UMN:CLI
User Manual
V8102
156
major
|
minor
|
warning
|
intermediate
}
fic threshold over for an Ethernet optical
interface.
snmp alarm-severity adva-if-rcv-fai
l {
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets ADVA severity of an alarm for fail-
ure to receive packets.
snmp alarm-severity adva-if-trans-fault
{
criti-
cal
|
major
|
minor
|
warning
|
intermediate
}
Sets ADVA severity of an alarm for fail-
ure to transmit packets.
snmp
alarm-severity
adva-if-sfp-mismatch
{
critical
|
major
|
minor
|
warning
|
intermedi-
ate
}
Sets ADVA severity of an alarm for SFP
module mismatched.
snmp alarm-severity adva-psu-fail
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets ADVA severity of an alarm for PSU
failure.
snmp alarm-severity adva-temperature
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets ADVA severity of an alarm for sys-
tem temperature high.
snmp alarm-severity adva-voltage-high
{
criti-
cal
|
major
|
minor
|
warning
|
intermediate
}
Sets ADVA severity of an alarm for input
voltage high.
snmp alarm-severity adva-voltage-low
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets ADVA severity of an alarm for input
voltage low.
To delete configured ADVA alarm severity, use the following command.
Command
Mode
Description
no snmp alarm-severity adva-fan-fail
Global
Deletes configured ADVA alarm severi-
ty.
no snmp alarm-severity adva-if-misconfig
no snmp alarm-severity adva-if-opt-thres
no snmp alarm-severity adva-if-rcv-fail
no snmp alarm-severity adva-if-sfp-mismatch
no snmp alarm-severity adva-if-trans-fault
no snmp alarm-severity adva-psu-fail
no snmp alarm-severity adva-temperature
no snmp alarm-severity adva-voltage-high
no snmp alarm-severity adva-voltage-low
7.1.11.7
STP Guard Alarm Severity
To set severity of an alarm for STP guard, use the following command.
Command
Mode
Description
snmp alarm-severity stp-bpdu-
guard
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Global
Sets severity of an alarm for BPDU guard disabled.
snmp alarm-severity stp-root-
guard
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets severity of an alarm for root guard disabled.
Содержание V8102
Страница 1: ...1 V8102 GPON OLT system User Manual...
Страница 158: ...UMN CLI User Manual V8102 158 When you use the no snmp command all configurations of SNMP will be lost...
Страница 427: ...User Manual UMN CLI V8102 427 show debugging dhcp Enable Global Shows the debugging information of DHCP...
Страница 797: ...User Manual UMN CLI V8102 797 show onu gsp status config ONU_ID tag list number TAG_NAME tag name...