READING FEATURES
85
9
Auto PackTrack Parameter Descriptions
By means of the software tool DLAPC, it is possible to perform the Auto PackTrack setup
procedure for PackTrack™ and Continuous Operating Mode applications.
Select the "DLAPC" option from the Tools menu or click on the related icon on the Tool Bar
to open the following dialog box:
Once the DLAPC window has been opened, set the following parameters according to the
application requirements:
Sensor Type
: whether calibration will be performed using the system Presence Sensor and
Encoder (most cases), or the PPA-8000 Photocell Array.
NOTE
The Auto PackTrack procedure
requires
using the PPA-8000 Photocell
Array for all systems where either the Presence Sensor or the Encoder are
absent (including Continuous Operating Mode and Cargoscan applications).
If using the Presence Sensor and Encoder, the presence sensor must be connected to the
CBX100/500 I1 input. The Encoder Step parameter must also be set correctly.
If using the PPA-8000 you must set the Photocell distance (165 mm default). The Photocell
Array must be connected to the CBX100/500 I1 and I2 inputs (see the relative installation
manual),
and the Encoder, if present, must be disconnected
.
Pack Version
: the version of the PCT-8000 being used for calibration. This value can be
read from the barcode labels on the PCT-8000. Each label has the value
vnnn
where
v
is the
version number.