16
Installation
Installation options
HCV 400 has an option for swapping the duct connections according to the description
in section “Product description” - “Overall description” . The current section will guide you
through the process of swapping the running mode between mode A and B .
Injury by electric shock and risk of damage to the device
• Always make sure the power is disconnected prior to disassembling the
unit and operating the mode selector switch .
The air ducts going into the house can either be connected on the right hand side or the left
hand side of the top of the unit . The default mode is mode A . If local systems demands mode
B, follow the below procedure AND check the label in order to connect the water drainage
correctly .
Follow these steps when swopping the mode:
Step Action
Illustration
1
Place new B-sticker on top of the
unit .
2
Remove the upper part of the
front cover .
3
Release the two screws at the up-
per left and right corner (under-
neath the upper part of the front
cover) .
4
Remove the remaining part of the
front cover .
5
Place new calibration sticker on
the heat exchanger .
6
Remove the cover of the main
PCB .
7
Switch A-B switch on the main
PCB to mode “B” .
Introduction
Warning
Caution
CAUTION
Selecting mode
Swopping to
mode B
Table continues on next page
1
4
5
2
3
A
B