background image

65E10 CONTR

OL SERIES

LT56 (IM-65E10-0303)

Instruction Manual

For DC Input Variable Speed Controls

P.0. Box 10
5000 W. 106th Street
Zionsville, Indiana 46077

Phone (317) 873-5211

Fax (317) 873-1105

www.dartcontrols.com

CONTROLS

A-5-3180A

Содержание 65 series

Страница 1: ... SERIES LT56 IM 65E10 0303 Instruction Manual For DC Input Variable Speed Controls P 0 Box 10 5000 W 106th Street Zionsville Indiana 46077 Phone 317 873 5211 Fax 317 873 1105 www dartcontrols com CONTROLS A 5 3180A ...

Страница 2: ...ents All information contained in this manual is intended to be correct however information and data in this manual are subject to change without notice DCI makes no warranty of any kind with regard to this information or data Further DCI is not respon sible for any omissions or errors or consequential damage caused by the user of the product DCI reserves the right to make manufacturing changes wh...

Страница 3: ...present for the control Caution should be used in selecting proper size of hook up wire for current and voltage drop HOOK UP DIAGRAMS WARNING DO NOT REVERSE POSITIVE AND NEGATIVE BATTERY LEADS THIS WILL DAMAGE THE CONTROL TO CHANGE MOTOR DIRECTION INTERCHANGE THE POSITIVE AND NEGATIVE ARMATURE LEADS Refer to the wiring diagrams below for proper connection of DC Voltage Armature and Speedpot wiring...

Страница 4: ...Accel Min Speed Current Limit I R Comp Inhibit P1 9 Common P1 8 Pot Low P1 7 Pot Wiper P1 6 Pot High P1 5 Arm P1 4 Arm P1 3 Battery P1 2 Battery P1 1 P1 5KΩ Speedpot Red Orange Optional Inhibit see hook up below Battery Customer supplied SPST switch or relay White Motor Customer supplied 3PDT Center off Center blocked switch Inhibit P1 9 Common P1 8 Pot Low P1 7 Pot Wiper P1 6 Pot High P1 5 5KΩ Sp...

Страница 5: ...ewly installed control will not operate it is likely that a terminal or connection is loose Check to make sure connections are secure and correct If the control is still inoperative refer to the following chart for reference MODEL SELECTION 24 volt and 36 volt units with the same current ratings are interchangeable ie 24 volt unit will operate with 36 volt input and a 36 volt unit will operate wit...

Страница 6: ...cceleration adjustable 0 to 10 seconds Deceleration non adjustable 0 5 seconds Maximum speed adjustable 50 to 100 of base speed Minimum speed adjustable 0 to 30 of max speed Connections Euro style terminal block 14Ga to 28Ga Speed regulation 1 of base speed via adjustable I R Compensation trimpot Operating temperature 10 C to 45 C 14 F to 113 F Package configuration black anodized aluminum extrusi...

Страница 7: ...6 NOTES ...

Страница 8: ... 1105 Indiana productionandhead quarters facility with over 2 000 000variablespeedunits in the field In addition to the standard off the shelfproducts youcanse lect from a wide variety of op tions to customize controls for your specific application For further information and appli cationassistance contactyour local Dart sales representa tive stocking distributor or Dart Controls Inc Dart Controls...