Chapter 5
56
Figure 14: Simultaneously Updating the Analog Output Channels of Multiple Modules
In this scheme, you must configure the trigger source for one module (called the master
module) as
Software
. Configure the trigger source for the other DT9850 Series modules
(called slave modules) as an
External Positive TTL
trigger. In this configuration, the
DAC_Sync signal is configured as an output on the master module and as an input on the
slave modules.
To start the operation, issue a single values command on each of the slave modules. Then,
issue a single values command on the master module. In a single values operation, you
specify the output channels to update and the value to write to each analog output channel.
The master module automatically sends a signal from its DAC_Sync pin to the connected
slave modules, allowing the analog output channels of all connected modules to be updated
simultaneously with the values that you specified.
Note:
If you are using continuous output mode, described on
, the DAC_Sync pin
cannot be used to synchronize multiple modules.
On power up and reset, the DAC_Sync pin is an input signal.
DT9850 Series Module
(Master)
DAC_Sync
DT9850 Series Module
(Slave 1)
DT9850 Series Module
(Slave 2)
DT9850 Series Module
(Slave 8)
.
.
.
Output
Input
Input
Input
Trigger source
is External
Trigger source
is External
Trigger source
is External
Trigger source
is Software
Each module perform a single
values operation.
DAC_Sync
DAC_Sync
DAC_Sync
Содержание DT9850 Series
Страница 1: ...DT9850 Series UM 22600 M User s Manual Title Page ...
Страница 4: ......
Страница 8: ...Contents 8 ...
Страница 11: ...11 1 Overview DT9850 Series Hardware Features 12 Supported Software 14 Getting Started Procedure 15 ...
Страница 16: ...Chapter 1 16 ...
Страница 17: ...Part 1 Getting Started ...
Страница 18: ......
Страница 48: ...Chapter 4 48 ...
Страница 49: ...Part 2 Using Your Module ...
Страница 50: ......
Страница 51: ...51 5 Principles of Operation Analog Output Features 53 Digital I O Features 60 Counter Timer Features 62 ...
Страница 76: ...Chapter 6 76 ...
Страница 77: ...77 7 Troubleshooting General Checklist 78 Technical Support 80 If Your Module Needs Factory Service 81 ...
Страница 82: ...Chapter 7 82 ...
Страница 83: ...83 8 Calibration Using the Calibration Utility 84 Calibrating the Analog Output Subsystem 85 ...
Страница 86: ...Chapter 8 86 ...