1. About this manual 

This manual provides the instructions necessary to operate the V408 fingertip pulse 
oximeter (hereinafter called as the device) in accordance with its function and intended 

use. Observance of this manual is a prerequisite for proper performance and correct 
operation, and ensures patient and operator safety. 
 
This manual is an integral part of and should always be kept close to the device, so that it 
can be obtained conveniently when necessary. Content of this manual is subject to change 

without prior notice. 
 
  

2. Safety Information 

The safety statements presented in this chapter refer to the basic safety information that 
the operator of the device shall pay attention to and abide by. There are additional safety 
statements in other chapters or sections, which may be the same as or similar to the 
followings, or specific to the operations. 

 
The following safety terms warning and caution are used throughout this manual to point 
out hazards and to designate a degree or level or seriousness. 
 

WARNING 

Indicates a potential hazard situation or unsafe practice that, if not avoided, could 
result in death or serious injury. 
 

CAUTION 

Indicates a potential hazard or unsafe practice that, if not avoided, could result in minor 
personal injury or product/property damage. 

 

NOTE 

Provides application tips or other useful information to ensure that you get the most 
from your product. 
 

WARNING 

 

The device is intended only as an adjunct in patient assessment. It must be used in 
conjunction with clinical signs and symptoms. It is not intended as a device used for 
treatment purposes. 

 

To ensure patient safety, verify this device can function safely and normally before 

use. 

 

When using the device together with the electrical surgery equipment, the user 
should pay attention to and guarantee safety of the patient being measured. 

 

EXPLOSION HAZARD: Do not use the device in the presence of flammable anaesthetics, 

explosive substances, vapours or liquids. 

 

It is not recommended to hang the device when transporting patients. Safety hazards 
may arise from the large amplitude swing during the transportation. 

 

Do not use the device during MRl (magnetic resonance imaging) scanning because 

induced current could potentially cause burns. The device is capable of interfering 
with the proper performance of MRI, and MRI is capable of interfering with the 
measurement accuracy of the
 

 

The device may be contaminated by microorganism during transporting, use and 

storage. Use the recommended methods to sterilize and disinfect the device when the 
packing material is damaged, or it has not been used for a long time. 

 

The light (the red light and the infrared light which is invisible) emitted from the 
device is harmful to the eyes, so the user and the maintenance personnel can not 

stare at the light. 

Содержание V409

Страница 1: ...QAM V409 0616 4 V409 Fingertip Pulse Oximeter...

Страница 2: ......

Страница 3: ...ODUCTION 6 4 APPEARANCE AND DISPLAY 7 5 INSTALLATION 7 6 OPERATION 7 7 SpO2 MEASUREMENT 8 8 MAINTENACE 9 9 DISPOSAL 11 10 TROUBLESHOOTING 11 11 SPECIFICATIONS 12 Returns policy 13 Warranty 14 WARRANTY...

Страница 4: ...ides application tips or other useful information to ensure that you get the most from your product WARNING The device is intended only as an adjunct in patient assessment It must be used in conjuncti...

Страница 5: ...ry power It is compact tiny light low power consumption and easy for learning and handling It is suitable for monitoring adult and paediatric patients It is widely used in the hospital s operation roo...

Страница 6: ...Displays SpO2 pulse rate pulse bar graph and waveform 3 SpO2 waveform 4 Pulse bar graph Has 6 levels Indicates the pulse strength of SpO2 measurement 5 Clip press symbol Press here to open clip 6 Low...

Страница 7: ...ls as shown in figure 5 2 Cover the lid onto the cabinet and push it upwards to make it close well Figure 5 1 Battery Cabinet Figure 5 2 Installing Batteries CAUTION Use AAA alkaline batteries or rech...

Страница 8: ...r side The sensor measurement wavelengths are nominally 660nm for the Red LED and 940nm for Infrared LED Maximum optical power output for LED is 4 mW The amount of light transmitted depends on many fa...

Страница 9: ...ed into the device Placement of the device on the same extremity with a blood pressure cuff arterial catheter or intravascular line Loss of pulse signal can occur in the following situation The device...

Страница 10: ...the device can not be powered on or when powering on the battery capacity bar is 0 level or the low battery power indicator is red and flashes replace the batteries with good ones In case of any damag...

Страница 11: ...olluted by chemical substance the users should handle it effectively according to the properties of the chemical substance WARNING The cleaning solutions above can only be used for general cleaning If...

Страница 12: ...ettle the patient The device can not be turned on 1 The batteries are drained or almost drained 2 The batteries are not installed correctly 3 There is a problem with the device 1 Change batteries 2 Re...

Страница 13: ...cedure OTHER Any situation which is not covered by the above We will try to help but we cannot normally offer a refund DOA dead on arrival For additional clarification please refer to our terms and co...

Страница 14: ...aray s instructions Attachment of fittings and accessories not approved by Daray Repairs modifications carried out by service personnel not approved by Daray Damage caused by chemical corrosion from c...

Страница 15: ......

Страница 16: ......

Страница 17: ......

Отзывы: