PRODUCT REFERENCE GUIDE
271
CHAPTER 6
AV500 CALIBRATION
The AV500 Camera can be set up as a single unit or with multiple AV500s in a scanning
array (tunnel). The AV500 camera system is a high
‐
precision imaging system, and
requires careful and accurate setup and calibration to function at its full potential.
REVIEW MOUNTING DRAWING AND APPLICATION
SPECIFICATIONS
Make sure all equipment is mounted correctly based on the application drawings and
specifications.
•
AV500 Deflection Mirror Alignment
‐
Reference the application drawing and
sec-
tion “Installing the Deflection Mirror” on page 34
for deflection mirror placement
and mounting.
•
Photoelectric Sensor, Trigger (if applicable)
‐
Mount the photoelectric sensor
according to the application drawing, and with the following recommendations:
•
Make sure the Photoelectric Sensor (PS) is square to the conveyor
•
Make sure the PS is high enough off of the conveyor surface that it will not get
false triggers from any part of the conveyor
•
Make sure the PS is aligned properly to the reflector. (In a sender receiver applica
‐
tion, make sure the two components are aligned correctly)
•
Make sure the PS is xxxx mm [x in] or greater upstream from the scan line (if appli
‐
cable).
•
If using any one of the additional focusing devices, see
.
AV500 SOFTWARE UPDATE
If necessary, a Datalogic technician will update the AV500 CPU with the latest software.
This must only be done by, or under the guidance of, a trained Datalogic technician.
You will need to connect a laptop to the AV500 in order to perform static and dynamic
calibration, You may use any of the three Ethernet ports; Image, Host or Sync:
•
Sync IP:
•
Host default IP:
•
Image default IP:
DO NOT use a parameter file from any previous AV500 installations.
Содержание AV500
Страница 1: ...AV500 PRODUCT REFERENCE GUIDE 2D CAMERA...
Страница 53: ...MOUNTING PRODUCT REFERENCE GUIDE 33...
Страница 73: ...CBX510 CONNECTION BOX PRODUCT REFERENCE GUIDE 53 Photoelectric Sensor to CBX510 NPN...
Страница 74: ...ELECTRICAL INSTALLATION 54 AV500 2D CAMERA Photoelectric Sensor to CBX510 PNP...
Страница 84: ...ELECTRICAL INSTALLATION 64 AV500 2D CAMERA Photoelectric Sensor to CBX100 and CBX800 NPN...
Страница 86: ...ELECTRICAL INSTALLATION 66 AV500 2D CAMERA...
Страница 91: ...FOCUSING DEVICE WIRING PRODUCT REFERENCE GUIDE 71 Unpowered Outputs...
Страница 113: ...OPERATING MODE PRODUCT REFERENCE GUIDE 93...
Страница 203: ...PRODUCT REFERENCE GUIDE 183 12 Click Next Step and the following screen appears...
Страница 205: ...PRODUCT REFERENCE GUIDE 185...
Страница 218: ...E GENIUS 198 AV500 2D CAMERA...
Страница 230: ...E GENIUS 210 AV500 2D CAMERA...
Страница 231: ...PRODUCT REFERENCE GUIDE 211...
Страница 234: ...E GENIUS 214 AV500 2D CAMERA...
Страница 241: ...PRODUCT REFERENCE GUIDE 221 Click on Diagnostic Messages and a Diagnostic Messages window opens...
Страница 249: ...PRODUCT REFERENCE GUIDE 229...
Страница 253: ...PRODUCT REFERENCE GUIDE 233...
Страница 260: ...E GENIUS 240 AV500 2D CAMERA...
Страница 263: ...PRODUCT REFERENCE GUIDE 243 4 Select Auto Learn from the drop down and the following auto learn options appear...
Страница 266: ...E GENIUS 246 AV500 2D CAMERA...
Страница 299: ...AV500 CALIBRATION PRODUCT REFERENCE GUIDE 279...
Страница 321: ...NOTES...
Страница 322: ...NOTES...
Страница 323: ...NOTES...