32
The following table shows the action taken for various Aux connection patterns in the various Aux
port modes:
AUX X
AUX Y
2+Mute ACTION
(State or Event)
3 Snaps ACTION
(State or Event)
4 Snaps ACTION
(State)
3+Mute ACTION
(State)
Open
Open
No Change
No Change
Recall Snapshot 1
Recall Snapshot 1
Gnd
Open
Recall Snapshot 1
Recall Snapshot 1
Recall Snapshot 2
Recall Snapshot 2
Open
Gnd
Recall Snapshot 2
Recall Snapshot 2
Recall Snapshot 3
Recall Snapshot 3
Gnd
Gnd
Mute
Recall Snapshot 3
Recall Snapshot 4
Mute
Some of the above modes allow the AUX Port to be used either in
Event
mode (whereby a
momentary push-button or momentary relay contact closure on one of the AUX lines will cause a
Snapshot to be recalled). Or in
State
mode (where a rotary switch etc. connected to both of the AUX
lines selects which Snapshot to use).
Some of the other modes only allow
State
mode, requiring the connection pattern to persist in order
for the Snapshot to be held as the current one.
NOTE: That if the contact closure port is being driven, or if the Aux Style is set to one of the
State
modes, this will override the snapshot recall setting in the menu (or in System Engineer). Also
under these conditions, the snapshot menu items are not accessible, and the Home screen will
show the Snapshot number as a reminder.