background image

Gryphon™ I GD4200

QUICK REFERENCE GUIDE

General Purpose Corded

Handheld Linear Bar Code Reader

Содержание Gryphon GD4200

Страница 1: ...Gryphon I GD4200 QUICK REFERENCE GUIDE General Purpose Corded Handheld Linear Bar Code Reader ...

Страница 2: ...ay be downloaded from the Data logic website www datalogic com If you visit our website and would like to make comments or suggestions about this or other Datalogic publica tions please let us know via the Contact page Disclaimer Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate however Datalogic shall not be liable for technical or editori...

Страница 3: ... and Location of Green Spot 5 Parts of the Reader 6 Selecting the Interface Type 6 Interface Selection 6 Configuring the Interface 7 USB Interface 8 Keyboard Wedge Interface 10 Country Mode 12 Programming 16 Using Programming Bar Codes 16 Configure Other Settings 16 Resetting Product Defaults 16 Numlock 17 Caps Lock State 18 Reading Parameters 19 Good Read Green Spot Duration 19 Operating Modes 21...

Страница 4: ...Contents IV GRYPHON I GD4200 Cleaning Procedure 31 Common Cleaning Solutions 31 Cleaning enclosure and window surfaces 32 ...

Страница 5: ...rt re export resell ship or divert or cause to be exported re exported resold shipped or diverted directly or indirectly the Soft ware under this Agreement End User shall not and shall not permit others to i modify translate decompile reverse engineer disas semble or extract the inner workings of the Software ii copy the functionality of the Datalogic Products iii remove any proprietary notices ma...

Страница 6: ... the Software will immediately terminate and End User must immediately stop using the Software destroy all copies of the Software and all of its component parts and upon request provide an affidavit certifying your compliance with the foregoing The provisions of Sub sections 1 2 1 3 1 4 1 5 4 5 6 8 and 11 shall survive termination of this Agreement 4 Limited Warranty Datalogic warrants that under ...

Страница 7: ...rd support fees and under Datalogic s standard support terms and conditions in effect at the time the support is requested 8 Government Restricted Rights International Use 8 1 Use duplication or disclosure of the Software by the U S Govern ment is subject to the restrictions for computer software developed at private expense as set forth in the U S Federal Acquisition Regula tions at FAR 52 227 14...

Страница 8: ... Nations Convention on Contracts for the International Sale of Goods does not apply All rights duties and obligations are subject to the courts of the country in which End User obtained the license For licenses granted by Licensee who operates in the countries specified below the following terms apply For Americas This Agreement is governed by the laws of the State of Oregon This Agree ment and th...

Страница 9: ...es in the post of chairman will be filled by the president of the SIAC Other vacancies will be filled by the respective nominating party Proceedings will continue from the stage they were at when the vacancy occurred If one of the parties refuses or otherwise fails to appoint an arbitrator within 30 days of the date the other party appoints its the first appointed arbitrator will be the sole arbit...

Страница 10: ...EULA X GRYPHON I GD4200 NOTES ...

Страница 11: ...nd manufactur ing plants Top Productivity for POS and Document Handling Perfect for manual reading the Gryphon GD4200 linear imager uses Datalogic s Motionix motion detection technology that detects the operator s natural actions to automatically switch the scanner into ready to read scan mode The distinctive soft line viewfinder of Datalogic helps the operator to easily identify the code to be re...

Страница 12: ...cessory is available which holds the reader at a con venient angle allowing hands free scanning of items It can also be used as a holder The reader automatically rec ognizes the insertion and changes its Scan Mode to allow the user to operate in hands free mode ...

Страница 13: ...ps below to connect and get your reader up and communicating with its host 1 Connect the Cable to the reader and the Host as shown below 2 Configure the Interface see page 7 3 Program the Reader starting on page 16 optional as needed Connecting to the Host Interface USB WEDGE RS 232 ...

Страница 14: ...cable make sure the connector clip is on the same side as the reader release hole Insert the cable it should click when it is fully inserted USING THE GRYPHON I GD4200 The Gryphon I GD4200 normally functions by capturing and decoding codes The reader is equipped with an inter nal Motionix motion sensing function which activates the aiming system on device motion The intelligent aim ing system indi...

Страница 15: ...bars or ele ments mil size should be read closer to the unit Symbologies with larger bars or elements mil size should be read farther from the unit If the aiming system is cen tered and the entire bar code is within the aiming field you will get a good read Successful reading is signaled by an audible tone plus a good read green spot LED indicator Refer to the Gryphon I GD4200 Product Reference Gu...

Страница 16: ...this manual see the Gryphon I GD4200 Product Reference Guide PRG available online at www datalogic com Interface Selection The reader will support all the following host interfaces RS 232 STD RS 232 WN IBM46XX port 9b a specific cable s required USB HID POS USB Toshiba TEC USB Keyboard COM OEM USB Composite Keyboard COM USB for Magellan Scanners Keyboard Wedge Information and programming options f...

Страница 17: ...l DO NOT scan an ENTER EXIT bar code prior to scan ning an interface selection bar code Some interfaces require the scanner to start in the disabled state when powered up If additional scanner configuration is desired while in this state pull the trigger and hold for 5 seconds The scanner will change to a state that allows pro gramming with bar codes RS 232 RS 232 standard interface Select RS232 S...

Страница 18: ...dditional power supply is required When using a USB interface the reader auto detects the USB cable and defaults to the USB keyboard interface IBM IBM 46xx Port 5B reader interface Select IBM P5B IBM 46xx Port 9B reader interface Select IBM P9B USB Select USB Keyboard with standard key encoding Select USB COM STD simulates RS 232 standard interface ...

Страница 19: ...Configuring the Interface QUICK REFERENCE GUIDE 9 USB CONTINUED Select USB Alternate Keyboard with alternate key encoding Select USB OEM Select USB KBD APPLE for Apple computers ...

Страница 20: ... type KEYBOARD Select KBD AT AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Standard Key Encoding Select KBD AT NK IBM AT PS2 with standard key encoding but without external kbd Select KBD AT ALT AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Alternate Key Select KBD AT ALT NK for IBM AT PS2 with alternate key encoding but without external keyboard ...

Страница 21: ...XT PC XT w Standard Key Encoding Select KBD IBM 3153 for IBM Terminal 3153 Select KBD IBM M for IBM Terminals 31xx 32xx 34xx 37xx make only keyboard Select KBD IBM MB for IBM Terminals 31xx 32xx 34xx 37xx make break keyboard Select KBD DIG VT for DIGITAL Terminals VT2xx VT3xx VT4xx ...

Страница 22: ...Std Key Encoding Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 without Alternate Key Keyboard Wedge for IBM AT PS2 without alternate key encoding but without external keyboard All other interfaces support ONLY the following Country Modes U S Belgium Britain France Germany Italy Spain Sweden COUNTRY MODE ENTER EXIT...

Страница 23: ...IDE 13 COUNTRY MODE CONTINUED Country Mode Croatia Country Mode Czech Republic Country Mode Denmark Country Mode France Country Mode French Canadian Country Mode Germany Supports only the interfaces listed in the Country Mode feature description ...

Страница 24: ... GD4200 COUNTRY MODE CONTINUED Country Mode Hungary Country Mode Italy Country Mode Japanese 106 key Country Mode Lithuanian Country Mode Norway Country Mode Poland Supports only the interfaces listed in the Country Mode feature description ...

Страница 25: ...NCE GUIDE 15 COUNTRY MODE CONTINUED Country Mode Portugal Country Mode Romania Country Mode Slovakia Country Mode Spain Country Mode Sweden Country Mode Switzerland Supports only the interfaces listed in the Country Mode feature description ...

Страница 26: ...code once to enter Programming Mode scan the desired parameter settings scan the ENTER EXIT bar code again to accept your changes which exits Programming Mode and returns the reader to normal operation Configure Other Settings Additional programming bar codes are available in the PRG to allow for customizing programming features If your installation requires different programming than the standard...

Страница 27: ...etting of the Numbers Lock Numlock key while in keyboard wedge interface This only applies to alternate key encoding interfaces It does not apply to USB keyboard NUMLOCK ENTER EXIT PROGRAMMING MODE Numlock Numlock key unchanged Numlock Numlock key toggled default value ...

Страница 28: ... the format in which the reader sends character data This applies to keyboard wedge interfaces This does not apply when an alternate key encoding key board is selected CAPS LOCK STATE ENTER EXIT PROGRAMMING MODE Caps Lock OFF Caps Lock ON AUTO Caps Lock Enable default value ...

Страница 29: ...uisi tion time and if no code is decoded will switch on again before the next acquisition The illuminator will remain on until the symbol is decoded As you read code symbols adjust the distance at which you are holding the reader GOOD READ GREEN SPOT DURATION Successful reading can be signaled by a good read green spot Use the bar codes that follow to specify the duration of the good read pointer ...

Страница 30: ...Good Read Green Spot Duration 20 GRYPHON I GD4200 GREEN SPOT DURATION CONTINUED Medium 500 ms Long 800 ms default value ...

Страница 31: ...gger Hold Multiple When the trigger is pulled scan ning starts and the product scans until the trigger is released or maximum scan on time 1 has elapsed Read ing a label does not disable scanning Double Read Time out1 prevents undesired multiple reads while in this mode Always On The illuminator is always ON and the reader is always ready for code reading Double Read Timeout1 prevents undesired mu...

Страница 32: ...Operating Modes 22 GRYPHON I GD4200 SCAN MODE ENTER EXIT PROGRAMMING MODE Trigger Single Trigger Pulse Multiple Trigger Hold Multiple default value ...

Страница 33: ...Operating Modes QUICK REFERENCE GUIDE 23 SCAN MODE CONTINUED Flashing Always ON Stand Mode ...

Страница 34: ... oz ELECTRICAL CHARACTERISTICS Power Supply GD4220 5VDC 5 GD4290 4 5 14 0 VDC Consumption Operating Typical 350mA 5V 150mA 12V Standby Idle Typical 60mA 5V 30mA 12V Max Scan Rate 400 reads sec Reading Indicators Top and rear illumination Good Read Spot Beep ENVIRONMENTAL CHARACTERISTICS Operating Tem perature 0 C to 50 C 32 F to 122 F Storage Tempera ture 40 C to 70 C 40 F to 158 F Humidity 95 non...

Страница 35: ...C EAN JAN A E 13 8 UPC EAN JAN including P2 P5 UPC EAN JAN including ISBN Bookland ISSN UPC EAN Coupons Code 39 including full ASCII Code 39 Trioptic Code39 CIP French Pharmaceutical LOGMARS Code 39 w standard check digit enabled Danish PPT Code 32 Italian Pharmacode 39 Code 128 Code 128 ISBT Interleaved 2 of 5 Standard 2 of 5 Interleaved 2 of 5 CIP HR Industrial 2 of 5 Discrete 2 of 5 Datalogic 2...

Страница 36: ...ance than longer bar codes as explained in the image below Code 39 5mils 50 to 370mm 1 97 to 14 6 inchb b All labels grade A typical environmental light 20 C label inclination 10 Code 39 7 5mils 50 to 540mm 1 97 to 21 3 inchb Code 39 10mils 50 to 735mm 1 97 to 28 9inchb Code 39 20mils 25 to 1470mm 0 98 to 57 87 inchb EAN13 13 mils 35 to 900mm 1 38 to 35 43 inchb Resolution Maximum 0 0077mm 3mils ...

Страница 37: ...the LED blinks until enumeration with the host is completed Reader beeps four times at highest frequency and volume upon power up Good Read Upper green LED comes on for programmed time default LED behavior for this indication is configurable using Aladdin utility One beep at current frequency volume mono bi tonal setting upon a successful label scan It is also possible to upload custom jingles wit...

Страница 38: ...eader not programmed for correct bar code type Ensure reader is programmed to read the type of bar code scanned Refer to the PRG for more information Bar code label is unreadable Check the label to ensure it is not defaced Try scanning another bar code type Distance between reader and bar code is incorrect Move reader closer to or further from the bar code Bar code is decoded but not transmitted t...

Страница 39: ... whole unit consumable items 7 use of counterfeit or replacement parts that are neither manu factured nor approved by Datalogic for use in Datalogic manufactured Products 8 any damage or malfunctioning caused by non restoring action as for example firmware or software upgrades software or hardware reconfigurations etc 9 loss of data 10 any consumable or equivalent e g cables power supply batteries...

Страница 40: ...om For quick access from the home page click on the search icon and type in the name of the product you re look ing for This allows you access to download Data Sheets Manuals Software Utilities and Drawings Hover over the Support Service menu for access to Ser vices and Technical Support Reseller Technical Support An excellent source for technical assistance and informa tion is an authorized Datal...

Страница 41: ...cleaning CAUTION DO NOT use abrasive pads or cleaning agents PRODUCT CHEMICAL CONTENT Sani Cloth HB Sani Cloth Plus Super Sani Cloth Quaternary Ammonium Chloride solution Hepacide Quat II Virucidal disinfectant cleaner Alcohol Wipes 70 Isopropyl Alcohol CaviWipes lsopropanol 10 20 Ethylene Glycol Monobutyl Ether 1 5 Virex 256 n Alkyl Dimethyl Benzyl Ammonium Chloride Didecyl Dimethyl Ammonium Chlo...

Страница 42: ...ace of the unit Use cotton swabs lightly moistened to reach in corners and crevices 3 Use another clean dry cloth to remove any residue of the cleaning agent and ensure the unit is dry NOTE Standard product enclosures are resistant to harsh chemical cleaning CAUTION DO NOT spray or pour cleaner directly onto the unit DO NOT use solutions in their concentrated form DO NOT use aerosols solvents or a...

Страница 43: ......

Страница 44: ...ted in any form or by any means or for any purpose without the express written permission of Datalogic S p A and or its affiliates Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries includ ing the U S and the E U Datalogic S r l Via S Vitalino 13 40012 Calderara di Reno Bologna Italy Tel 39 051 3147011 Fax 39 051 3147205 www datalogic com 820116801 Rev ...

Отзывы: