INSTALLATION
2
2.3.1 Power
Supply
The following pins of the DS1100 connector are used:
13/9
25
VS
GND
1
CHASSIS
USER INTERFACE
GND
V+ (5 Vdc)
DS1100
Figure 6 - Power Supply Connections
The power must be 5 Vdc only.
2.3.2
Main Serial Interface - RS485 Half-Duplex
The RS485 half-duplex interface (3 wires + shield) is used for polled communication
protocols.
It can be used for Multidrop connections in a Master/Slave layout or with a Datalogic
Multiplexer, (see par. 2.6.2 and 2.6.3) exploiting a proprietary protocol based on
polled mode called MUX32 protocol, where a master device polls slave devices to
collect data.
The connector pinout follows:
Pin
Name Function
5
RS485 transmitted/received data +
4
RTX485 -
RS485 transmitted/received data -
7
SGND signal
ground
5
4
7
RS485 Ref
USER INTERFACE
DS1100
RTX485 -
SGND
RTX485 -
Figure 7 - RS485 Half-Duplex Connections
9