DM4170 – Installation Manual
Installing the DM4170
204.4308.03
25
4.7.2
Connecting to Power Supply
After inserting the PSU 125 (s), connect the power supply according to the levels specified in
the
chapter.
Each PSU slot has an independent power input; the DC PSUs have a front power
source, while the AC PSUs have a power source at the rear panel aligned with its
respective slot. The switch will only power on if there is at least one PSU that is
properly powered.
C
HECKING THE PRODUCT
’
S OPERATION
Considering that the DM4170 was installed according to the guidelines in this manual, the
steps below indicate whether the equipment is operating normally.
Step 1
•
Immediately after the unit is powered by either of the power inputs, the
power-on PSU PWR indicator will light up. After
approximately 3 seconds
the switch's PWR LED will light up, followed by a brief blinking of the
ALARM/FAIL LED (red).
Step 2
•
After the startup has finished, observe the ALARM/FAIL indicator:
o
OFF: indicates that the equipment has been initialized and is
operating correctly.
o
RED ON (FAIL): indicates that the machine has encountered an
internal failure.
o
YELLOW/AMBER ON (ALARM): indicates that the equipment has
been initialized correctly, but an alarm is enabled. If you have any
questions, please contact
Table 15 – Checking DM4170 operation
Once the startup process has been successfully completed, the operator must configure the
equipment management as indicated in the
section.