background image

41071-1199 <90-00037>

 P

AGE

 13

INSTALLATION

1.

Slide a knife blade, thin screwdriver, or similiar tool carefully under

the lens between the case and the lens. Approximately 1/8" is suffi-

cient.

2.

Using a twisting motion, gently pry up on the lens until it pops off.

3.

Pull out the defective lamp.

4.

Insert new lamp.

5.

Press lens back on.
The lamps are type 48PSB and can be ordered from your local

electronics store or from Dantel using part number A25-00020-00.

OPERATION

T

o make sure the lamps and audible alarm are working, push

the AUDIO-VISUAL TEST button on the remote switch box.

To enable the audible alarm, put the ON/ACO switch on the

remote switch box in the ON position.
To disable the audible alarm, put the ON/ACO switch in the

ACO position.
To adjust the volume of the audible alarm, turn the screw on the

right side of the alarm display box.

TECHNICAL SPECIFICATIONS

DESCRIPTION

Input Voltage
Relay Coil

Nominal Power

Resistance
Relay Contact Current Rating

Physical Dimensions

Alarm Display Box
Remote Switch Box

Wire Wrap Pin Dimensions

Diameter
Length

Weight

VALUE

-48 VDC

518 - 580 mW

1070 ohms +/-10%

2 Amps (maximum)

7.9"H x 4.7"D x 3.5"W

2.6"H x 1.4"D x 2"W

0.045" square

3/4"

2 lbs.

Содержание B23-41071

Страница 1: ...lete information on electrostatic discharge safety precautions refer to BellcoreTM Technical Reference TR NWT 000870 Copyright 1999 by Dantel Inc Dantel is a registered trademark of Dantel Inc ISO 900...

Страница 2: ...e switch box is in the ON position You can change the alarm volume by adjusting a screw on the right side of the display box When the ON ACO switch is in the ACO Alarm Cut Off posi tion the audible al...

Страница 3: ...ON ACO switch is in the ON position You can change the alarm volume by adjusting a screw on the right side of the display box When the ON ACO switch is in the ACO Alarm Cut Off position the audible al...

Страница 4: ...4 41071 1199 90 00037 CIRCUIT DESCRIPTION FIG 1 SCHEMATIC 41071 ALARM DISPLAY UNIT ALARM INPUTS P W B A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18...

Страница 5: ...and the switch box at floor level The 41071 Alarm Display Unit can be used with the following devices MULTIPLEALARM TRANSMITTERS MATS Inputs to the Alarm Display Unit can come from the A through D ala...

Страница 6: ...Processor MAP To report all four alarm levels A B C D you need two SAAMs Refer to Fig 3 FIG 3 TYPICAL RELAY CONNECTIONS 46017 SUMMARY AUDIBLE ALARM MODULE SUMMARYALARMMODULE Dantel s 46019 Summary Ala...

Страница 7: ...use this application you can connect the outputs of the CPMs to the Alarm Display Unit s inputs for alarm indication Refer to Fig 5 APPLICATION INFORMATION A 40 42 39 K1A K1B B 44 43 51 K2A K2B 9 5 K3...

Страница 8: ...K2B K2A K1A K1B 48 VDC CONTROL OUTPUT 46028 AND 46029 CONTROL POINT MODULES 4 3 6 5 8 7 12 11 10 9 14 13 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 1 2 X 1 X 2 X 3 X 4 X 5 X 6 X 7 X 8 X 9 X 10 X...

Страница 9: ...PICAL RELAY CONNECTIONS 46001 STATUS MONITOR APPLICATION INFORMATION GLOBAL VISUAL LOCAL VISUAL AUDIBLE 48 VDC K3B 48 VDC K3A 41071 ALARM DISPLAY UNIT K2B K2A K1A K1B 48 VDC 1C 1D 2E 2F 4A 4B MINOR AL...

Страница 10: ...ire to pin 2 of SW1 White orange wire to pin 3 of SW1 White green wire to pin 4 of SW1 Green white wire to ground pin 48V White blue wire is not used To install the 41071 Alarm Display Unit refer to F...

Страница 11: ...d middle PCBs Jumper the cathode non numbered side of these diodes to gether Wire one cathode to K2A on the bottom PCB Wire the ground outputs from the relays of the MATs SAAMs SAMs or CPMs that will...

Страница 12: ...ay Unit follow these steps 1 Apply power to the unit Make sure the ON ACO switch on the remote switch box is in the ON position 2 Push the AUDIO VISUAL TEST button on the remote switch box In proper o...

Страница 13: ...udible alarm are working push the AUDIO VISUAL TEST button on the remote switch box To enable the audible alarm put the ON ACO switch on the remote switch box in the ON position To disable the audible...

Страница 14: ...n instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respect...

Отзывы: