2.3 MARKING AREA SPECIFICATION
Datalogic provides a wide range of F-Theta scan lenses to be attached to the scanning head to focus the
laser beam in flat Marking Field, in order to achieve high-resolution marking results.
These F-Theta scan lenses are available to best-match the object (i.e.: logo; string; 2D matrix; etc.) to be
marked with customer need, over the material processing, and fit the standard Datalogic Scanning Head;
further solutions about different models of lenses and scanning heads will be considered upon request.
The table below lists the standard F-Theta scan lenses currently available:
F-Theta Scan Lens diameter: M39
F-Theta Scan Lens
ƒ
= 160S
ƒ
= 254S
Working Distance
mm
183 ± 5
280 ± 4
Fixing Distance
mm
197 ± 6
300 ± 5
Marking Area
mm
2
85 x 85
100 x 100
F-Theta Scan Lens diameter: M85
F-Theta Scan Lens
ƒ
= 160L
ƒ
= 254L
ƒ
= 330L
Working Distance
mm
176 ± 2
296 ± 5
388 ± 6
Fixing Distance
mm
212 ± 3
367 ± 6
471 ± 7
Marking Area
mm
2
100 x 100
170 x 170
210 x 210
NOTE:
Definition of Marking Area:
square marking field within which power is > 95% respect to power in
center
.
WARNING!
This product was designed to use only certain configurations of F-Theta lens and marking field. If
your needs are not satisfied by current available F-Theta lens configurations please contact
Datalogic for a solution. The use of other F-Theta lenses or operation outside the specified marking
field for a certain F-Theta lens configuration can lead to damage of F-Theta lens, scanning head or
laser source. Such damage is not covered by warranty!
WARNING!
For each F-Theta lens configuration Datalogic recommends the use of certain adapter. This adapter
ensures that residual back reflections caused by F-Theta lens do not damage optics of the scanning
head. The removal of such adapter or its incorrect use (for example incomplete threading, use of
another F-Theta lens adapter, etc.) can lead to damage of the F-Theta lens, scanning head or laser
source. Such damage is not covered by warranty!
Содержание Arex 30W
Страница 1: ...USER S MANUAL ArexTM 30W 50W ...
Страница 26: ...AREXTM 30W 50W 26 2 2 4 2 1 ENABLE SIGNAL S SCHEME COMMAND BOX CONNECTOR Figure 15 ENABLE signal s scheme ...
Страница 49: ...USE AND OPERATION 49 4 Edit Filling properties such as filling type interline etc using the Properties browser ...
Страница 92: ...92 APPENDIX G MECHANICAL DRAWINGS ...
Страница 93: ...93 NOTE Please refer to Datalogic website for detailed drawings ...
Страница 96: ......