background image

DKG-116  User Manual                        

                             

                       V-02 (

11.08.2010)

 

 

 

 

Tel: +90-216-466 84 60 
http://www.datakom.com.tr

 

Fax: +90-216 364 65 65 
[email protected] 

 

DKG-116 MANUAL AND REMOTE START UNIT 

  

 

DESCRIPTION 

The DKG-116 is a low cost 
gasoline/diesel genset control unit 
designed to start and stop a genset both 
manually and remotely.  

The manual control is made using 

RUN

 

and 

STOP

 pushbuttons on the front 

panel. The remote control is made via 

REMOTE START

 input signal. 

When 

RUN

 button is pressed or a 

Remote 

Start

 signal arrives, the engine will be 

cranked up to 3 times. When it runs, the 
crank relay will be immediately deactivated 
and after 

Holdoff timer

 delay, fault 

checking will be enabled. When the engine 
is running, if a fault condition is detected 
then the engine is shutdown immediately 
and the unit indicates the source of the 
failure through related alarm led. 

If 

STOP

 button is pressed or the 

Remote 

Start

 signal disappears, the genset will 

continue to run during cooldown period. At 
the end of the period the engine will stop.  

The 

MENU

 button selects display 

parameter scroll and allows program 
mode entry and lamp test functions. 

The total engine run hours is kept in a 
tamper-proof non-erasable memory which 
is not affected by power failures. 

MEASUREMENTS 

Generator Volts: L1-N, L2-N, L3-N 
Generator Volts: L1-L2, L2-L3, L3-L1 
Generator Frequency 
Battery Voltage

  

OPTIONS 

Auxiliary output (negative pulling). 

 

 

 

 
 

FEATURES 

Both Manual and remote control 

Generator protection 

Built in alarms and warnings 

Remote Start operation available 

True RMS measurements 

Tamper-proof engine hours display 

Field adjustable parameters 

High current Fuel and Crank outputs 

Protected semiconductor auxiliary 
output 

Digital inputs: 4 

Survives cranking dropouts 

Sealed front panel 

Standard panel dimensions: 96x48mm 

Plug-in connection system 

Содержание DKG-116

Страница 1: ...rce of the failure through related alarm led If STOP button is pressed or the Remote Start signal disappears the genset will continue to run during cooldown period At the end of the period the engine will stop The MENU button selects display parameter scroll and allows program mode entry and lamp test functions The total engine run hours is kept in a tamper proof non erasable memory which is not a...

Страница 2: ...er the programming mode The unit offers 8 programmable parameters listed below NO SYMBOL RANGE FACTORY SET DESCRIPTION 1 U Lo U Lo U Lo U Lo 70 500 V 170 V Low AC voltage shutdown limit 2 U HI U HI U HI U HI 70 500 V 300V High AC voltage shutdown limit 3 nFrq nFrq nFrq nFrq 0 1 0 Nominal frequency 0 50Hz 1 60Hz 4 OIL OIL OIL OIL 0 1 0 Oil input 0 pressure switch 1 level switch 5 FUEL FUEL FUEL FUE...

Страница 3: ...laying the Fuel output type Press RUN or STOP buttons until requested value is displayed Press MENU button for saving the Fuel output type and displaying the Relay 3 function Press RUN or STOP buttons until requested value is displayed Press MENU button for saving Relay 3 function and displaying the Choke timer Press RUN or STOP buttons until requested value is displayed Press MENU button for savi...

Страница 4: ... DC Fuel and Crank outputs 10A 12V DC Auxiliary Output 1A 12V DC negative pulling protected semiconductor output Operating temp 40 C 40 F to 80 C 176 F Maximum humidity 95 non condensing Dimensions 102 x 55 x 40 mm WxHxD Packed weight 140 g Case Material High Temp ABS PC UL94 V0 IP Protection IP65 front panel IP30 rear Conformity EU directives 2006 95 EC low voltage 2004 108 EC EMC Norms of refere...

Отзывы: