This product conforms to BS EN 60669-2-1 and BS EN 55015.
Please ensure the most recent edition of the appropriate local wiring regulations are observed 

and suitable protection is provided e.g. a 10 amp circuit breaker and voltage surge protection.  

Please ensure that this device is disconnected from the supply if an insulation test is made. 
This product is covered by a warranty which extends to 5 years from the date of manufacture.

Precautions and Warranty 

  Dusk Switch
 

DUSW with Intelligent photocell

DANLERS  DUSW  is  IP66  rated  and  can  be  surface  mounted  onto  an 

external wall. It will switch outdoor lights on at dusk and switch them off after 

a  chosen  time  delay  or  when  it  becomes  light  again,  repeating  each  day. 

The light level at which the lamp will switch on and off is set by a lux adjuster. 

DUSW  has  a  new  ‘intelligent’  calibration  process  which  will  remove  the  site 

specific addition of artificial light from any decision to switch the lights on/off.” 

Loading

The switch should only be connected to a 230V 50Hz AC supply. These PIR 

switches can switch up to:
6 amps (1500W) of resistive loads.
6 amps (1500W) of fluorescent loads.
3 amps (750W) of electronic and wire wound transformer loads.
2 amps (500W) of CFL, 2D lamps, LED Drivers and LED lamps and fittings.
1 amp (250W) of fans
Minimum load 2W resistive, suitable for most energy saving lamps, LEDs and 

emergency fittings.

Installation procedure

1.    Please read these notes carefully before commencing work.  

In case of doubt please consult a qualified electrician.

2.    The switch should be sited such that it can receive more daylight than 

artificial light. Ensure that any artificial lights are not too close to the switch or 

shining into it.

3.    The switch must be mounted via the four pre-formed holes only, no 

additional holes should be drilled through the enclosure. The spindle must 

point downwards, with room below to adjust it.

4.    Make sure the power is isolated from the circuit.
5.    The detector should be connected as shown in diagram D.
     L - Live in, N - Neutral in, SL - Switched Line out.
6.    IMPORTANT - Replace terminal cover.
7.    Once the wiring has been completed and verified, switch on the supply and 

test the operation.

11/12/15

INS972 DUSW

Variants

Low voltage variants can be supplied, coded by the following suffixes:
• 12VAC  

12V - (ac supply) operation

• 12VDC  

12V - (dc supply) operation

• 24VAC  

24V - (ac supply) operation

• 24VDC  

24V - (dc supply) operation

Variants with bespoke timings can be manufactured to special order.

Trouble shooting

 
The lamp switches off about 1 minute after it switches on. 

• Unit has not been calibrated 

• Too much artificial light is entering the DUSK Switch.

The lamp switches on too early in the evening. 

• Move the Lux adjuster further towards clockwise.

The lamp switches on too late in the evening. 

• Move the lux adjuster further anticlockwise.

If the LED fails to illuminate (after calibration) either RED or Green and the 

load switches on (after a minute), the current ambient lux is lower than the 

minimum 10 Lux (at the cell) and the switch cannot be inhibited off. 

• Site the DUSW in a position that sees more natural light.