background image

AD-10 

AUDIO DELAY BOX 

 

Содержание AD-10

Страница 1: ...AD 10 AUDIO DELAY BOX ...

Страница 2: ...IEW 8 1 1 FEATURES 8 2 FRONT PANEL 9 3 RIGHT PANEL 10 4 LEFT PANEL 12 5 DIMENSIONS 13 APPENDIX FIRMWARE UPDATE 16 1 INTRODUCTION 16 2 PREPARATION 16 2 1 SYSTEM REQUIREMENTS 16 2 2 FIRMWARE UPDATE PREPARATION 17 2 3 SYSTEM CONNECTION DIAGRAM 17 2 4 PREPARING THE FIRMWARE 18 2 5 INSTALL THE EPCONSOLE SOFTWARE 18 3 UPDATE 19 3 1 UPDATING THE FIRMWARE 19 SERVICE AND SUPPORT 24 ...

Страница 3: ...complete This manual may contain typing errors omissions or incorrect information Datavideo Technologies always recommend that you double check the information in this document for accuracy before making any purchase decision or using the product Datavideo Technologies is not responsible for any omissions or errors or for any subsequent loss or damage caused by using the information contained with...

Страница 4: ...on To ensure safe and reliable operation of this unit and to protect it from overheating do not block or cover these openings Do not place this unit on a bed sofa rug or similar surface as the ventilation openings on the bottom of the cabinet will be blocked This unit should never be placed near or over a heat register or radiator This unit should not be placed in a built in installation unless pr...

Страница 5: ...d b When liquid has spilled into the unit c When the product has been exposed to rain or water d When the product does not operate normally under normal operating conditions Adjust only those controls that are covered by the operating instructions in this manual improper adjustment of other controls may result in damage to the unit and may often require extensive work by a qualified technician to ...

Страница 6: ...re are not covered All accessories including headphones cables and batteries are not covered under warranty Warranty only valid in the country or region of purchase Your statutory rights are not affected Three Year Warranty All Datavideo products purchased after July 1st 2017 are qualified for a free two years extension to the standard warranty providing the product is registered with Datavideo wi...

Страница 7: ...n point for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste equipment for recycling please contact your local ci...

Страница 8: ... condenser microphone and dynamic microphone and the audio gain control function AD 10 s ruggedized design allows you to install it easily Moreover it can be powered by a standard 5V USB power bank 1 1 Features Supports Audio and Video Synchronization Supports maximum delay time up to 400ms Can be powered by an external USB interface power bank Supports audio level control function Switchable for ...

Страница 9: ...des you 10 segments for adjusting the audio delay time from 40ms to 400ms Moreover it also provides TONE function for you to output a 1K TONE signal to be the test signal Audio Level Adjustment Knob This knob allows you to adjust the volume level of the input audio ...

Страница 10: ...WER This USB Type C interface allows you to connect to a 5V USB external power bank for powering the AD 10 Once the external power bank is connected the power of the AD 10 is turned on F W UPGRADE According to the difference of the USB interface for your laptop please use a USB Type A to USB Type C adapter cable or a USB Type C to USB Type C cable to connect from your laptop to your AD 10 After th...

Страница 11: ...hone AUDIO IN This AUDIO IN interface allows you to connect to a 3 5mm condenser microphone dynamic microphone or other Line in audio input sources MIC 40dB MIC 20dB LINE When you use a microphone this switch allows you to select MIC 40dB or MIC 20dB When you use an external LINE IN audio source please select LINE ...

Страница 12: ... C interface which is located on the right panel of the AD 10 After the connection is done please release the F W UPGRADE button After that please use the EP Console firmware update tool for updating the firmware of the AD 10 MONO STEREO This switch allows you to select the output audio source to be mono or stereo AUDIO OUT R L The AD 10 provides two unbalanced stereo RCA audio output interfaces ...

Страница 13: ...13 5 Dimensions ...

Страница 14: ...ets 600ohm MAX 10dBV Audio Output Switch Stereo Mono MIC Gain LINE Switch MIC 40dB MIC 20dB LINE Input Level Gain Knob Off to18dB gain Audio Output LED Indicator 2 Rows Left Right Audio Delay Knob 0 to 400ms Firmware Update Power In USB Type C 5V 1A Supported MIC power DC 3V Audio Specification Audio Delay Up to 400ms Sample Rate 48 KHz Line Input Bandwidth 20Hz 20KHz 3dB S N Ratio 80 dB 1KHz 0dB ...

Страница 15: ...0dB 20dB 60 dB 1KHz 0dB 40dB T H D 0 03 1KHz 0dB 20dB 0 1 1KHz 0dB 40dB Isolation 60dB 20dB 50dB 40dB General Operating Temperature 0 C to 40 C 32 F to 104 F Storage Temperature 20 C to 60 C 4 F to 140 F Humidity 10 to 80 non condensing Dimension mm 151 x 88 5 x 30 7 Weight kg 0 18 ...

Страница 16: ...bes how to perform a firmware update on a Windows computer Screen images from the Windows 10 operating system are used in this document as an example Images used in this document may differ from the actual screens For details on Windows and computer operations please refer to the instruction manual of your computer 2 Preparation 2 1 System Requirements A computer that meets the following requireme...

Страница 17: ...dating the firmware USB Type A to USB Type C adapter cable x 1 The USB Type C cable for powering and firmware update purposes USB 3 0 supported Laptop x 1 The USB 3 0 supported laptop is used for updating the firmware EPConsole software The EPConsole software is used for updating the firmware Latest Firmware usb_ad10_rls H01 usb_ad10_rls H00 The latest downloaded firmware files 2 3 System Connecti...

Страница 18: ... file After that you can see the following firmware files for the AD 10 2 5 Install the EPConsole Software The EPConsole software is the software which is used for the AD 10 firmware update Please follow the following steps for installing the EPConsole software 2 5 1 Install the EPConsole Software Please go to the Koryo EPConsole website http ap koryo com tw download EPConsole publish htm and then...

Страница 19: ... from the AD 10 Please press the FW UPGRADE button from the AD 10 and then connect a USB type A to USB type C adapter cable from the USB type A port of your laptop to the USB type C port of the AD 10 3 1 2 Please release the FW UPGRADE button Please release the FW UPGRADE button ...

Страница 20: ...e click the EPConsole icon from the Windows Start Menu of your laptop Please click the EPConsole icon from the Windows Start Menu of your laptop to run the EPConsole software and then the USB1 57600 will be shown 2 1 ...

Страница 21: ...21 3 1 4 Please press the FILE button to load the latest firmware files Please press the FILE button to load the latest firmware files 4 3 ...

Страница 22: ...22 3 1 5 Please press the Program MCU button and then wait until the progress bar reaches 100 5 ...

Страница 23: ...23 3 1 6 After the progress bar reaches 100 the Program and Verify BAMK0 BANK1 OK will be shown and the firmware update procedure is done successfully ...

Страница 24: ...https www datavideo com product AD 10 Jul 26 2021 Ver E1 Datavideo Technologies Co Ltd All rights reserved 2020 ...

Отзывы: