![Dantel 49213 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/dantel/49213/49213_installation-and-operation-manual_3465864007.webp)
49213-1297 <90-00094>
P
AGE
7
Side
View
Closed
To open front panel
for access to wire
wrap pins, lift up
on the tabs on the front
panel. The panel
will swing forward.
Side
View
Open
462xx-xx REV ____
WARNING:
REMOVE fuse
before removing
or inserting module
Use wrist strap
ESD SENSITIVE DEVICE
POWER
ALARM
uP LED
MSTR
AUX
GREEN = RCV
RED = XMT
Front View
NOTE
: Check the transmit level without making adjustments by
shorting pins R and S of column 32.
F
IG
. 6 - O
PENING
P
LASTIC
C
OVER
INSTALLATION
TECHNICAL SPECIFICATIONS
DESCRIPTION
Input Voltage
Max. Input Current
+5 VDC
-5 VDC
Max. Heat Dissipation
+5 VDC
-5 VDC
Data Rate
Transmit Output Level Range
Receiver Sensitivity with
Frequency Dev16 Hz
Operating Frequencies
Mark
Space
Temperature Range
Physical Dimensions
Weight
DESCRIPTION
+5 VDC and -5VDC (from host)
150 mA
30 mA
2.6 Btu/Hr
0.5 Btu/Hr
Up to 1200 Baud
-1 to -20 dBm/-20 to -40 dBm (600 ohms)
+1 dBm to -47 dBm
1200 Hz
2200 Hz
0° to 55° C.
3.2" x 2.0" x 0.5"
1.5 ounces