DM4170 – Installation Manual
Installing the DM4170
204.4308.03
31
7
TECHNICAL SPECIFICATIONS
I
NTERFACES
Interfaces
DM4170 24GX+12XS
DM4170 24GX+4XS+2QX
Console (RJ45)
1
Ethernet Management (RJ45)
1
USB Host (type A)
1
USB Device (type B)
1
100Base-Fx/1000Base-X (SFP)
24
10/100/1000Base-T (RJ45)
-
1000Base-X/10GBase-X (SFP+)
12
4
40GBase-X (QSFP+)
-
2
Table 20 - Interfaces DM4170
P
OWER
S
UPPLY
S
PECIFICATIONS
PSU 125 AC
PSU 125 DC
Rated operating voltage
100 to 240Vac (± 10%)
50/60Hz
-48 to -60Vdc (± 20%)
Rated input current
1.5 A @ 100Vac
0.63 A @ 240Vac
3.3 A @ -48Vdc
2.6 A @ -60Vdc
Maximum input current
1.66A
3.90A
Output voltage
12V (± 5%)
Output current
10A (± 5%)
Efficiency
>80%
>80%
Table 21 – Power Inputs