone 1 541 683 5700 Fax 1 541 345 7140 2013 Datalogic ADC Inc All rights reserved Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A a...

Отзывы: