![Dantel 49013 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/dantel/49013/49013_installation-and-operation-manual_3469967009.webp)
49013-1297 <90-00034>
P
AGE
9
OPERATION
TECHNICAL SPECIFICATIONS
T
he 49013 202 Tone Modem Subassembly starts normal
operation as soon as power is applied by way of the host
module. Place the front panel switch in the TEST position as
required to verify that the data transmission circuits are func-
tioning.
The green LED labeled CD (Carrier Detect) on the front panel of
the 49013 indicates that received data carrier is active.
DESCRIPTION
Input Voltage
Nominal Current
(Add to host module’s specs)
Heat Dissipation
(Add to host module’s specs)
Data Rate
Input Level Range
Output Level Range
Operating Frequencies
Mark
Space
Operating Temperature Range
Physical Dimensions
Weight
VALUE
-12 and +5 VDC (from host module)
11 mA @ -24 VDC
6 mA @ -48 VDC
0.99 Btu/Hr @ -24 VDC
0.98 Btu/Hr @ -48 VDC
1200 baud
0 to -20 dBm/ -20 to -40 dBm
-1 to -20 dBm/ -20 to -40 dBm
1200 Hz
2200 Hz
0° to 55° C.
2.6" x 2.8" x 0.8"
1.75 ounces