TECHNICAL SUPPORT
86
AREX™ 400
TROUBLESHOOTING
If a problem occurs during operation, first check the following troubleshooting. If you
cannot fix the problem, contact Datalogic customer service (see “Technical Support” on
Service Interface
The laser marker is equipped with a Service Interface integrated in
Lighter™ Laser Con-
figuration - Service
useful for service purpose.
The Service Interface provide the following information:
Laser marker serial number
Shows the FW and HW revision (separated by dot) installed in
the Laser Control Board
Counter of the laser marker working hours expressed in
hours and minutes
Shows the CPU temperature of the Laser Control Board
Shows the temperature measured by BOARD#1 sensor of the
control rack
Shows the temperature measured by BOARD#2 sensor of the
control rack
Shows the internal temperature of the Scan Head
DESCRIPTION
This counter is incremented every time the system tempera-
ture is out of the operating temperature range
This counter is incremented every time the scan head tem-
perature is out of the operating temperature range
This counter is incremented every time the service interface
detect a MMC error
Counter of the safety functions events. The safety functions
events counter is incremented every time the INTERLOCK or
LASER_STOP safety function are activated
SYSTEM INFO
INFO TYPE
DESCRIPTION
Serial Number
FW revision
System Working Hours
CPU Temperature
BOARD#1 Temperature
BOARD#2 Temperature
Scan Head Temperature
ERROR TYPE
System Temperature error
Scan Head Temperature error
Service Interface erro
SAFETY INFO
INFO TYPE
DESCRIPTION
Safety relay switching
LASER SOURCE INFO
INFO TYPE
DESCRIPTION
Serial Number
Source serial number
Source Working Hour
Counter of the laser source working hours expressed in
hours and minutes
Diode Working Hours
Counter of the source diode working hours expressed in
hours and minutes. The counter starts to count every time
the laser marker is in READY state
Содержание Arex 400
Страница 1: ...AREX 400 USER MANUAL InfraRed Fiber Laser Marker ...
Страница 64: ...NOTE SET UP 56 AREX 400 Figure 7 Connecting the monitor Minimum monitor resolution 800 x 600 VGA standard ...
Страница 145: ...USER MANUAL 137 APPENDIX H MECHANICAL DRAWINGS ...
Страница 146: ...MECHANICAL DRAWINGS 138 AREX 400 CONTROL RACK NOTE Please refer to Datalogic website for detailed drawings ...
Страница 147: ...SCAN HEAD USER MANUAL 139 SCAN HEAD NOTE Please refer to Datalogic website for detailed drawings ...