background image

www.automation.datalogic.com

C-BOX 150

Installation Manual

Содержание C-BOX 150

Страница 1: ...www automation datalogic com C BOX 150 Installation Manual ...

Страница 2: ...thout prior notification Datalogic shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from the use of this material Product names mentioned herein are for identification purposes only and may be trademarks and or registered trademarks of their respective companies Datalogic Automation S r l 2002 2007 821001271 R...

Страница 3: ...ssis Grounding Jumper Settings 12 2 4 4 Scanner Selection 12 2 4 5 RS485 Bus Termination 13 2 4 6 Powering C BOX 150 From A Scanner 13 2 4 7 OM4000 Jumper Settings 14 2 4 8 Configuration Switch And 9 Pin Internal Connector 14 2 5 Operating Modes 16 2 5 1 GET TEST SEND Functions 16 2 5 2 LED Indicators 18 2 6 Typical Layouts 20 2 6 1 1000 2000A N 4000 Family Scanners 20 2 6 2 2000N Family Scanners ...

Страница 4: ...is is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures WEEE COMPLIANCE ENGLISH Information for the user in accordance with the European Commission Directive 2002 96 EC At the end of its useful life the product marked with the crossed out wheeled wastebin must be disposed of separately from urban w...

Страница 5: ...den sie das Produkt erworben haben oder besuchen sie unsere Hompage unter www automation datalogic com FRANÇAIS Information aux utilisateurs concernant la Directive Européenne 2002 96 EC Au terme de sa vie utile le produit qui porte le symbole d un caisson à ordures barré ne doit pas être éliminé avec les déchets urbains Éliminer ce produit selon cette Directive permet de éviter les retombées néga...

Страница 6: ...GENERAL VIEW C BOX 150 2 3 1 Figure A 25 pin scanner connector Cover screws 4 Compression connectors 1 2 3 vi ...

Страница 7: ...olarity error LED red 5 4 RS485 Bus termin switch Scanner selection switch 10 INT 30 power connector 11 12 Auxiliary port connector OM4000 jumpers 13 Warning LED red 14 Status LED 6 Power on LED green 7 GET button 8 TEST button 15 Spring clamp terminal blocks 16 Tx LED 17 Configuration switch 9 SEND button 18 Power source jumper vii ...

Страница 8: ...l 4 Set all the proper configuration jumpers and switches according to your application See all sub paragraphs under 2 4 5 Connect the scanner to the C BOX 150 6 Switch on the system 7 Wait until the Warning Led WL red is switched off 8 Through the internal 9 pin male connector it carries the Scanner Aux Serial Port signals configure the scanner according to your specific application using either ...

Страница 9: ... scanner Therefore the substituted scanner will be correctly configured The C BOX 150 allows you to perform the following functions Facilitate the connection of the scanner signals using a spring clamp connector Get the scanner configuration and store it in memory Force the scanner to the Test operating mode Send the configuration stored in memory to the scanner The C BOX 150 mechanical dimensions...

Страница 10: ...wing scanners through the 25 pin connector illustrated in Figure A Scanner Configuration Tool DS1100 WinHost DS2100A WinHost DS2100N Genius DS2200 WinHost DS2400A WinHost DS2400N Genius DS4600A WinHost DS6X00 Genius DX6400 Genius DS8100A Genius DX8200A Genius 10 and 30 Vdc versions only 2 ...

Страница 11: ...0 and all the parts supplied with the equipment are present and intact when opening the packaging the list of parts includes 1 C BOX 150 2 Installation manual 3 C BOX 150 configuration CD ROM 4 2 mounting screws 5 Grounding cable 3 1 2 4 5 Figure 1 C BOX 150 Package Contents 3 ...

Страница 12: ... open it by unscrewing the four cover screws CAUTION The C BOX 150 must be disconnected from the power supply during this operation Figure 2 Opening the C BOX 150 It is possible to perform the following operations Proceed with the cable connections see paragraph 2 4 2 Mount the C BOX 150 to a wall or panel 4 ...

Страница 13: ... The diagram below gives the overall dimensions of the C BOX 150 and may be used for its installation mm inch Ø3 5 Ø0 14 12 0 47 66 2 60 12 0 47 5 0 20 150 5 91 5 0 20 40 1 57 161 6 34 90 3 54 89 8 3 54 114 5 4 51 Figure 3 Overall Dimensions 5 ...

Страница 14: ...e 4 To mount the C BOX 150 1 Open the C BOX 150 by unscrewing the 4 cover screws If necessary using the two mounting holes inside the device as a pattern mark the panel with an appropriate object and then drill two holes in the panel 2 Align the C BOX 150 and insert two screws and screw them into the panel until tight see Figure 4 Figure 4 Mounting C BOX 150 6 ...

Страница 15: ...rnal spring clamp connectors The scanner configuration and data monitoring are possible once the warning LED is turned OFF The internal 9 pin connector can also be used to configure the C BOX 150 with a PC through the WinHost utility After making system cabling and switch settings connect the scanner to the 25 pin connector on the left side of the C BOX 150 housing Switch ON the C BOX 150 power sw...

Страница 16: ...in the package to improve the C BOX 150 noise immunity Simply connect its open end to the scanner cable s fixing screw and the other end to the ground as shown in the figure below 2 4 1 Power Supply Power is supplied to the C BOX 150 through the pins provided on the spring clamp connector The power switch see Figure 6 switches the power supply ON or OFF for both the C BOX 150 and the connected sca...

Страница 17: ...olarity reversal A dedicated red LED signals this condition until correct polarity is restored 2 4 2 System Wiring The connection and wiring procedure for C BOX 150 is described as follows 1 Open the C BOX 150 as described in paragraph 2 2 2 Verify that the C BOX 150 power switch is off see Figure 6 3 Unscrew the compression connectors and pass all the system cables through them into the C BOX 150...

Страница 18: ...ext to the clamp see Figure 8 Insert the wire into the clamp and release the lever The wire will now be held in the spring clamp Figure 8 System Cable Connections The wiring used can be solid or stranded but must meet the following specifications All positions 24 16 AWG 0 2 1 5 mm 10 ...

Страница 19: ...2 IN1 IN 2 ENC B 31 NC NC NC IN2 IN 3A 32 NC NC NC IN2 IN 4A 33 RESERVED RESERVED RESERVED RESERVED IN 3A 34 RESERVED RESERVED RESERVED RESERVED IN 4A 36 NC RTSA ID NET GND IN 3B IN 4B 38 NC CTSA ID NET SGND AUX GND 39 SGND SGND GND SGND GND DS2100A N DS2400A N DS4600A DS6X00 DX6400 DS8100A DX8200A RS232 RS485FD RS485HD 20mA CL with INT 30 only 11 15 TX232 TX485 RTX485 12 16 RTS232 TX485 RTX485 17...

Страница 20: ...ood earth ground or to the power supply ground signal The scanner chassis can also be left floating but in this case the jumper must be removed Figure 9 Chassis Grounding 2 4 4 Scanner Selection DS1100 DS2200 Other Devices floating to EARTH GROUND default to GND Figure 10 Scanner Selection Switch This switch must be set upward only when a DS1100 or a DS2200 scanner 10 30 V version is connected For...

Страница 21: ...his resistor MUST NOT be enabled OFF position 2 4 6 Powering C BOX 150 From A Scanner In order for C BOX 150 to accept power from the scanner through the 25 pin connector instead of the external power supply a jumper can be positioned as indicated in Figure 12 This is useful for example in a typical Master Slaves layout with a Power Supply Unit connected to the scanners see paragraph 2 6 or to pas...

Страница 22: ...s pin 20 to pin 28 EXT TRIG If the jumpers are removed pin 20 and pin 40 are disconnected 2 4 8 Configuration Switch And 9 Pin Internal Connector The 9 pin internal connector may have two different functions according to the position of the configuration switch Figure 14 Configuration Switch and 9 pin Male Connector POSITION MODE Normal Operation default In this position the C BOX 150 is in the no...

Страница 23: ... the C BOX 150 configuration see table below The C BOX 150 enters configuration mode and waits to be configured through WinHost see WinHost Help On Line Once the C BOX 150 configuration is completed it is necessary to return the switch in the Normal Operation position At the end of the reboot phase the C BOX 150 is ready to function with the new configuration 9 pin C Box 150 connector pinout in Co...

Страница 24: ...ing mode the scanner reads barcodes and communicates with the host Also in this mode through the C BOX 150 internal buttons it is possible to communicate with the scanner to perform one of the three GET TEST SEND Functions see paragraph 2 5 1 Configuration CFG When the CFG switch is in CFG position left it is possible to configure the C BOX 150 parameters through WinHost 2 5 1 GET TEST SEND Functi...

Страница 25: ...X 150 preserves this configuration also when switched off The GET option can be disabled through WinHost TEST center button The C BOX 150 forces the WinHost compatible scanners only to run the Test Operating Mode refer to the scanner Reference Manual for details Press any button to quit the Test Operating Mode and restore the scanner normal operating mode For Genius compatible scanners you should ...

Страница 26: ...POWER POLARITY ERROR red indicates a wrong polarity While activated all other LEDs will be off until the power feed is connected with correct polarity WARNING WL red indicates a warning or error condition Off the C BOX 150 has terminated the Connection and or the Update phase all the operations have been executed successfully ON during a connection procedure and or the Update phase the system is b...

Страница 27: ...ry is empty no configuration on board 1 blinking sec the memory is not empty a Get scanner configuration service has been executed 2 blinking sec the memory is not empty a Get Scanner Configuration service has been executed however the saved configuration is not compatible with the current scanner one TRANSMISSION TX green indicates there is communication between the C BOX 150 and the scanner This...

Страница 28: ...rate in a point to point single scanner configuration a typical layout is shown below and the C BOX 150 is connected as follows Laptop Host Scanner 1 2 3 1 2 3 Main serial interface Auxiliary serial interface Local Echo External Trigger for On Line mode PWR supply C BOX 150 Figure 17 Typical point to point scanner Layout 20 ...

Страница 29: ...ical ID NET scanner Layout C BOX 150 can perform Backup Restore of a whole cluster under the following conditions the Master Slave network is composed of one master and up to 9 Slaves maximum the Master Slave network must be either Synchronized or Multidata In order to perform Backup Restore of Master only the C BOX 150 Cluster GET SEND parameter must be configured to Master only see the WinHost H...

Страница 30: ...e 4 Slave 3 PWR 240 CAB 63XX Figure 19 Typical Lonworks scanner Layout NOTE In a Master Slave layout with a great number of Slaves a Power Supply Unit can be connected to the scanners and the C BOX 150 can accept the scanner power by setting the Power Source Jumper in the right position See paragraph 2 4 6 C BOX 150 can perform Backup Restore of a whole cluster under the following conditions the M...

Страница 31: ...ster only see the WinHost Help On Line 2 7 SCANNER REPLACEMENT If you have to replace the scanner with another one 1 Switch off the system 2 Connect the new scanner 3 Switch on the system 4 Wait until the Warning Led WL red is switched Off Now the new scanner has been automatically default updated with the correct configuration 23 ...

Страница 32: ...S Parameter storage Non volatile internal memory ENVIRONMENTAL FEATURES Operating temperature 10 to 50 C 14 to 122 F Storage temperature 20 to 70 C 4 to 158 F Humidity max 90 non condensing Vibration resistance IEC 68 2 6 test FC 14 mm 2 to 10 Hz 1 5 mm 13 to 55 Hz 2g 70 200 Hz 2 hours on each axis Shock resistance IEC 68 2 27 test EA 30g 11 ms 3 shocks on each axis Protection class IP64 when corr...

Страница 33: ...ating to electromagnetic compatibility and product safety Basée sur la législation des Etats membres relative à la compatibilité électromagnétique et à la sécurité des produits Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilid...

Страница 34: ...www automation datalogic com C BOX 150 Installation Manual ...