![Datafox Evo 4.6 FleKey Скачать руководство пользователя страница 138](http://html.mh-extra.com/html/datafox/evo-4-6-flekey/evo-4-6-flekey_manual_511640138.webp)
Manual Datafox Evo 4.6 FleKey
Page 131
Date: 14.09.2021 V 04.03.17.XX
The list Time contains time model 1. This time model is active 24/7.
Time.txt
ID
Weekdays
TimeStart
TimeEnde
1
1234567
00:00
23:59
The Location list must contain an entry. This entry associated the time model, so that access using
the reader is possible always.
Location.txt
ID
RefGroup
RefTime
RefTimeNoPin
1
0
1
0
In order to open the door, the Identification list must contain an entry that is allowed to open the
door.
Identification.txt
ID
Group Pin Menace ActiveStart
ActiveEnd
ActiveGeneral
2059FB3A 0
0
0
2005-04-01
2020-04-01
1
5.8.12.8. Additional lists
As explained earlier, the ReaderProps list is needed in addition to the
access control list. If digital input 1 changes to low voltage, all doors
being unlocked for a finite time will be locked again. The entry to the
ReaderProps list is as follows:
ReaderPorps.txt
RefReader Type
Mode
RefReaderInput
Input
10
5
0
99
1