9.3.55 External position sensor error (0x7380 / 0x10D)
This error is valid for DAM 510 and SDM 511/SDM 512.
Table 90: External position sensor error (0x7380 / 0x10D)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x7380
0x10D
External position sensor
error
Error
External encoder data could
not be read.
ext sensor err
9.3.56 Following error (0x8611 / 0x10E)
This error is valid for SDM 511/SDM 512.
Table 91: Following error (0x8611 / 0x10E)
Code
PROFINET
®
code
Name
Severity (warning/error/trip
lock)
Description
LCP name
0x8611
0x10E
Following error
Warning, error
A following error has occurred.
following err
9.3.57 Homing error on entering homing mode (0x8693 / 0x10F)
This error is valid for SDM 511/SDM 512.
Table 92: Homing error on entering homing mode (0x8693 / 0x10F)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x8693
0x10F
Homing error on enter-
ing homing mode
Warning
Could not enter homing mode
(for example velocity not 0).
Homing mode
fail
9.3.58 Homing error on start homing method (0x8694 / 0x110)
This error is valid for SDM 511/SDM 512.
Table 93: Homing error on start homing method (0x8694 / 0x110)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x8694
0x110
Homing error on start
homing method
Warning
Could not start homing method
(for example drive not in stand-
still).
Homing meth-
od fail
9.3.59 Homing error distance (0x8695 / 0x111)
This error is valid for SDM 511/SDM 512.
Diagnostics
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170| 185
Danfoss A/S © 2019.10