TURNING ON SEQUENCE
USER MANUAL
65
Sequence using X1 - Command Box connector
Turn ON the main power supply switch in the back panel of the control rack. The laser
marker turns on and goes in booting-up state. During booting up state, the status LED
on the control rack and the status LED on the scan head blink green.
Wait until booting-up has ended: the status LED on the control rack and the status LED
on the scan head are steady green. The laser marker is in WAIT FOR START state.
EXT_KEY
EXT_ENABLE_A
EXT_ENABLE_B
LOW
LOW
LOW
Steady
Figure 61: Wait for start state
Set the Command box input signals as in the table below:
EXT_KEY
EXT_ENABLE_A
EXT_ENABLE_B
HIGH
LOW
LOW
Steady
The status LED on the control rack and the status LED on the scan head are steady
orange. The laser marker is in STANDBY SHUTTER CLOSED state.
Figure 62: Standby Shutter closed state
CAUTION: Controlling the laser marker states using the X1 - Command Box
connector on the control rack back panel requires that the Key Selector is
set to fixed position
LASER_ON
.
STATE
X1 - COMMAND BOX
INPUT STATE
KEY
SELECTOR
STATUS LED
WAIT FOR START
STATE
X1 - COMMAND BOX
INPUT STATE
KEY
SELECTOR
STATUS LED
STANDBY SHUTTER
CLOSED
Содержание AREX 401
Страница 1: ...AREX 401 USER MANUAL InfraRed Fiber Laser Marker...
Страница 66: ...SET UP 58 AREX 401 Figure 51 Connecting the monitor NOTE Minimum monitor resolution 800 x 600 VGA standard...
Страница 113: ...SLO INTEGRATION EXAMPLE USER MANUAL 105 SLO INTEGRATION EXAMPLE...
Страница 140: ...RECOVER THE LASER MARKER 132 AREX 401 Press FINISH to continue Press YES to continue...
Страница 141: ...HOW TO RECOVER THE LASER MARKER USER MANUAL 133 Wait for disks restoring The system will restart automatically...
Страница 145: ...USER MANUAL 137 APPENDIX G MECHANICAL DRAWINGS...
Страница 146: ...MECHANICAL DRAWINGS 138 AREX 401 CONTROL RACK NOTE Please refer to Datalogic website for detailed drawings...
Страница 147: ...SCAN HEAD USER MANUAL 139 SCAN HEAD NOTE Please refer to Datalogic website for detailed drawings...