5.2.2 Adjust the Skew
To adjust the laser skew, loosen the screws securing the front of each UMB to its back and
use a flathead screwdriver to carefully pry the front of the UMB up and down using the
adjustment slots until the laser is exactly 90° to the conveyor. Again, use the edge of the box
as a guide. When adjusted correctly, tighten the UMB screws. Repeat this process for each
dimensioning head.
Figure 52: Adjusting the Skew
Adjust the skew
of the laser until
it is 90° to the
conveyor.
Adjustment Slots