ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
253
CODE 4
The following options apply to the Code 4 symbology.
Code 4 Enable/Disable
Enables/Disables ability of imager to decode Code 4 labels.
DEFAULT
Code 4 = Disable
Code 4 = Enable
Code 4 Check Character Transmission
This feature enables/disables transmission of an optional Code 4 check charac-
ter.
Code 4 Check Character Transmission = Don’t Send
Code 4 Check Character Transmission = Send
DEFAULT