INSTALLATION
2
POWER POLARITY ERROR
(red) indicates a wrong polarity. While activated, all other
LEDs will be off until the power feed is connected with
correct polarity.
2.9 SPECIAL NOTES FOR MATRIX READER SETUP
CAUTION
When connected to a C-BOX 4x0 through the 25-pin connector, the
9-pin Auxiliary port connector on the Matrix reader cannot be used
for communication (i.e. configuration through VisiSet™). The Matrix
reader can only be configured through the 9-pin connector inside
the C-BOX 4x0 and the C-BOX 4x0 must first be configured. see
the following paragraphs for details.
2.9.1
Preparing C-Box 4x0 for Matrix Reader Communication
This paragraph describes how to configure a C-BOX 4x0 so that a Matrix reader can
communicate through the C-Box4x0 and also be configured through its Auxiliary
RS232 interface.
1. Open the C-BOX 4x0;
2. Move
the
Configuration Switch
from the Normal Operation to the CFG position;
3. Connect the 9-pin internal connector of the C-BOX 4x0 to the PC (using a
crossover cable) and run the Winhost™ configuration tool;
4. Select
the
Connect
option to open communications with the C-BOX 4x0 and
wait until the correct communication speed has been determined;
5. From the SCANNER INTERFACE menu, set
Auto Connect
: Disabled
and verify
Data Source
: Main Interface
and save the configuration to the C-Box 4x0 (refer
to Figure 17);