9.3.81 P_STO error (0xFF85 / 0x120)
This error is valid for SDM 511/SDM 512.
Table 116: P_STO error (0xFF85 / 0x120)
Code
PROFINET
®
code
Name
Severity (warning/error/
trip lock)
Description
LCP name
0xFF85
0x120
P_STO error
Trip lock
P_STO voltage on the power card ex-
ceeds the limits.
P_STO error
9.3.82 Guide value reversed (0xFF90 / 0x121)
This error is valid for SDM 511/SDM 512.
Table 117: Guide value reversed (0xFF90 / 0x121)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0xFF90
0x121
Guide value re-
versed
Error
Position guide value went backwards
while the servo drive was in CAM
mode.
guide val rev
9.3.83 Guide value implausible (0xFF91 / 0x122)
This error is valid for SDM 511/SDM 512.
Table 118: Guide value implausible (0xFF91 / 0x122)
Code
PROFINET
®
code
Name
Severity (warning/error/
trip lock)
Description
LCP name
0xFF91
0x122
Guide value im-
plausible
Error
Increments between succeeding
values too large.
guide val impl
9.3.84 Sign of life error (0xFF95 / 0x14E)
This error is valid for SDM 511/SDM 512 with PROFINET
®
only.
Table 119: Sign of life error (0xFF95 / 0x14E)
Code
PROFINET
®
code
Name
Severity (warning/error/trip lock)
Description
LCP name
0xFF95
0x14E
Sign of life error
Error
Sign of life error.
SOL error
Diagnostics
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170| 191
Danfoss A/S © 2019.10
Содержание VLT MSD 510
Страница 1: ...Operating Guide VLT Multiaxis Servo Drive MSD 510 System...
Страница 2: ......