3.5.1.3.
I
NSTALLING THE POWER CABLE IN THE
PSU
120
There are two cables (DATACOM code 408.0391.xx) that come out of the PSU1 and PSU2 connectors in
direction of the current distributor. The cable must be positioned a for installation in the current distributor.
For detailed information about PSU 120 cable and connector pinout, consult
into the
chapter
Hardware Description
.
Each cable corresponds to a power supply and if using the redundancy mode must be connected an entirely
independent circuit.
To prevent the risk of electrical shocks, before turning the equipment on or connecting an
interface or cable, install the protective grounding system.
3.5.2.
C
HECKING OPERATION THE
DM4610
CHASSIS
Considering that the DM4610 was installed as described, the following steps may be used to check the unit
operation:
Step 1
•
Just after the power up DM4610, the FAIL LED (red) will remain lit indicating
software load (booting) and POWER LED (green) on.
Step 2
•
Wait until the end of the unit’s start up process and check the condition of the
front LEDs:
•
POWER LED (green) on: The unit is correctly powered.
•
FAIL LED (red) off: The unit did not detect hardware failures.
•
SYS LED (green) on, indicating that this unit of the system is working.
•
ALARM LED (red) off: The unit did not receive any alarm.
Step 3
•
The system is operating correctly, whether the following conditions are
satisfied:
•
POWER LED (green) on;
•
FAIL LED (red) off:
•
SYS (green) on;
•
ALARM LED, does not matter.
When successfully ending the start up process, the operator must configure the management IP address as
described on
Logging in for First Time
.
3.5.3.
I
NSTALLING
M
ANAGEMENT
C
ABLES
These management cables make the initial configuration of the system possible.
3.5.3.1.
C
ONSOLE SERIAL CABLE
The DM4610 has a RS232 serial port provided on the RJ45 connector located on the right of the unit.
DATACOM provides a cable with the function of interlinking the DM4610 to a PC. This connection is only
necessary one single occasion, when starting up the product, when it is necessary to record the IP address in
the DM4610.
Only one adaptor cable for sporadic use is defined in the DM4610. The console serial cable, DATACOM code
710.0137.xx.