04649-1098 <90-00194>
P
AGE
3
INSTALLATION
T
his section consists of:
♦
Equipment mounting
♦
Wiring
♦
Switch and strap settings
4003c Line Amplifier
44202 202-Compatible Modem
♦
Alignment and Checkout Procedure
E
QUIPMENT
M
OUNTING
Install the shelf in an equipment rack using the hardware pro-
vided. Refer to Fig. 1. Install the shelf as explained below.
Tools Required:
♦
Phillips screwdriver
♦
3/8 hex nut driver
1. Check the mounting brackets.
The brackets are installed at the factory so the front of the shelf
extends forward from the equipment rack. You can remove the
brackets and reinstall them for flush mounting. To install the
shelf in a 23-inch rack, remove the brackets and install the
optional mounting brackets that are in a parts bag attached to the
unit.
2. Install the shelf.
Install the shelf in the equipment rack, using the hardware
supplied in the parts bag. Refer to Fig. 1 in conjunction with the
following steps.
1.
Facing the frame rail, place the shelf in the rack. Secure the shelf
with three Phillips-head screws and lock washers - two on the right
side at the top and bottom, and one on the lower left side.
2.
Install one ESD stud with lock washer in the upper left location.
3.
Secure all fasteners tightly, ensuring proper grounding between the
ESD stud and the frame rail.
4.
Place an ESD label next to the ESD stud.
5.
From the rear of the bay, install the other ESD stud into the frame
rail next to the shelf. Secure tightly, ensuring proper grounding be-
tween the ESD stud and the frame rail.
6.
Place an ESD label next to the ESD stud.