4.2  Rail mounted version (X100LR) 

 

 

Remove the light from its packaging. 

 

If  you  have  also  purchased  our  XRAIL  accessory,  hold  the  rail  against  the 
selected location on the wall, bearing in mind the final position and range of 
travel of the light-head required to project its light patch where it will be 
needed. 

 

Ensuring the rail is horizontal; mark the positions for the 2 screw holes. 

 

Fix the rail to the wall, using appropriate plugs as necessary and the 2 screws 
provided.  

 

NOTE: Slide the screw-head cap retainers the correct way up onto the screws 
before fitting the screws! 

 

 

Fit the screw-head caps. 

 

Ensure the rail end caps are properly fitted. 

 

Slacken sufficiently the light clamp to allow the clamp to pass over the rail 
and fit the light to the rail. 

 

The light can be moved along the rail by slackening the clamp slightly and not 
sufficiently to allow the light to become detached from the rail. 

 

4.3  Desk mounted versions (X100LD / X100LDS / X100LFDM) 

 

X100LD (includes PIVOTD2 desk clamp) 

 

Remove the light from its packaging.  

 

Slacken the desk clamp so that its jaws just clear the desk edge.  

 

Tighten the clamp sufficiently to provide a rigid mounting for the light.  

 

Fit the spigot on the end of the light arm into the top of the clamp, make 
sure it is fully secured in place. 

 

Apply the power cable, and power the light on. See page 8. 

 
X100LDS (includes PIVOTS weighted base) 

 

Remove the light from its packaging.  

 

Fit the spigot on the end of the light arm into the top of the weighed base, 
make sure it is fully secured in place. 

 

Apply the power cable, and power the light on. See page 8. 

 
X100LFDM (includes PIVOTFDM fixed desk mount)
 

 

Remove the light from its packaging.  

 

Mark the position on the desk for mounting. Use screws the fix the bracket 
securely. 

Содержание X100

Страница 1: ...X100 LED Examination Light Operating Installation Manual QAM X100 1218 10...

Страница 2: ...Page 1 of 22...

Страница 3: ...ons 9 4 1 2 Placement and Installation 10 4 2 Rail mounted version X100LR 12 4 3 Desk mounted versions X100LD X100LDS X100LFDM 12 4 4 Mobile version X100LM 13 4 5 Optional battery back up 14 4 5 1 Pac...

Страница 4: ...The flexible arm allows the light patch to be placed accurately and stably where it is needed All versions are delivered in special to type packaging which identifies on the ends of the box the model...

Страница 5: ...ured in Great Britain by Daray Ltd Edison House Robian Way Swadlincote Derbyshire DE11 9DH 1 1 Supported Lights The Following Models are supported in this Manual X100LW X100 LED Wall Mounted Light X10...

Страница 6: ...x CRI 93 Light Field Diameter D50 0 5m 180mm Light Field Diameter D10 0 5m 240mm Number of LED s 4 Power Consumption 8 5W 0 07A Average Working Life 40 000 Hours Input Voltage 100 240V AC 50 60 Hz Out...

Страница 7: ...FDM S Qty X100LW Qty Plug top transformer 1 Plug top transformer 1 Desk Clamp Fixed Desk Mount Desk Stand 1 Wall bracket fixings 1 Light head and flexible arm 1 Light head and flexible arm 1 User Man...

Страница 8: ...Page 7 of 22 2 3 Technical Drawing...

Страница 9: ...Page 8 of 22 3 2 Powering On Variable Intensity The X100 uses a single button on the back of the head to power the light on and off Press once to power ON Press once to power OFF...

Страница 10: ...to the underside of the bracket dependent on couch height It may be necessary to adjust this height if there are specific medical procedures the light will be used for If in doubt consult the end use...

Страница 11: ...in mind the final position of the light head required to project its light patch where it will be needed We recommend 850 1100mm from the floor to the underside of the bracket dependent on couch heig...

Страница 12: ...light on See page 8 Check arm and head for smooth and correct movement Your new DARAY light is now ready for use To gain full support of our warranty please fill in our warranty web form or contact DA...

Страница 13: ...can be moved along the rail by slackening the clamp slightly and not sufficiently to allow the light to become detached from the rail 4 3 Desk mounted versions X100LD X100LDS X100LFDM X100LD includes...

Страница 14: ...g If not already fitted fit the castors to the base by knocking them sharply into their fixing sockets Insert the up stand into the castor base as shown below Do not use a metal hammer Once fitted the...

Страница 15: ...mobile version of this light please use the extension cable provided NOTE Charging time can take up to 8 hours depending on how depleted the battery is 2 If you need to use the light on battery power...

Страница 16: ...lude Check all electrical connections are sound and that there is no visible cable wear All fixings to be checked and be of sound construction 5 2 Safety Precautions For all cleaning work power off th...

Страница 17: ...ng on painted finishes This is designed to assist with infection control and is not a replacement for cleaning CAUTION Our products are NOT waterproof The equipment and accessories included chargers a...

Страница 18: ...ight 5 4 2 Detaching Parts De construction of the lights should be done following a reverse order of the instructions in section 4 The X100 is a completely enclosed light and arm it should not be open...

Страница 19: ...Visually check fuses then check continuity with meter Cables Check the visible wiring and make sure the DC connectors between the light and the extension cable are fully connected Poor Light output Po...

Страница 20: ...TECHNICAL ISSUES phone DARAY S Service Delivery Team on 44 0 800 878 9864 Opening times 9am 5pm Monday to Thursday excluding bank holidays 9am 2 30pm on Friday Or email support daray co uk IF THE LIGH...

Страница 21: ...red by any of the above We will always try to help but we cannot normally offer a refund For additional clarification please refer to our terms and conditions at www daray co uk terms In a small numbe...

Страница 22: ...Daray s instructions Attachment of fittings and accessories not approved by Daray Repairs modifications carried out by service personnel not approved by Daray Damage caused by chemical corrosion from...

Страница 23: ...Page 22 of 22 Service Notes...

Страница 24: ...Page 23 of 22...

Страница 25: ...Page 24 of 22...

Страница 26: ...Page 25 of 22...

Страница 27: ...Page 26 of 22...

Страница 28: ...DARAY Ltd Edison House Robian Way Swadlincote Derbyshire United Kingdom DE11 9DH 44 0 800 878 9864 44 0 333 321 0973 sales daray co uk www daray co uk...

Отзывы: