DS6500
34
2
2.6.2 “45° Skew” Installation
The DS6500 scanner is mounted on the ST-210 90° mounting bracket (see Figure 18). By
adjusting the mounting bracket guides, reach 45° for the Skew angle (
S
in the figure below)
to avoid the direct reflection of the laser light emitted by the scanner:
Figure 57 – 45° Skew Installation
ATTENTION
If using the “45° Skew” installation, it is not guaranteed that the scanner
reading performances (see reading diagrams in par. 4.4.1) will match
those measured for the standard installation with Skew angle between
10° - 20°.
NOTE
The ST-210 mounting bracket is an accessory of the DS6500 standard
model available in the US-60 kit (890001020).
2.7 TYPICAL
LAYOUTS
The following typical layout refers to the system hardware configurations, but it also requires
the correct setup of the software configuration parameters (see par. 3.2.1 for details).
Other layouts require the use of DS6500 scanner having a specific decoder base.
The accessories and cables indicated in the following figures are Datalogic products. We
suggest their use to guarantee the correct system functioning.
2.7.1 Point-to-Point
Using a Point-to-Point layout, the data is transmitted on the Main interface as well as on the
Auxiliary interface. The Main interface can be selected for RS232 or RS485 full-duplex
communications.
Two different layouts are available according to the DS6500 reader model used for the
connection.
45º
S
Содержание DS6500 Series
Страница 1: ...DS6500 Reference Manual ...
Страница 2: ......
Страница 3: ...DS6500 REFERENCE MANUAL ...