3
4
Automatic Squelch
3.
Channel selection
4.
All channels can be selected by channel selector keys (8) [
] or (9) [
].The selected channel is displayed on the LCD. In
communication both transceivers (the receiving and transmitting party)
need to be in the same channel and under same modulation type.
Modulation MODE selection
5.
This key (6) [AM/FM] allows selecting the AM or FM modulation.
Your modulation mode has to correspond to the one of your
correspondent.
With the version Full Multi Norm in the norm UK, you can switch
between the E.band and the UK band, which is indicated by
symbol "E" or "UK", by pressing the key (6) [AM/FM].
The CB band E consists of the 40 CEPT channels. The CB
band UK consists of 40 channels starting from 27.60125 MHz to
27.99125 MHz.
The automatic squelch (ASQ ) uses a preset average value. It can
be activated by short key (5) [ ASQ ], The automatic squelch mode
(AQ icon) is indicated on the LCD.
Manual Squelch
2.
Turn the SQ knob (2) clockwise to the exact point where all
background noise disappears. Please note that this control is
fine regulation, if you set this SQ control to the maximum (fully
clockwise), the radio can only receive the strongest signal.
D 80 FM (26.565 - 27.405 MHz), 4 W
40 AM (26.965 - 27.405 MHz), 1W.
EU 40 FM (26.965 - 27.405 MHz), 4 W
40 AM (26.965 - 27.405 MHz), 1W.
EC 40 FM (26.965 - 27.405 MHz), 4 W.
UK 40 FM (27.60125 - 27.99125 MHz), 4 W
40 FM (26.965 - 27.405 MHz), 4W.
PL 40 FM (26.960 - 27.400 MHz), 4 W
40 AM (26.960 - 27.400 MHz), 4W.
E 40 FM (26.965 - 27.405 MHz), 4 W
40 AM (26.965 - 27.405 MHz), 4W.
US 40 AM (26.965 - 27.405 MHz), 4W.
NZ 40 FM (26.330 - 26.770 MHz), 4 W
40 AM (26.330 - 26.770 MHz), 4W.
To change current norm, please hold the key (6) [AM/FM ] while
turning the radio on. In the display, the symbol of the current norm
appears, please select the norm by pressing the channel selector
key(8) [
] or (9) [
]. To verify your selection, turn the
radio off and on again, the radio automatically returns to the
selected operation mode.
HOW TO USE YOUR CB RADIO
ON/OFF-Volume
1.
a)To turn the set on, turn the knob (1) clockwise.
b)To increase the sound level, turn the same knob further clockwise.
Note:
The E norm is internally set to 40 channels FM+AM, 4
Watts only.
Automatic Scanning
7.
Press the key (10) [SC] to enable the SCAN function. Before
enabling the SCAN function, firstly turn the SQ control clockwise
till the background noise is cut out. Then press the key (10) [SC],
radio will automatically scan all channels and the SC icon will
appear on the LCD.
When a signal is detected on a channel, scanning stops on this
channel. You can receive the calling, and also, can transmit on
Norm Selection
6.
The version Full Multi Norm can be set by the user to the following
norms: