e
3
0
b
g
4
5
9
.1
0
Illustration 137: U
AUX
Connector
Table 137: Pin Assignment of U
AUX
Connector
Pins
(left to
right)
De‐
scrip‐
tion
Notes
Rating/parameter
1
24 V
AUX
Used for 24–48 V DC in-
put to the Power Supply
Module (PSM 510).
Nominal input voltage: 24 V/48 V DC ±10%
Nominal current: Depends on the number of servo drives in the application.
Maximum current: 50 A
Maximum cross-section: 16 mm
2
Maximum cable length: 3 m
Conductor cross-section range 0.75–16 mm
2
, solid or flexible (AWG 18–AWG 4)
2
GND
NOTICE
-
Only PELV potential can be connected to the U
AUX
input.
11.7.5.1 24/48 V Cable Cross Sections for PSM 510
Table 138: 24/48 V Cable Cross Sections for PSM 510
Minimum cable cross section for CE (minimum 70 °C, Cu)
16 mm
2
Minimum cable cross section for UL (minimum 60 °C, Cu)
4 AWG
11.7.6 LCP Connector (M8, 6-pole)
The LCP connector is located on the front of all the system modules. It used to connect the LCP directly via a cable.
Specifications
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170