CP60 and CP60 Plus Service Manual
6-65
Duplex Home Sensor (Without Clear Card)
Removal Procedure
1.
Unplug the printer.
2.
Remove the ribbon cartridge and cleaning roller.
3.
Remove the
4.
Disconnect the sensor connector from the duplex interface board.
5.
Carefully push the sensor out of the duplex chassis.
Replacement Notes
•
When pushing the sensor into the duplex chassis, do not push against the
wires or crush them.
•
Print a test card to verify that the duplex is functioning properly.