Dantel B15-00459-02 Скачать руководство пользователя страница 29

05725-02-0499 <90-00201>

 P

AGE

 29

T

he following is a step-by-step procedure for turning up the shelf

after it has been mounted in the equipment bay, all wiring has

been made, and all switches and straps have been set.

NOTE: All switches have been set at the factory for the default setting.

The only changes to the switch settings are the setting of the

E-System Adapter address, the configuration of alarm point

level indicators, if they are required, and the setting of the MAP

memory (switch 5 position 7 to ON) after configuration is

complete.

S

TEP

 1-I

NSERT

 M

ODULES

 

AND

 C

ONNECT

 

THE

 I

NTERFACE

 C

ABLES

(See DJ05725 for simple block drawing and how to connect cables)

1.

Install all modules in the shelf starting with Slot 1 through slot 11.

Refer to the B18-05725-XX Block and Level Drawing page 3 for Mod-

ule slot assignments.

2.

Make power and ground connections to the B18-05725 shelf using

barrier strip B1 for the A battery feed and barrier strip B2 for the

B battery feed, if redundant battery is provided. Ground is connected

to barrier strip terminal B3.

3.

Use the DJ05725 drawing sheets 2 and 3 as references, and connect

the 929-00062-00 DB 15 M/M cables between C1 and C2 and the fiber

optic terminals.

4.

Mount the A25-00710-00 frame block on a frame or use the

A25-00508-01 23" Block mounting bar to mount the cross connect

block on, and mount the mounting bar in the relay rack where the

cross connects will take place.

5.

Connect the four 50 pin connector cables, A26-49029-25, between the

A25-00710-00 cross connect block and the B18-05725 assembly. C1,

C2, C3 and C4 of the B18-05725 assembly and A, B, C, and D of the

cross connect block.

6.

When the fuse module is inserted into slot 12 power will be applied to

the shelf.

S

TEP

 2 - S

ET

 L

EVELS

The levels that are used by the modem are -29 dBm XMT and

-6 dBm RCV. This should always apply since all shelves will be

equipped with the Tellabs 4003C card.
The data levels at the 46105 will be -29 dBm XMT (into the 46105)

and -6 dBm RCV (out of the 46105). Refer to Fig 16.
The over-all system levels can be verified by injecting a terminated

-16 dBm, 1 kHz test tone at the far end 46105 XMT drop jack and

measuring the local 46105 RCV drop jack at +7dBM, terminated.

If the signal is not 1 dB of the required RCV test tone

TURN-UP PROCEDURE

N

OTE

:

All switches, straps, and lev-

el adjustments are factory-

set. Refer to the B18-05725

Block and Level Drawing

and circuit order card, if ap-

plicable for standard levels.

CONTINUED

 . . .

Содержание B15-00459-02

Страница 1: ...a banner in the right margin UPDATED Table of Contents Ordering Information 2 General Description 2 Installation 5 Turn Up Procedure 29 Support Documentation 41 Warranty 42 xmt out loop mon 4003C line...

Страница 2: ...drawing that accompanies this Application Manual The 02 option is equipped with a 46105 Dual VF 64 kilobit Chan nel Module The output of this shelf is a digital signal that can be transmitted over a...

Страница 3: ...ster Port is used to report the alarm information to the alarm center through the E System Adapter The Master Port provides mounting for the RS 232 subassem bly E System Adapter ESA slot 8 The ESA pro...

Страница 4: ...A B C D 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 A B C D A1 A2 RST ACK A1 ON XMT DATA RCV DATA 46009 0X 32 POINT TRANSMITTER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 A B C D 1 2 3 4 5 6 7 8 9 10 11 12 13...

Страница 5: ...labs 4003C 46105 Dual VF 64 kilobit Channel 46019 Summary Alarm Module 48001 Fuse Module 4 Summary of Switch Settings EQUIPMENT MOUNTING Tools Required Ohmmeter Phillips screwdriver 7 16 Nutdriver or...

Страница 6: ...1 25 1 16 TB 1 16 TB 15 30 15 30 C1 C2 C3 C4 TB 1 2 3 4 5 6 7 8 9 10 A B E F C5 C6 C7 C8 C1 C2 C3 C4 PANEL D PANEL C PANEL B PANEL A DC GND 1 1 1 1 1 25 50 26 XMIT REC LINE ZAET Circuit LIST 13 CABLS...

Страница 7: ...frame rail 4 Place ESD label next to the ESD stud 5 From the rear of the bay install the other ESD stud and lockwasher into the frame rail next to the equipment shelf Secure tightly ensur ing proper...

Страница 8: ...C 2D 3A 3B 3C 3D CPM TB A 5B 5D 5A 5C 29 30 MAT MAT WIRING ADDED WHEN PANEL IS NOT EQUIPPED WITH A MAC CARD 1 2 3 4 5 6 7 8 9 1 0 A B C D E F TB A T E R M I N A L S T R I P B A C K P L A N E I N P A N...

Страница 9: ...46009 Multiple Alarm Transmitter MAT Refer to Fig 5 and Table A FIG 5 46009 MAT SWITCH AND STRAP LOCATIONS INSTALLATION 1 2 3 4 1 2 3 4 5 6 7 8 1 2 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 BOTTOM EDGE S5 S4 S...

Страница 10: ...that the switch is down down ON DCM addresses 17 18 display 5 bits 1 32 DCM addresses 19 20 display 5 bits 33 63 NOTE The MATs in slots 1 and 2 are not interchangeable without changing the address on...

Страница 11: ...3 4 5 6 7 8 1 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 Leave in NORM Leave in A position 46020 38 Multiple Alarm Processor MAP Refer to Figs 7 and 8 and Tables C and D FIG 7 46020 MAP SUBASSEMBLY AND SWITCH LOCA...

Страница 12: ...n remove power and place switch 5 position 7 DOWN This will retain the configuration in memory TABLE C SWITCHES 1 THRU 4 46020 38 SWITCH SW5 SW6 SW7 POSITION 1 2 3 4 5 6 7 8 1 1 1 1 1 1 0 1 1 1 1 1 1...

Страница 13: ...Normal Position TXD RXD RTS and DCD reversed CTSusedforhandshaking CTS not used for handshaking DCDusedforhandshaking DCD not used for handshaking ParallelOption YES NO SWITCH OR STRAP SETTINGS S1 00...

Страница 14: ...Table F 1 0 1 0 0 0 0 0 0 1 1 1 1 1 1 1 NOTE A 1 indicates that the rocker switch is up adjacent to the position number open OFF A 0 indicates that the rocker switch is down adjacent to the position...

Страница 15: ...1 0 0 0 0 0 0 0 1 0 0 1 0 0 0 0 1 0 1 0 0 0 0 0 1 0 1 1 0 0 0 0 1 1 0 0 0 0 0 0 1 1 0 1 0 0 0 0 1 1 1 0 0 0 0 0 1 1 1 1 0 0 0 1 0 0 0 0 0 0 0 1 0 0 0 1 0 0 0 1 0 0 1 0 0 0 0 1 0 0 1 1 0 0 0 1 0 1 0 0...

Страница 16: ...0 0 1 0 0 1 0 0 0 1 0 0 0 1 0 0 0 1 1 0 0 1 0 0 1 0 0 0 0 1 0 0 1 0 1 0 0 1 0 0 1 1 0 0 0 1 0 0 1 1 1 0 0 1 0 1 0 0 0 0 0 1 0 1 0 0 1 0 0 1 0 1 0 1 0 0 0 1 0 1 0 1 1 0 0 1 0 1 1 0 0 0 0 1 0 1 1 0 1 0...

Страница 17: ...0 1 1 0 1 0 1 1 1 0 0 0 1 0 1 1 1 0 1 0 1 0 1 1 1 1 0 0 1 0 1 1 1 1 1 0 1 1 0 0 0 0 0 0 1 1 0 0 0 0 1 0 1 1 0 0 0 1 0 0 1 1 0 0 0 1 1 0 1 1 0 0 1 0 0 0 1 1 0 0 1 0 1 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 1 0...

Страница 18: ...0 1 0 0 0 0 1 1 1 1 0 0 0 1 0 0 0 1 0 0 0 1 0 0 1 1 0 0 0 1 0 1 0 1 0 0 0 1 0 1 1 1 0 0 0 1 1 0 0 1 0 0 0 1 1 0 1 1 0 0 0 1 1 1 0 1 0 0 0 1 1 1 1 1 0 0 1 0 0 0 0 1 0 0 1 0 0 0 1 1 0 0 1 0 0 1 0 1 0 0...

Страница 19: ...0 1 0 1 1 0 0 1 1 1 0 1 1 0 1 0 0 1 0 1 1 0 1 0 1 1 0 1 1 0 1 1 0 1 0 1 1 0 1 1 1 1 0 1 1 1 0 0 0 1 0 1 1 1 0 0 1 1 0 1 1 1 0 1 0 1 0 1 1 1 0 1 1 1 0 1 1 1 1 0 0 1 0 1 1 1 1 0 1 1 0 1 1 1 1 1 0 1 0 1...

Страница 20: ...0 1 1 1 1 1 1 1 1 0 0 0 0 0 1 1 1 0 0 0 0 1 1 1 1 0 0 0 1 0 1 1 1 0 0 0 1 1 1 1 1 0 0 1 0 0 1 1 1 0 0 1 0 1 1 1 1 0 0 1 1 0 1 1 1 0 0 1 1 1 1 1 1 0 1 0 0 0 1 1 1 0 1 0 0 1 1 1 1 0 1 0 1 0 1 1 1 0 1 0...

Страница 21: ...e only TABLE G CONTINUED 46033 E SYSTEM ADAPTER S2 SWITCH SETTINGS 49013 202 Tone Modem Subassembly Refer to Fig 11 and Table H for switch and strap settings FIG 11 49013 202 TONE MODEM SWITCH AND STR...

Страница 22: ...ON S2 OFF 1 2 1 2 3 4 OFF 5 Transmit and Receive channel level switches are located on front panel Note that the settings shown are factory settings Change per Engineer s instructions IN IN 1 2 4 8 1...

Страница 23: ...FF 1 ON refer to Table J OFF ON FRONT PANEL LEVEL SWITCHES XMT 0 dB refer to Fig 12 RCV 0 dB refer to Fig 12 TABLE I 4003C SWITCH OPTIONS TABLE J 4003C LOOPBACK FREQUENCY SELECTION S13 FREQUENCY 2813H...

Страница 24: ...L TM T T TM T T TERM RPTR S101 S2 S1 T T L T E R M RCV DATA T T L T T L T E R M RCV CLK T T L T T L T E R M XMT CLK Y E S N O M LEAD N C N D E LEAD 46105 Dual VF 64 Kilobit Channel Refer to Fig 13 and...

Страница 25: ...is TTL compatible pin 44 is not used 180 ohm termination across RS 422 inputs at pins 5 and 6 XMT CLK 2 pin 5 is TTL edge compatible pin 6 is not used XMT CLK 2 pin 6 is TTL edge compatible pin 5 is...

Страница 26: ...to scale SWITCH 1 2 3 4 POSITION ON Timeout 0 5 min ON Timeout 1 0 min ON Timeout 4 0 min ON Timeout 8 0 min Setting for this application All switches OFF no timeout Only one switch may be on at a ti...

Страница 27: ...01 01 REV __ Alarm 1 2 3 4 5 6 7 8 9 10 11 12 JP1 1 2 3 POSITION Pins 1 2 Pins 2 3 DESCRIPTION RedundantorSingleInput TwoIndependantInputs Setting for this application 48001 Fuse Module Refer to Fig 1...

Страница 28: ...inter syntax 9600 baud master port set for DCP protocol address 1 E system mode on 1200 baud data port set for 9600 baud DCM protocol no TBOS S1 set for 00 normal mode CTS not used X1 on DCD not used...

Страница 29: ...0062 00 DB 15 M M cables between C1 and C2 and the fiber optic terminals 4 Mount the A25 00710 00 frame block on a frame or use the A25 00508 01 23 Block mounting bar to mount the cross connect block...

Страница 30: ...k These levels need not be changed unless they are not within the 1 dB tolerance but they should be verified on the routine level maintenance schedule FIG 16 TONE LEVELS CONTINUED Dantel TELLABS 4003C...

Страница 31: ...be required to verify suspected bad modules or to set levels on modules that have been swapped out SLOTS 1 AND 2 MULTIPLE ALARM TRANSMITTER MAT NOTE Slots 3 and 4 are wired only and not equipped The...

Страница 32: ...Z D 4 TELLABS 4003C 46020 40 XMT DATA 49029 00 RS232 XMT DATA RCV DATA RTS DCD DTR CTS Not Used LEDs will be on 46105 XX DUAL VF 64B CHAN XMT 46105 XX RCV SYNC RCV LVL GND XMT RCV SYNC RCV LVL GND Syn...

Страница 33: ...to 64 and observe the MAT alarm LEDs The corresponding LED on the MAT should light up whenever the alarm input of the A25 00710 00 block is grounded MAT 1 is for alarm inputs 1 to 32 and MAT 2 is for...

Страница 34: ...o the CPM and that all of the points are now released This will turn off all control points 5 Observe the CPM LEDs from 1 through 16 they should now be off 6 Use the ohmmeter again and check all contr...

Страница 35: ...ace the MAP with a 49029 subassem bly on it with a known good one that has the switches set cor rectly per the Tables Changing Default Alarm Levels All alarms default to a D level If it is necessary t...

Страница 36: ...To see if the devices are correctly loaded type MAT MAT address SHOW Or in this case MAT 5 SHOW The MAT level assignment will come back as follows MAT 5 OPTIONS A A A A A A A A A A A A A A A A NOTE A...

Страница 37: ...een changed during shipment NOTE The following steps should be only be used to verify the level settings They should only be required if modules are swapped or to test suspected bad modules 1 Using a...

Страница 38: ...e used to only verify the level settings They should only be required if modules are swapped out or to test suspected bad modules 1 Refer to Fig 4 and set the bridge terminal switch to terminal Set th...

Страница 39: ...ated 1 kHz signal into the DROP XMT jack for channel 2 on the front panel of the 46105 module 16 Verify with the dB meter not terminated a level of 0 dB at both XMT LVL test point jacks for channel 1...

Страница 40: ...5 Replace the blown fuse with a good one the short should be removed and the LED should be off GENERALTROUBLESHOOTING If difficulties are experienced with this unit check the following as appropriate...

Страница 41: ...DANTEL Included in this section 46020 38 Installation and Operation Manual B18 05725 XX Block and Level Drawing DJ 05725 Ordering Guide an RMA number Include a description of the malfunction with the...

Страница 42: ...en instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respec...

Отзывы: