TECHNICAL SPECIFICATIONS
36
AREX™ 400
Table 2: Command Box connector pinout
(*) refers to Lighter™ user's manual “Setting I/O parameters” paragraph to set the signal properties
(**) refers to Lighter™ user's manual
(***) see “Input/Output specifications” on page 41
Muting Device
Sub-D, 25 pins, male, with shell.
Figure 10: Command Box Muting Device provided
Internal electric diagram
Figure 11: Command Box Muting Device electric diagram
21
GND
Ground
Ground reference
22
ENABLE_OUT
Digital Output
This signal is used to know if the laser marker is ready to emit laser radia-
tion:
- ON when the laser marker is in READY state
23
SW_READY*
Digital Output
Depending on the configuration this signal can be used in different ways:
- COMPATIBILITY: ON when a document or a sequence is running in AUTO
MODE** or WORK MODE** independently from the laser marker state. The
signal is ON regardless of whether the laser marker is ready to start a new
marking
- STANDARD: ON when a document or a sequence is running in AUTO
MODE** or WORK MODE** and the laser marker state is READY. The signal
is ON regardless of whether the laser marker is ready to start a new mark-
ing
- READY TO MARK: ON only when a document or a sequence is running in
AUTO MODE** or WORK MODE** and the laser marker state is READY. The
signal is ON only if the laser marker is ready to accept a new
START_MARKING event (loading/spooling already executed)
This signal can also be driven using Lighter™ Script engine
"IoPort.setReady (true)" function
24
GND
Ground
Ground reference
25
GND
Ground
Ground reference
PIN
SIGNAL
TYPE***
DESCRIPTION
CAUTION
If the Command Box Muting Device provided is connected, the laser marker
enable is bypassed
.
Содержание Arex 400
Страница 1: ...AREX 400 USER MANUAL InfraRed Fiber Laser Marker ...
Страница 64: ...NOTE SET UP 56 AREX 400 Figure 7 Connecting the monitor Minimum monitor resolution 800 x 600 VGA standard ...
Страница 145: ...USER MANUAL 137 APPENDIX H MECHANICAL DRAWINGS ...
Страница 146: ...MECHANICAL DRAWINGS 138 AREX 400 CONTROL RACK NOTE Please refer to Datalogic website for detailed drawings ...
Страница 147: ...SCAN HEAD USER MANUAL 139 SCAN HEAD NOTE Please refer to Datalogic website for detailed drawings ...