background image

Replacing the Battery Pack

QUICK REFERENCE GUIDE   

39

REPLACING THE BATTERY PACK

Use the following procedure to change the reader’s bat-
tery:

1. With a screwdriver, unscrew the battery cover screw.

2. Carefully remove the battery cable out of its connec-

tor and extract the battery pack from its slot.

NOTE: Before proceeding, read "

Battery Safety" on

page 41

. To ensure maximum performance, Data-

logic recommends the replacement of the
rechargeable battery pack if you note either of the
following conditions:

battery life drops below approximately 80%
of the original life;

battery charging time increases significantly.

Содержание Gryphon GBT4200

Страница 1: ...Gryphon I GBT GM4200 QUICK REFERENCE GUIDE General Purpose Handheld Bar Code Reader with Bluetooth Wireless Technology or Datalogic s STAR Cordless System...

Страница 2: ...may be downloaded from the Data logic website www datalogic com If you visit our website and would like to make comments or suggestions about this or other Datalogic publica tions please let us know...

Страница 3: ...canner LEDs 8 The WLC4190 Radio Base 9 Radio Base LEDs 9 Using the Gryphon I GBT GM4200 10 Aiming System 10 Relative Size and Location of Aiming Pattern 10 Linear Bar 10 Relative Size and Location of...

Страница 4: ...echnical Specifications 30 LED and Beeper Indications 33 Troubleshooting 34 Warranty 35 Ergonomic Recommendations 36 Technical Support 36 Support Through the Website 36 Reseller Technical Support 36 C...

Страница 5: ...xport re export resell ship or divert or cause to be exported re exported resold shipped or diverted directly or indirectly the Soft ware under this Agreement End User shall not and shall not permit o...

Страница 6: ...e the Software will immediately terminate and End User must immediately stop using the Software destroy all copies of the Software and all of its component parts and upon request provide an affidavit...

Страница 7: ...d support fees and under Datalogic s standard support terms and conditions in effect at the time the support is requested 8 Government Restricted Rights International Use 8 1 Use duplication or disclo...

Страница 8: ...d Nations Convention on Contracts for the International Sale of Goods does not apply All rights duties and obligations are subject to the courts of the country in which End User obtained the license F...

Страница 9: ...s in the post of chairman will be filled by the president of the SIAC Other vacancies will be filled by the respective nominating party Proceedings will continue from the stage they were at when the v...

Страница 10: ...EULA X GRYPHON I GBT GM4200 NOTES...

Страница 11: ...le devices make these readers the perfect choice for today s and tomorrow s applications in retail and office environments pharmacies light industrial warehouses and manufactur ing plants Top Producti...

Страница 12: ...settings needed NOTE According to recent modification of Regula tion for shipping Li Ion based battery packs the products and their spare battery packs parts are shipped with a very low residual char...

Страница 13: ...ical position in order to provide the most comfortable use depending on the needs Figure 1 Horizontal Position This position is preferred unless a different specific posi tioning is required for its o...

Страница 14: ...ESCRIPTION LEDs on the gun provide information about the battery charging status as well as data transmission Figure 3 Gryphon Base LEDs 1 Scan Window 2 Trigger 3 Battery Recharge LED 4 Good Read LED...

Страница 15: ...Connection and Routing Fully insert the Interface I F Cable connector into its port in the under side of the Base Station Figure 4 Connecting the Base Station NOTE When powered by the Terminal the bat...

Страница 16: ...he Base Station as shown in Figure 5 Figure 5 Options for routing the DC cord Host Connection Verify before connection that the reader s cable type is compatible with your host equipment Most connecti...

Страница 17: ...le Reader Layout Figure 8 Multiple Reader Layout In stand alone systems each cradle is connected to a sin gle Host Figure 9 Multiple Stand Alone Layout Many stand alone connections can operate in the...

Страница 18: ...good reading result 3GL and battery status The Battery Status information can be easily retrieved by double tapping with your fingers on top of the head of the scanner The following table lists the ba...

Страница 19: ...used to force device connection via the Datalogic Aladdin Software tool and for paging the scanner when it is activated Refer to the Gry phon I GBT GM4200 Product Reference Guide PRG for a more detai...

Страница 20: ...uld be positioned over the bar code Aiming System Relative Size and Location of Aiming Pattern Linear Bar A red beam illuminates the label The field of view indi cated by the aiming system will be sma...

Страница 21: ...d read Successful reading is signaled by an audible tone plus a good read green spot LED indicator Refer to the Gryphon I GBT GM4200 Product Reference Guide PRG for more information about this feature...

Страница 22: ...let the scanner communicate with a Bluetooth host using the Bluetooth Serial Port Profile SPP 1 If using a Bluetooth adapter on the host device install any driver provided with the adapter 2 Scan the...

Страница 23: ...ther the host device or the scanner 4 On the host device open the program that is meant to receive the incoming data The data transmitted by the scanner will appear in the program as if it was typed u...

Страница 24: ...other than those listed in this manual see the Gryphon I GBT GM4200 Product Reference Guide PRG available online at www datalogic com Interface Selection The reader will support all the following host...

Страница 25: ...bar code prior to scan ning an interface selection bar code Some interfaces require the scanner to start in the disabled state when powered up If additional scanner configuration is desired while in...

Страница 26: ...wered by it No additional power supply is required When using a USB interface the reader auto detects the USB cable and defaults to the USB keyboard interface USB Select USB Keyboard with standard key...

Страница 27: ...BD AT AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Standard Key Encoding Select KBD AT NK IBM AT PS2 with standard key encoding but without external keyboard Select KBD AT ALT AT PS 2 25 286 30 286 5...

Страница 28: ...Wedge for IBM AT PS2 with standard key encoding but without external keyboard AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 without Alternate Key Keyboard Wedge for IBM AT PS2 without alternate key enco...

Страница 29: ...support ONLY the following Country Modes U S Belgium Britain France Germany Italy Spain Sweden COUNTRY MODE ENTER EXIT PROGRAMMING MODE Country Mode U S Country Mode Belgium Country Mode United Kingdo...

Страница 30: ...terface 20 GRYPHON I GBT GM4200 COUNTRY MODE CONTINUED Country Mode France Country Mode French Canadian Country Mode Germany Country Mode Hungary Country Mode Italy Country Mode Japanese 106 key Count...

Страница 31: ...ng the Interface QUICK REFERENCE GUIDE 21 COUNTRY MODE CONTINUED Country Mode Norway Country Mode Poland Country Mode Portugal Country Mode Romania Country Mode Slovakia Country Mode Spain Country Mod...

Страница 32: ...Configuring the Interface 22 GRYPHON I GBT GM4200 Supports only the interfaces listed in the Country Mode feature description COUNTRY MODE CONTINUED Country Mode Switzerland...

Страница 33: ...e once to enter Programming Mode scan the desired parameter settings scan the ENTER EXIT bar code again to accept your changes which exits Programming Mode and returns the reader to normal operation C...

Страница 34: ...tting of the Numbers Lock Numlock key while in keyboard wedge interface This only applies to alternate key encoding interfaces It does not apply to USB keyboard default value NUMLOCK ENTER EXIT PROGRA...

Страница 35: ...es the format in which the reader sends character data This applies to keyboard wedge interfaces This does not apply when an alternate key encoding key board is selected default value CAPS LOCK STATE...

Страница 36: ...ion time and if no code is decoded will switch on again before the next acquisition The illuminator will remain on until the symbol is decoded As you read code symbols adjust the distance at which you...

Страница 37: ...Reading Parameters QUICK REFERENCE GUIDE 27 default value GREEN SPOT DURATION CONTINUED Long 800 ms...

Страница 38: ...Trigger Hold Multiple When the trigger is pulled scan ning starts and the product scans until the trigger is released or maximum scan on time 1 has elapsed Read ing a label does not disable scanning D...

Страница 39: ...Operating Modes QUICK REFERENCE GUIDE 29 default value SCAN MODE ENTER EXIT PROGRAMMING MODE Trigger Single Trigger Pulse Multiple Trigger Hold Multiple Flashing Always ON Stand Mode...

Страница 40: ...CTERISTICS Power Supply WLC4190 4 5VDC 14VDC 5 Consumption Typical Gun Only 750mA Cradle Only 70mA Cradle with Gun in Charge 380mA PC host USB 1030mA 5V host Type C 400mA 12V on USB external powered c...

Страница 41: ...mum 15 READING CHARACTERISTICS DOFa a The depth of field is defined by an arc and not a plane Shorter bar codes of a given resolution can be read at a further distance than longer bar codes as explain...

Страница 42: ...cal LOGMARS Code 39 w standard check digit enabled Danish PPT Code 32 Italian Pharmacode 39 Code 128 Code 128 ISBT Interleaved 2 of 5 Standard 2 of 5 Interleaved 2 of 5 CIP HR Industrial 2 of 5 Discre...

Страница 43: ...LED blinks until enumeration with the host is completed Reader beeps four times at highest frequency and volume upon power up Good Read Upper green LED comes on for programmed time default LED behavi...

Страница 44: ...bel is unreadable Check the label to ensure it is not defaced Try to scan another bar code type Distancebetween reader and bar code is incorrect Move reader closer to or further from the bar code Bar...

Страница 45: ...whole unit consumable items 7 use of counterfeit or replacement parts that are neither manu factured nor approved by Datalogic for use in Datalogic manufactured Products 8 any damage or malfunctioning...

Страница 46: ...its website Log on to www datalogic com For quick access from the home page click on the search icon and type in the name of the product you re look ing for This allows you access to download Data Sh...

Страница 47: ...The cleaners and disinfectants listed below are recom mended for use on Datalogic Disinfectant Ready Enclo sures WARNING Be sure to turn off power and unplug the device from electrical outlet before...

Страница 48: ...esidue of the cleaning agent and ensure the unit is dry Clorox Bleach Clorox Healthcare Bleach Germicidal Cleaner Sodium Hypochlorite Sodium Hydroxide Hydrogen Peroxide 3 ProSpray Wipes Disinfectant t...

Страница 49: ...y remove the battery cable out of its connec tor and extract the battery pack from its slot NOTE Before proceeding read Battery Safety on page 41 To ensure maximum performance Data logic recommends th...

Страница 50: ...the new battery in the same position 4 Plug the battery cable into its connector 5 Insert the cover in the handle and screw it into place NOTE When inserting the new battery into the handle take care...

Страница 51: ...ollowing page WARNING Do not place the battery pack in fire or heat Do not connect the positive terminal and neg ative terminal of the battery pack to each other with any metal object such as wire Do...

Страница 52: ...mble or modify the battery The bat tery contains safety and protection devices which if damaged may cause the battery to gen erate heat explode or ignite CAUTION DO NOT place the battery in or near fi...

Страница 53: ...pean Directive 2006 66 EC 2011 65 EU 2002 96 EC and 2012 19 EU and subse quent modifications US and China regulatory and other laws and regulations about the environment CAUTION Storage of batteries f...

Страница 54: ......

Страница 55: ......

Страница 56: ...s mitted in any form or by any means or for any purpose without the express written permission of Datalogic S p A and or its affiliates Datalogic and the Datalogic logo are registered trademarks of Da...

Отзывы: