Chapter 6
84
About-Trigger Acquisition
Use about-trigger acquisition mode when you want to acquire data both before and after a
specific external event occurs. This operation is equivalent to doing both a pre-trigger and a
post-trigger acquisition.
Using software, specify
• The dataflow as ContinuousPrePostTrigger.
• The pre-trigger source as the software trigger.
• The post-trigger source as the external, positive, digital (TTL) trigger.
• If you are using triggered scan mode, the retrigger mode as the software retrigger.
Refer to
for more information on the supported conversion modes; refer to
for
information on the supported trigger sources.
Note:
When using about-trigger acquisition, you cannot use externally-retriggered scan
mode; refer to
for more information on triggered scan mode.
The about-trigger acquisition starts when you start the operation. When it detects the selected
post-trigger event, the board stops acquiring pre-trigger data and starts acquiring post-trigger
data.
If you are using software-retriggered scan mode and the post-trigger event has not occurred,
the board continues to acquire pre-trigger data using the software retrigger clock to clock the
operation. If, however, the post-trigger event has occurred, the board continues to acquire
post-trigger data using the software retrigger clock to clock the operation.
The about-trigger operation stops when the specified number of post-trigger samples has
been acquired or when you stop the operation. Refer to
for more information on
software-retriggered scan mode.
illustrates continuous about-trigger mode using a channel list of two entries:
channel 0 and channel 1. In this example, pre-trigger analog input data is acquired
continuously on each clock pulse of the A/D sample clock until the post-trigger event occurs.
When the post-trigger event occurs, post-trigger analog input data is acquired continuously
on each clock pulse of the A/D sample clock.
Содержание DT300 Series
Страница 1: ...DT300 Series UM 16501 T User s Manual Title Page ...
Страница 4: ......
Страница 10: ...Contents 10 ...
Страница 14: ...About this Manual 14 ...
Страница 15: ...15 1 Overview Features 16 Supported Software 18 Accessories 19 Getting Started Procedure 20 ...
Страница 21: ...Part 1 Getting Started ...
Страница 22: ......
Страница 58: ...Chapter 4 58 ...
Страница 69: ...Part 2 Using Your Board ...
Страница 70: ......
Страница 106: ...Chapter 6 106 ...
Страница 124: ...Chapter 8 124 ...
Страница 125: ...125 9 Troubleshooting General Checklist 126 Technical Support 128 If Your Board Needs Factory Service 129 ...
Страница 130: ...Chapter 9 130 ...
Страница 156: ...Appendix C 156 ...
Страница 164: ...Index 164 ...